EFFECT OF GUIDE VANE ANGLE ON WELLS TURBINE PERFORMANCE

被引:0
|
作者
Haider, Paresh [1 ]
Samad, Abdus [1 ]
机构
[1] Indian Inst Technol Madras, Dept Ocean Engn, Madras 600036, Tamil Nadu, India
来源
PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2014 | 2014年
关键词
Wells turbine; Tip clearance; Guide vane; Wave energy conversion; Axial flow turbine; TIP CLEARANCE; HYSTERETIC CHARACTERISTICS; NUMERICAL-SIMULATION; AIR TURBINE;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Wells turbines are used in oscillating water column wave energy system and the turbine has a stagger angle of 90 degrees. Numerical analysis is performed to analyze the performance of the turbine in the present work. A commercial code ANSYS-CFX (R) v14.0 was used for the simulations at different flow coefficient, different angles and a constant rotational speed. The turbulence model was k-omega SST. Higher guide vane angle produced higher efficiency of the turbine and the efficiency (enhanced) change was contributed because of the vortex formation in different locations in the flow passage or near the blade surface.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The Performance of a Cross-flow Turbine as a Function of Flowrates and Guide Vane Angles
    Adeyanju A.A.
    Manohar K.
    HighTech and Innovation Journal, 2022, 3 (01): : 56 - 64
  • [42] Impact of guide vane opening angle on the flow stability in a pump-turbine in pump mode
    Zhu, Di
    Xiao, Ruofu
    Tao, Ran
    Liu, Weichao
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (13) : 2484 - 2492
  • [43] The film cooling performance of spiral-channel holes on turbine guide vane
    Jia, Yuhao
    Liu, Yongbao
    Meng, Zewei
    He, Xing
    Liu, Yang
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
  • [44] In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane
    Martinez, Jayson J.
    Deng, Zhiqun Daniel
    Mueller, Robert
    Titzler, Scott
    APPLIED ENERGY, 2020, 276
  • [45] Experimental study of a novel hinged vane rotary turbine - part I: The effect of different vane thickness and vane weight on turbine performance
    Okur, Melih
    Arabaci, Emre
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 70 - 76
  • [46] Cooling system optimisation of turbine guide vane
    Nowak, Grzegorz
    Wroblewski, Wlodzimierz
    APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 567 - 572
  • [47] Effect of Hot Streak on Aerothermal Performance of High Pressure Turbine Guide Vane under Different Swirl Intensities
    Zhang, Shenghui
    Ding, Shuiting
    Liu, Peng
    Qiu, Tian
    AEROSPACE, 2022, 9 (10)
  • [48] A straight-bladed vertical axis turbine for wave energy conversion: Effect of guide vane position on the performance
    Sakaguchi, Masaki
    Hayamizu, Yasutaka
    Gonda, Takeshi
    Morita, Shinichi
    Ohtsuka, Shigeru
    Takao, Manabu
    Kinoue, Yoichi
    Setoguchi, Toshiaki
    29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [49] EFFECT OF INTERFACE CONDITION ON THE HYDRAULIC PERFORMANCE OF A PUMP - TURBINE AT VARIOUS GUIDE VANE OPENING CONDITIONS IN PUMPING MODE
    Suh, Jun-Won
    Kim, Seung-Jun
    Choi, Young-Seok
    Kim, Jin-Hyuk
    Joo, Won-Gu
    Park, Jungwan
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2019, VOL 3B, 2019,
  • [50] THE EFFECT OF PURGE AIR ON THE AERODYNAMIC PERFORMANCE OF A STATE-OF-THE-ART TURBINE-REAR-FRAME GUIDE VANE
    Schien, Malte
    Wakelam, Chris
    Graiff, Mattia
    Goettlich, Emil
    Marn, Andreas
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 13C, 2023,