Simultaneous assessment of endothelial function and morphology in the brachial artery using a new semiautomatic ultrasound system

被引:11
|
作者
Iguchi, Tomokazu [1 ]
Takemoto, Yasuhiko [1 ,2 ]
Shimada, Kenei [1 ]
Matsumoto, Kenji [1 ]
Nakanishi, Koki [1 ]
Otsuka, Kenichiro [1 ]
Hyodo, Eiichi [1 ]
Hirohashi, Kazuhiro [1 ,2 ]
Tahara, Akira [1 ,3 ]
Yoshiyama, Minoru [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Internal Med & Cardiol, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Grad Med Educ & Gen Practice, Osaka 5458585, Japan
[3] Asakayama Gen Hosp, Dept Internal Med & Cardiol, Osaka, Japan
关键词
brachial artery; flow-mediated dilatation; intima-media thickness; simultaneous automated measurements; INTIMA-MEDIA THICKNESS; WALL THICKNESS; CAROTID-ARTERY; RISK-FACTORS; CARDIOVASCULAR EVENTS; PREDICTIVE-VALUE; ATHEROSCLEROSIS; DILATION; DISEASE; VASODILATION;
D O I
10.1038/hr.2013.35
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The accuracy of measurements of the intima-media thickness (IMT) and flow-mediated dilatation (FMD) of the brachial artery made using a new semiautomated ultrasound system and the relationships among those parameters and the Framingham Risk Score (FRS) as a predictor of coronary heart disease (CHD) are unknown. We enrolled 70 subjects, including 47 patients with cardiovascular risk factors and 23 normal healthy volunteers. IMT and FMD were simultaneously measured using a new semiautomated ultrasound system, and the measurements were compared with those obtained manually as a reference standard (study 1). In addition, we enrolled 200 consecutive patients with risk factors but no CHD to examine the relationships among IMT, FMD and the FRS. The optimal cutoff values of FMD and IMT were determined in 200 patients without CHD, and the subjects were classified into four groups. The 10-year Framingham risks for each group were compared (study 2). FMD and IMT measurements made using the new semiautomated ultrasound system showed a good correlation with the measurements determined manually (study 1). Furthermore, FMD and IMT showed a significant correlation with the FRS. The 10-year Framingham risk was markedly higher in group D (FMD <5.5% and IMT >0.3 mm; 19.0 +/- 11.3%; study 2). In conclusion, the measurements made using a new semiautomated ultrasound system provided reliable and simultaneous evaluations of IMT and FMD. The combination of IMT and FMD measurements of the brachial artery may be beneficial for risk stratification of patients with cardiovascular risk factors but no CHD.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [21] Simultaneous Noninvasive Assessment of Systemic and Coronary Endothelial Function
    Iantorno, Micaela
    Hays, Allison G.
    Schar, Michael
    Krishnaswamy, Rupa
    Soleimanifard, Sahar
    Steinberg, Angela
    Stuber, Matthias
    Gerstenblith, Gary
    Weiss, Robert G.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (03)
  • [22] Effect of cardiac cycle on ultrasound assessment of endothelial function
    Chuang, ML
    Douglas, PS
    Bisinov, EA
    Stein, JH
    VASCULAR MEDICINE, 2002, 7 (02) : 103 - 108
  • [23] Ultrasound assessment of endothelial function in children
    Jarvisalo, Mikko J.
    Raitakari, Olli T.
    VASCULAR HEALTH AND RISK MANAGEMENT, 2005, 1 (03) : 227 - 233
  • [24] Brachial artery endothelial function predicts platelet function in control subjects and in patients with acute myocardial infarction
    Shechter, Michael
    Shechter, Alon
    Hod, Hanoch
    Fefer, Paul
    Shenkman, Boris
    Koren-Morag, Nira
    Feinberg, Micha S.
    Harats, Dror
    Sela, Ben Ami
    Savion, Naphtali
    Varon, David
    Matetzky, Shlomi
    PLATELETS, 2012, 23 (03) : 202 - 210
  • [25] Brachial Artery Wall Stiffness Assessment by Shear Wave Elastography: A Promising New Diagnostic Tool for Endothelial Dysfunction Detection
    Gulsen, Fatih
    Samanci, Cesur
    Durmaz, Emine Sebnem Memis
    Durmaz, Eser
    Tel, Cigdem
    Gencturk, Mert
    Agirman, Aysegul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (08) : 1977 - 1983
  • [26] Impaired endothelial function in patients with rapidly stabilized unstable angina:: Assessment by noninvasive brachial artery ultrasonography
    Esper, RJ
    Vilariño, J
    Cacharrón, JL
    Machado, R
    Ingino, CA
    Guiñazú, CAG
    Bereziuk, E
    Bolaño, AL
    Suarez, DH
    Kura, M
    CLINICAL CARDIOLOGY, 1999, 22 (11) : 699 - 703
  • [27] Limitations of non-invasive endothelial function assessment by brachial artery flow-mediated dilatation
    Sejda, T
    Pit'ha, J
    Svandová, E
    Poledne, R
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (01) : 58 - 61
  • [28] New device for assessment of endothelial function: plethysmographic flow-mediated vasodilation (pFMD)
    Kishimoto, Shinji
    Hashimoto, Yu
    Maruhashi, Tatsuya
    Kajikawa, Masato
    Mizobuchi, Aya
    Harada, Takahiro
    Yamaji, Takayuki
    Nakano, Yukiko
    Goto, Chikara
    Yusoff, Farina Mohamad
    Iwanaga, Yoshitaka
    Kanaoka, Koshiro
    Yada, Tomohiko
    Itarashiki, Tomomasa
    Higashi, Yukihito
    HYPERTENSION RESEARCH, 2024, 47 (09) : 2471 - 2477
  • [29] Estimation of viscoelasticity of radial artery via simultaneous measurement of changes in pressure and diameter using a single ultrasound probe
    Saito, Takumi
    Mori, Shohei
    Arakawa, Mototaka
    Ohba, Shigeo
    Kobayashi, Kazuto
    Kanai, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59
  • [30] Role of simultaneous carotid ultrasound in patients undergoing stress echocardiography for assessment of chest pain with no previous history of coronary artery disease
    Ahmadvazir, Shahram
    Zacharias, Konstantinos
    Shah, Benoy N.
    Pabla, Jatinder S.
    Senior, Roxy
    AMERICAN HEART JOURNAL, 2014, 168 (02) : 229 - 236