A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images

被引:58
作者
Eilertsen, Karsten [1 ]
Vestad, Line Nilsen Tor Arne [1 ]
Geier, Oliver [1 ]
Skretting, Arne [1 ]
机构
[1] Univ Hosp, Rikshosp, Dept Med Phys, Div Canc Med & Radiotherapy, N-0310 Oslo, Norway
关键词
LOCALIZED PROSTATE-CANCER; BRAIN-TUMORS; FEASIBILITY;
D O I
10.1080/02841860802256426
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. The advantage of MRI-based radiotherapy planning is the superior soft tissue differentiation. However, for accurate patient dose calculations, a conversion of the MR images into Hounsfield CT maps is necessary. The aim of the present study was to investigate the dose accuracy that can be achieved with segmented MR-images derived from the planning CT images by assigning fixed densities to different classes of tissues. Methods. Treatment plans for ten prostate cancer patients were selected. A collapsed cone algorithm was used to calculate patient dose distributions. The dose calculations were based on four different image sets: (1) the original CT-series (DD(DP)), (2) a simulated MR series with all tissue set to a homogenous water equivalent material of density 1.02 g/cm(3) (DD(W)), (3) a simulated MR series with soft tissue set to a water equivalent material with density 1.02 g/cm3 and the bone set to a density of 1.3 g/cm3 (DD(W+B1.3)), and (4) a simulated MR series identical to (3) but with a bone density equal to 2.1 g/cm3 (DD(W+B2.1)). The dose distributions were compared by analysing dose difference histograms as well as through a visual display of spatial dose deviations. Results. The population based minimum, mean and maximum dose difference between the DD(DP) and DD(W) in the target volume was -2.8, -1.0 and 0.6%, respectively. Corresponding differences between DD(DP) and DD(W+B1.3) were -1.6, 0.2 and 1.5%, respectively, and between DD(DP) and DD(W+B2.1) -4.3, 4.2 and 9.7%, respectively. For the rectum, the differences between CT(DP) and the other image sets were in the range of -19.5 to 8.8%. For the bladder, the differences were in the range of -9.6 to 7.0%. Conclusions. A systematic study using segmented MR images was undertaken. To achieve an acceptable accuracy in the CTV dose, the MR images should be segmented into bone and water equivalent tissue. Still, significant dose deviation for the organs at risk may be present. As tissue segmentation in real MR images is introduced, segmentation errors and errors that stem from geometrical non-linearities may further reduce the accuracy.
引用
收藏
页码:1294 / 1302
页数:9
相关论文
共 14 条
  • [1] Radiotherapy treatment planning of brain tumours using MRI alone
    Beavis, AW
    Gibbs, P
    Dealey, RA
    Whitton, VJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (845) : 544 - 548
  • [2] Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    Chen, L
    Price, RA
    Nguyen, TB
    Wang, L
    Li, JS
    Qin, L
    Ding, M
    Palacio, E
    Ma, CM
    Pollack, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22) : 5157 - 5170
  • [3] Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy:: Creation of digitally reconstructed radiographs
    Chen, Lili
    Nguyen, Thai-Binh
    Jones, Elan
    Chen, Zuoqun
    Luo, Wei
    Wang, Lu
    Price, Robert A., Jr.
    Pollack, Alan
    Ma, C.-M. Charlie
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 903 - 911
  • [4] MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
    Chen, LL
    Price, RA
    Wang, L
    Li, JS
    Qin, LH
    McNeeley, S
    Ma, CMC
    Freedman, GM
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 636 - 647
  • [5] The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer
    Debois, M
    Oyen, R
    Maes, F
    Verswijvel, G
    Gatti, G
    Bosmans, H
    Feron, M
    Bellon, E
    Kutcher, G
    Van Poppel, H
    Vanuytsel, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04): : 857 - 865
  • [6] Aspects of MR image distortions in radiotherapy treatment planning
    Fransson, A
    Andreo, P
    Pötter, R
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2001, 177 (02) : 59 - 73
  • [7] Comparison of MRI with CT for the radiotherapy planning of prostate cancer: a feasibility study
    Khoo, VS
    Padhani, AR
    Tanner, SF
    Finnigan, DJ
    Leach, MO
    Dearnaley, DP
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (858) : 590 - 597
  • [8] Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning
    Khoo, VS
    Dearnaley, DP
    Finnigan, DJ
    Padhani, A
    Tanner, SF
    Leach, MO
    [J]. RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) : 1 - 15
  • [9] Dosimetric and geometric evaluation of an open low-field magnetic resonance simulator for radiotherapy treatment planning of brain tumours
    Kristensen, Brian Holch
    Laursen, Finn Jorgen
    Logager, Vibeke
    Geertsen, Pout Flemming
    Krarup-Hansen, Anders
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 87 (01) : 100 - 109
  • [10] Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone
    Lee, YK
    Bollet, M
    Charles-Edwards, G
    Flower, MA
    Leach, MO
    McNair, H
    Moore, E
    Rowbottom, C
    Webb, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) : 203 - 216