Real-time PC-based system for dynamic beat-to-beat QT-RR analysis

被引:8
作者
Govreen-Segal, D [1 ]
Radai, MM
Sivan, Y
Abboud, S
机构
[1] Tel Aviv Univ, Dept Biomed Engn, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Med Ctr, Dana Childrens Hosp, Pediat Intens Care Unit, IL-64239 Tel Aviv, Israel
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 1999年 / 32卷 / 04期
关键词
real-time ECG analyzer; QT and RR intervals; spectral analysis;
D O I
10.1006/cbmr.1999.1514
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A real-time analysis (RTA) system, based on a personal computer with a digital signal processor card (DSP) was developed. The system extracts and saves the QT and RR intervals from an incoming ECG signal sampled at 1 kHz. The method of defining the QT and RR intervals is based on performing multiple cross-correlations that enables rejection of artifacts from the analysis. The relationship between the RR and the Qr intervals is found using the following general formula QT(i) = cRR(i-1)(b). Linear regression is performed on the logarithms of QT and RR measurements obtained to estimate a constant (a = logc) and a slope (b), reflecting the dynamic change of the QT intervals. Having these two values, the dynamic QT extrapolated to a heart period of 1 s (QTcd) was calculated. The system also performs spectral analysis of the intervals and dynamic QT-RR relation-analysis. The system was evaluated oil recordings from 10 infants aged 4 to 24 weeks. The QT/RR computerized measuring device used in the present study answers to the requirements for precise dynamic beat-to-beat QT measurement. its sampling rate is high and can achieve a real millisecond-precision without the need of interpolation methods. The measurements are performed on-line, at the time of the actual recording. Results appear immediately and a measure of dynamic QT behavior can be easily obtained within minutes. The computerized system with the dynamic QT-RR measurements may provide a simple and accurate tool for testing drug treatment and effects of other interventions for cardiac disorders and arrhythmia risk. (C) 1999 Academic Press.
引用
收藏
页码:336 / 354
页数:19
相关论文
共 14 条
[1]   THE USE OF CROSS-CORRELATION FUNCTION FOR THE ALIGNMENT OF ECG WAVEFORMS AND REJECTION OF EXTRASYSTOLES [J].
ABBOUD, S ;
SADEH, D .
COMPUTERS AND BIOMEDICAL RESEARCH, 1984, 17 (03) :258-266
[2]   ERRORS IN THE VISUAL DETERMINATION OF CORRECTED QT (QTC) INTERVAL DURING ACUTE MYOCARDIAL-INFARCTION [J].
AHNVE, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (03) :699-702
[3]  
AHVNE S, 1982, CIRCULATION, V65, P435
[4]  
AHVNE S, 1985, AM HEART J, V109, P568
[5]  
*AR CORP, 1991, US MAN PC56 MOT DSP5
[6]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[7]   AN EFFICIENT ALGORITHM FOR SPECTRAL-ANALYSIS OF HEART-RATE-VARIABILITY [J].
BERGER, RD ;
AKSELROD, S ;
GORDON, D ;
COHEN, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (09) :900-904
[8]  
KAWATAKI M, 1982, JPN HEART J, V23, P570
[10]   NEW ALGORITHM FOR QT INTERVAL-ANALYSIS IN 24-HOUR HOLTER ECG - PERFORMANCE AND APPLICATIONS [J].
LAGUNA, P ;
THAKOR, NV ;
CAMINAL, P ;
JANE, R ;
YOON, HR .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (01) :67-73