A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

被引:134
作者
Michell, M. J. [1 ]
Iqbal, A.
Wasan, R. K.
Evans, D. R.
Peacock, C.
Lawinski, C. P. [2 ]
Douiri, A. [3 ,6 ]
Wilson, R. [4 ]
Whelehan, P. [5 ]
机构
[1] Kings Coll Hosp London, Breast Radiol Dept, London SE5 9RS, England
[2] Kings Coll Hosp London, KCARE, London SE5 9RS, England
[3] Kings Coll London, Dept Primary Care & Publ Hlth Sci, London WC2R 2LS, England
[4] Royal Marsden NHS Fdn Trust, Dept Clin Radiol, Surrey, England
[5] Univ Dundee, Ninewells Hosp & Med Sch, Med Res Inst, Dundee DD1 9SY, Scotland
[6] Guys & St Thomas NHS Fdn Trust, Natl Inst Hlth Res, Comprehens Biomed Res Ctr, London, England
关键词
POPULATION;
D O I
10.1016/j.crad.2012.03.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. MATERIALS AND METHODS: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. RESULTS: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286(37.68%) as benign, and 269(35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBTcombined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. CONCLUSION: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:976 / 981
页数:6
相关论文
共 19 条
[1]   Breast tomosynthesis and digital mammography: a comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings [J].
Andersson, Ingvar ;
Ikeda, Debra M. ;
Zackrisson, Sophia ;
Ruschin, Mark ;
Svahn, Tony ;
Timberg, Pontus ;
Tingberg, Anders .
EUROPEAN RADIOLOGY, 2008, 18 (12) :2817-2825
[2]  
[Anonymous], 2005, NHSBSP PUBL
[3]  
[Anonymous], 2010, DIG BREAST TOM
[4]  
[Anonymous], 1994, IPEM REP
[5]  
[Anonymous], STAT STAT SOFTW
[6]   Digital breast tomosynthesis versus digital mammography: a clinical performance study [J].
Gennaro, Gisella ;
Toledano, Alicia ;
di Maggio, Cosimo ;
Baldan, Enrica ;
Bezzon, Elisabetta ;
La Grassa, Manuela ;
Pescarini, Luigi ;
Polico, Ilaria ;
Proietti, Alessandro ;
Toffoli, Aida ;
Muzzio, Pier Carlo .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1545-1553
[7]   Digital breast tomosynthesis: A pilot observer study [J].
Good, Walter F. ;
Abrams, Gordon S. ;
Catullo, Victor J. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :865-869
[8]   Digital Breast Tomosynthesis: Observer Performance Study [J].
Gur, David ;
Abrams, Gordon S. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Hakim, Christiane M. ;
Perrin, Ronald L. ;
Rathfon, Grace Y. ;
Sumkin, Jules H. ;
Zuley, Margarita L. ;
Bandos, Andriy I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) :586-591
[9]   Digital Breast Tomosynthesis in the Diagnostic Environment: A Subjective Side-by-Side Review [J].
Hakim, Christiane M. ;
Chough, Denise M. ;
Ganott, Marie A. ;
Sumkin, Jules H. ;
Zuley, Margarita L. ;
Gur, David .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) :W172-W176
[10]   Comparison of Digital Mammography and Screen-Film Mammography in Breast Cancer Screening: A Review in the Irish Breast Screening Program [J].
Hambly, Niamh M. ;
McNicholas, Michelle M. ;
Phelan, Niall ;
Hargaden, Gormlaith C. ;
O'Doherty, Ann ;
Flanagan, Fidelma L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1010-1018