Experimental investigation of an ejector-enhanced auto-cascade refrigeration system

被引:63
作者
Bai, Tao [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Experimental investigation; Ejector; Zeotropic refrigerant; Auto-cascade refrigeration; Exergy efficiency; CO2; HEAT-PUMP; EXERGY ANALYSIS; PERFORMANCE; CYCLE; MIXTURE; ENERGY;
D O I
10.1016/j.applthermaleng.2017.10.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents the experimental investigation of an ejector-enhanced auto-cascade refrigeration cycle (EARC) with zeotropic refrigerant R134a/R23. Performance comparisons among the EARC and two conventional cycles were conducted at selected operating conditions. The effects of ambient temperature, charged mass fraction ratio of the mixture, throttle valve opening, and heat load on the performance characteristics of the EARC were investigated. The results indicated that the EARC had more advantages in terms of lower refrigeration temperature and higher energy utilization efficiency over the conventional cycles, and the coefficient of performance (COP) and exergy efficiency improvements of the EARC reached up to 9.6% and 25.1%, respectively. The throttle valve opening was optimal with respect to the maximum system exergy efficiency determination. The refrigerant R134a/R23 with the optimal mass fraction ratio of 0.70/0.30 was proposed. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:792 / 801
页数:10
相关论文
共 27 条
[11]  
Kleemenko A.P., 1959, P 10 INT C REFRIGERA, V1, P34
[12]  
Kline S.J., 1952, ASME Mechanical Engineering, V75, P3
[13]   Compression-injection hybrid refrigeration cycles in household refrigerators [J].
Liu, Yicai ;
Xin, Tianlong ;
Cao, Lihong ;
Wan, Chao ;
Zhang, Mingyan .
APPLIED THERMAL ENGINEERING, 2010, 30 (16) :2442-2447
[14]   A method for estimating the composition of the mixture to be charged to get the desired composition in circulation in a single stage JT refrigerator operating with mixtures [J].
Narasimhan, N. Lakshmi ;
Venkatarathnam, G. .
CRYOGENICS, 2010, 50 (02) :93-101
[15]   Occurrence of Dry-Out Phenomenon in an Auto Refrigerant Cascade Refrigerator Operating With Zeotropic Mixtures [J].
Nayak, H. Gurudath ;
Venkatarathnam, G. .
JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2017, 9 (03)
[16]  
Podbielniak W.J., 1936, Art of refrigeration, Patent No. [2,041,725, 2041725]
[17]   Optimization of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications [J].
Sarkar, J ;
Bhattacharyya, S ;
Gopal, MR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :830-838
[18]   Exergy and energy analysis of three stage auto refrigerating cascade system using Zeotropic mixture for sustainable development [J].
Sivakumar, M. ;
Somasundaram, P. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 84 :589-596
[19]   Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode [J].
Sreenivas, Bura ;
Nayak, H. Gurudath ;
Venkatarathnam, G. .
CRYOGENICS, 2017, 81 :42-46
[20]   Thermodynamic performance of an auto-cascade ejector refrigeration cycle with mixed refrigerant R32+R236fa [J].
Tan, Yingying ;
Wang, Lin ;
Liang, Kunfeng .
APPLIED THERMAL ENGINEERING, 2015, 84 :268-275