Simultaneous assessment of endothelial function and morphology in the brachial artery using a new semiautomatic ultrasound system

被引:11
|
作者
Iguchi, Tomokazu [1 ]
Takemoto, Yasuhiko [1 ,2 ]
Shimada, Kenei [1 ]
Matsumoto, Kenji [1 ]
Nakanishi, Koki [1 ]
Otsuka, Kenichiro [1 ]
Hyodo, Eiichi [1 ]
Hirohashi, Kazuhiro [1 ,2 ]
Tahara, Akira [1 ,3 ]
Yoshiyama, Minoru [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Internal Med & Cardiol, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Grad Med Educ & Gen Practice, Osaka 5458585, Japan
[3] Asakayama Gen Hosp, Dept Internal Med & Cardiol, Osaka, Japan
关键词
brachial artery; flow-mediated dilatation; intima-media thickness; simultaneous automated measurements; INTIMA-MEDIA THICKNESS; WALL THICKNESS; CAROTID-ARTERY; RISK-FACTORS; CARDIOVASCULAR EVENTS; PREDICTIVE-VALUE; ATHEROSCLEROSIS; DILATION; DISEASE; VASODILATION;
D O I
10.1038/hr.2013.35
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The accuracy of measurements of the intima-media thickness (IMT) and flow-mediated dilatation (FMD) of the brachial artery made using a new semiautomated ultrasound system and the relationships among those parameters and the Framingham Risk Score (FRS) as a predictor of coronary heart disease (CHD) are unknown. We enrolled 70 subjects, including 47 patients with cardiovascular risk factors and 23 normal healthy volunteers. IMT and FMD were simultaneously measured using a new semiautomated ultrasound system, and the measurements were compared with those obtained manually as a reference standard (study 1). In addition, we enrolled 200 consecutive patients with risk factors but no CHD to examine the relationships among IMT, FMD and the FRS. The optimal cutoff values of FMD and IMT were determined in 200 patients without CHD, and the subjects were classified into four groups. The 10-year Framingham risks for each group were compared (study 2). FMD and IMT measurements made using the new semiautomated ultrasound system showed a good correlation with the measurements determined manually (study 1). Furthermore, FMD and IMT showed a significant correlation with the FRS. The 10-year Framingham risk was markedly higher in group D (FMD <5.5% and IMT >0.3 mm; 19.0 +/- 11.3%; study 2). In conclusion, the measurements made using a new semiautomated ultrasound system provided reliable and simultaneous evaluations of IMT and FMD. The combination of IMT and FMD measurements of the brachial artery may be beneficial for risk stratification of patients with cardiovascular risk factors but no CHD.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 50 条
  • [1] Simultaneous assessment of endothelial function and morphology in the brachial artery using a new semiautomatic ultrasound system
    Tomokazu Iguchi
    Yasuhiko Takemoto
    Kenei Shimada
    Kenji Matsumoto
    Koki Nakanishi
    Kenichiro Otsuka
    Eiichi Hyodo
    Kazuhiro Hirohashi
    Akira Tahara
    Minoru Yoshiyama
    Hypertension Research, 2013, 36 : 691 - 697
  • [2] Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
    Alley, Hugh
    Owens, Christopher D.
    Gasper, Warren J.
    Grenon, S. Marlene
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (92):
  • [3] A New Noninvasive Method in Evaluating the Endothelial Function: The Measurement of the Resistive Index after Reactive Hyperemia of the Brachial Artery
    Korkmaz, Hasan
    Akbulut, Mehmet
    Ozbay, Yilmaz
    Koc, Mustafa
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (07): : 873 - 877
  • [4] Evaluation of endothelial function in patients with limited systemic sclerosis by use of brachial artery Doppler ultrasound
    Fernandes, Tatiana Melo
    Gomes Bica, Blanca Elena
    Villela, Nivaldo Ribeiro
    Salles, Elizabeth Figueiredo
    Leitao de Azevedo, Mario Newton
    de Souza Papi, Jose Angelo
    Gomes Martins, Rosangela Aparecida
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2012, 52 (04) : 554 - 568
  • [5] Measurement of brachial artery endothelial function using a standard blood pressure cuff
    Maltz, Jonathan S.
    Tison, Geoffrey H.
    Alley, Hugh F.
    Budinger, Thomas F.
    Owens, Christopher D.
    Olgin, Jeffrey
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (11) : 2247 - 2268
  • [6] Assessment of the endothelial function with changed volume of brachial artery by menstrual cycle
    Liu, Shing-Hong
    Wang, Jia-Jung
    Cheng, Da-Chuan
    Su, Chun-Hung
    Lin, Tzu-Hsin
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [7] The association between right coronary artery morphology and endothelial function
    Arbel, Yaron
    Dvir, Danny
    Feinberg, Micha S.
    Beigel, Roy
    Shechter, Michael
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 115 (01) : 19 - 23
  • [8] Effects of Hemodialysis on Brachial Artery Endothelial Function A Clinical Study
    Li, Xiang
    Li, Lina
    Fang, Shibao
    Xu, Yan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (11) : 1783 - 1787
  • [9] Ultrasound assessment of brachial endothelial vasomotor function in addition to carotid plaque echolucency for predicting cardiovascular events in patients with coronary artery disease
    Nakamura, Takamitsu
    Kitta, Yoshinobu
    Uematsu, Manabu
    Sugamata, Wataru
    Hirano, Mitsumasa
    Fujioka, Daisuke
    Sano, Keita
    Saito, Yukio
    Kawabata, Ken-ichi
    Obata, Jun-ei
    Kugiyama, Kiyotaka
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (02) : 555 - 560
  • [10] Comparison of Brachial Artery Wall Thickness Versus Endothelial Function to Predict Late Cardiovascular Events in Patients Undergoing Elective Coronary Angiography
    Suessenbacher, Alois
    Doerler, Jakob
    Wunder, Johannes
    Hohenwarter, Fabian
    Alber, Hannes F.
    Pachinger, Otmar
    Frick, Matthias
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (05): : 671 - 675