Rapid detection of total and viable Legionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry

被引:30
作者
Keserue, Hans-Anton [1 ,2 ,3 ]
Baumgartner, Andreas [2 ]
Felleisen, Richard [2 ]
Egli, Thomas [1 ,3 ]
机构
[1] Swiss Fed Inst Aquat Sci & Technol Eawag, CH-8600 Dubendorf, Switzerland
[2] Fed Off Publ Hlth FOPH, CH-3003 Bern, Switzerland
[3] ETH, Inst Biogeochem & Pollutant Dynam IBP, CH-8092 Zurich, Switzerland
关键词
IN-SITU HYBRIDIZATION; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; QUANTITATIVE DETECTION; GIARDIA-LAMBLIA; SPP; ENUMERATION; BACTERIA; CULTURE; SAMPLES;
D O I
10.1111/j.1751-7915.2012.00366.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We developed a rapid detection method for Legionella pneumophila (Lp) by filtration, immunomagnetic separation, double fluorescent staining, and flow cytometry (IMS-FCM method). The method requires 120?min and can discriminate viable and membrane-damaged cells. The recovery is over 85% of spiked Lp SG 1 cells in 1?l of tap water and detection limits are around 50 and 15 cells per litre for total and viable Lp, respectively. The method was compared using water samples from house installations in a blind study with three environmental laboratories performing the ISO 11731 plating method. In 53% of the water samples from different taps and showers significantly higher concentrations of Lp were detected by flow cytometry. No correlation to the plate culture method was found. Since also viable but not culturable (VNBC) cells are detected by our method, this result was expected. The IMS-FCM method is limited by the specificity of the used antibodies; in the presented case they target Lp serogroups 112. This and the fact that no Lp-containing amoebae are detected may explain why in 21% of all samples higher counts were observed using the plate culture method. Though the IMS-FCM method is not yet fit to completely displace the established plating method (ISO 11731) for routine Lp monitoring, it has major advantages to plating and can quickly provide important insights into the ecology of this pathogen in water distribution systems.
引用
收藏
页码:753 / 763
页数:11
相关论文
共 57 条
[1]   Longitudinal Evaluation of the Efficacy of Heat Treatment Procedures against Legionella spp. in Hospital Water Systems by Using a Flow Cytometric Assay [J].
Allegra, Severine ;
Grattard, Florence ;
Girardot, Francoise ;
Riffard, Serge ;
Pozzetto, Bruno ;
Berthelot, Philippe .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (04) :1268-1275
[2]   Use of Flow Cytometry To Monitor Legionella Viability [J].
Allegra, Severine ;
Berger, Francoise ;
Berthelot, Philippe ;
Grattard, Florence ;
Pozzetto, Bruno ;
Riffard, Serge .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (24) :7813-7816
[3]   Comparative assessment of virulence traits in Legionella spp. [J].
Alli, OAT ;
Zink, S ;
von Lackum, NK ;
Abu-Kwaik, Y .
MICROBIOLOGY-SGM, 2003, 149 :631-641
[4]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[5]   Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry [J].
Aurell, H ;
Catala, P ;
Farge, P ;
Wallet, F ;
Le Brun, M ;
Helbig, JH ;
Jarraud, S ;
Lebaron, P .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (03) :1651-1657
[6]  
BAG, 2012, MELD INF
[7]  
BAG, 2009, BER LEG LEG
[8]   Routine sampling and the control of Legionella spp. in cooling tower water systems [J].
Bentham, RH .
CURRENT MICROBIOLOGY, 2000, 41 (04) :271-275
[9]   Rapid, cultivation-independent assessment of microbial viability in drinking water [J].
Berney, Michael ;
Vital, Marius ;
Huelshoff, Iris ;
Weilenmann, Hans-Ulrich ;
Egli, Thomas ;
Hammes, Frederik .
WATER RESEARCH, 2008, 42 (14) :4010-4018
[10]   PRECISION AND ACCURACY OF RECOVERY OF LEGIONELLA-PNEUMOPHILA FROM SEEDED TAP WATER BY FILTRATION AND CENTRIFUGATION [J].
BOULANGER, CA ;
EDELSTEIN, PH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (05) :1805-1809