Evaluation of mixed mode solid phase extraction cartridges for the preconcentration of beta-lactam antibiotics in wastewater using liquid chromatography with UV-DAD detection

被引:118
作者
Benito-Peña, E [1 ]
Partal-Rodera, AI [1 ]
León-González, ME [1 ]
Moreno-Bondi, MC [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, Lab Opt Sensors, E-28040 Madrid, Spain
关键词
penicillins; multi-residue analysis; solid phase extraction (SPE); HPLC-UV-DAD; oasis MAX cartridge; wastewater;
D O I
10.1016/j.aca.2005.09.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple method has been developed for the simultaneous determination of beta-lactam antibiotics (BLAs) (penicillin G, amoxicillin, ampicillin, penicillin V, oxacillin, cloxacillin, dicloxacillin and nafcillin) in wastewater. The method is based on solid-phase extraction (SPE) and high performance liquid chromatography with UV-diode array detection (UV-DAD). Two SPE cartridges have been compared for sample clean up and preconcentration: a reversed-phase silica-based cartridge (Bond Elut C-18, Varian Inc.) and a strong polymeric mixed mode anion exchanger (Oasis MAX, Waters). The penicillins have been separated using a LUNA (TM) C-18 (2) (150 mm x 4.6 mm, 5 mu m) HPLC column and gradient elution with mobile phases consisting of aqueous trifluoroacetic acid and acetonitrile. The analytical wavelength was set at 220 nm. Under optimised conditions it was possible to preconcentrate up to 1000 mL of Milli-Q water in the Oasis MAX cartridges with recoveries in the range 82-97% (R.S.D. 2-9%) for all the antibiotic tested, except amoxicillin (52%, R.S.D. 8%), and limits of detection in the range of 8-24 ng L-1. The matrix components in industrial and urban wastewater samples reduce the preconcentration efficiency in both sorbents, especially for the Bond Elut C-18. The use of the Oasis MAX allowed detection limits between 2.9-25.6, 2.5-12.4 and 2.2-12.7 Rg L-1, when processing 250 mL of industrial, influent and effluent sewage treatment plant (STP) samples. Recoveries ranged between 46-91, 28-91 and 39-114% (industrial, influent and effluent STP, respectively) for samples spiked with all the antibiotics at 25 and 75 mu g L-1 (n = 3 for each level). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 36 条
  • [11] *EMEA, 1997, EMEACVMO936FINAL
  • [12] Determination of fluoroquinolone antibacterial agents in sewage sludge and sludge-treated soil using accelerated solvent extraction followed by solid-phase extraction
    Golet, EM
    Strehler, A
    Alder, AC
    Giger, W
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (21) : 5455 - 5462
  • [13] Trace determination of fluoroquinolone antibacterial agents in solid-phase extraction urban wastewater by and liquid chromatography with fluorescence detection
    Golet, EM
    Alder, AC
    Hartmann, A
    Ternes, TA
    Giger, W
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (15) : 3632 - 3638
  • [14] Occurrence, fate and effects of pharmaceutical substances in the environment - A review
    Halling-Sorensen, B
    Nielsen, SN
    Lanzky, PF
    Ingerslev, F
    Lutzhoft, HCH
    Jorgensen, SE
    [J]. CHEMOSPHERE, 1998, 36 (02) : 357 - 394
  • [15] Detection and identification of sulphonamide drugs in municipal waste water by liquid chromatography coupled with electrospray ionisation tandem mass spectrometry
    Hartig, C
    Storm, T
    Jekel, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 163 - 173
  • [16] Determination of antibiotics in different water compartments via liquid chromatography electrospray tandem mass spectrometry
    Hirsch, R
    Ternes, TA
    Haberer, K
    Mehlich, A
    Ballwanz, F
    Kratz, KL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 815 (02) : 213 - 223
  • [17] Simultaneous extraction of tetracycline, macrolide and sulfonamide antibiotics from agricultural soils using pressurised liquid extraction, followed by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Jacobsen, AM
    Halling-Sorensen, B
    Ingerslev, F
    Hansen, SH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1038 (1-2) : 157 - 170
  • [18] Determination of antibiotic substances in hospital sewage water using solid phase extraction and liquid chromatography/mass spectrometry and group analogue internal standards
    Lindberg, R
    Jarnheimer, PÅ
    Olsen, B
    Johansson, M
    Tysklind, M
    [J]. CHEMOSPHERE, 2004, 57 (10) : 1479 - 1488
  • [19] Analysis of trace levels of sulfonamide and tetracycline antimicrobials, in groundwater and surface water using solid-phase extraction and liquid chromatography/mass spectrometry
    Lindsey, ME
    Meyer, M
    Thurman, EM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (19) : 4640 - 4646
  • [20] MORIN RB, 1982, PENICILLINS CEPHALOS, V1