Influence of shear stress on in-stent restenosis:: In vivo study using 3D reconstruction and computational fluid dynamics

被引:10
|
作者
Sanmartín, M
Goicolea, J
García, C
García, J
Crespo, A
Rodríguez, J
Goicolea, JM
机构
[1] Medtec Hosp Meixoeiro, Unidad Cardiol Intervencionista, Vigo 36200, Pontevedra, Spain
[2] Hosp Puerta Hierro, Unidad Hemodinam, Madrid, Spain
[3] Univ Politecn Madrid, ESII, Grp Mecan Fluidos, Madrid, Spain
[4] Univ Politecn Madrid, ESIC, Grp Mecan Medios Continuos, Madrid, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2006年 / 59卷 / 01期
关键词
restenosis; angioplasty; intravascular ultrasound; fluid dynamics;
D O I
10.1016/S1885-5857(06)60044-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives. Local factors may influence neointimal proliferation following conventional stent implantation. In this study, the relationship between wall shear stress and luminal loss after coronary stenting was assessed using a combination of angiography, intravascular ultrasound, and computational fluid dynamics. Patients and method. Seven patients with de novo right coronary lesions treated with conventional (i.e., bare metal) stents were included. Realistic three-dimensional geometric reconstructions were generated off line from angiographic and intravascular ultrasound data both immediately after stenting and at 6-month follow-up. A finite-volume model was used to calculate local wall shear stress within the stent and 4 mm proximally and distally to the stent. The mean coronary ostium entry flow velocity was assumed to be 25 cm/s in all cases. Results. The mean neointimal thickness was 0.29 (0.21) mm. In five cases, weak negative correlations between wall shear stress and neointimal thickness were found: maximum r value =-0.34, minimum r value =-0.11 (P <.001). The neointimal thickness in segments in which the level of wall shear stress was in the lowest quartile was greater than that in segments in which it was in highest quartile, at 0.34 (0.21) mm and 0.27 (0.24) mm (P <.001) for quartiles; 1 and 4, respectively. Conclusions. Low wall shear stress after stenting favors neointimal proliferation both within the stent and at the stent's edges.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 23 条
  • [1] Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
    John F LaDisa
    Lars E Olson
    Douglas A Hettrick
    David C Warltier
    Judy R Kersten
    Paul S Pagel
    BioMedical Engineering OnLine, 4
  • [2] Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
    LaDisa, John F., Jr.
    Olson, Lars E.
    Hettrick, Douglas A.
    Warltier, David C.
    Kersten, Judy R.
    Pagel, Paul S.
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [3] Carotid Geometry as a Predictor of In-Stent Neointimal Hyperplasia - A Computational Fluid Dynamics Study -
    Yao, Xinke
    Dai, Zhengze
    Zhang, Xu
    Gao, Jie
    Xu, Gelin
    Cai, Yan
    Li, Zhiyong
    CIRCULATION JOURNAL, 2019, 83 (07) : 1472 - +
  • [4] Analysis of wall shear stress in stented coronary artery using 3D computational fluid dynamics modeling
    Dehlaghi, Vahab
    Shadpoor, Mohammad Tafazoli
    Najarian, Siamak
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2008, 197 (1-3) : 174 - 181
  • [5] Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models
    LaDisa, JF
    Olson, LE
    Guler, I
    Hettrick, DA
    Kersten, JR
    Warltier, DC
    Pagel, PS
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 98 (03) : 947 - 957
  • [6] Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: Comparative study to 3D IVUS and 3D QCA
    Toutouzas, Konstantinos
    Chatzizisis, Yiannis S.
    Riga, Maria
    Giannopoulos, Andreas
    Antoniadis, Antonios P.
    Tu, Shengxian
    Fujino, Yusuke
    Mitsouras, Dimitrios
    Doulaverakis, Charalampos
    Tsampoulatidis, Ioannis
    Koutkias, Vassilis G.
    Bouki, Konstantina
    Li, Yingguang
    Chouvarda, Ioanna
    Cheimariotis, Grigorios
    Maglaveras, Nicos
    Kompatsiaris, Ioannis
    Nakamura, Sunao
    Reiber, Johan H. C.
    Rybicki, Frank
    Karvounis, Haralambos
    Stefanadis, Christodoulos
    Tousoulis, Dimitris
    Giannoglou, George D.
    ATHEROSCLEROSIS, 2015, 240 (02) : 510 - 519
  • [7] Location-Specific Comparison Between a 3D In-Stent Restenosis Model and Micro-CT and Histology Data from Porcine In Vivo Experiments
    P. S. Zun
    A. J. Narracott
    C. Chiastra
    J. Gunn
    A. G. Hoekstra
    Cardiovascular Engineering and Technology, 2019, 10 : 568 - 582
  • [8] Location-Specific Comparison Between a 3D In-Stent Restenosis Model and Micro-CT and Histology Data from Porcine In Vivo Experiments
    Zun, P. S.
    Narracott, A. J.
    Chiastra, C.
    Gunn, J.
    Hoekstra, A. G.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (04) : 568 - 582
  • [9] Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation
    John F. LaDisa
    Ismail Guler
    Lars E. Olson
    Douglas A. Hettrick
    Judy R. Kersten
    David C. Warltier
    Paul S. Pagel
    Annals of Biomedical Engineering, 2003, 31 : 972 - 980
  • [10] Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation
    LaDisa, JF
    Guler, I
    Olson, LE
    Hettrick, DA
    Kersten, JR
    Warltier, DC
    Pagel, PS
    ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (08) : 972 - 980