A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol

被引:32
作者
Li, Zhen [1 ]
Yue, Yuhua [1 ]
Hao, Yanjun [1 ]
Feng, Shun [1 ]
Zhou, Xianli [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Life Sci & Engn, Chengdu 610031, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemically modified electrode; Cerium phosphate; Dihydroxybenzene isomers; Simultaneous detection; Water sample; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; GRAPHENE; COMPOSITE; OXIDATION; SENSOR; FILMS;
D O I
10.1007/s00604-018-2748-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nafion film containing cerium phosphate nanotubes was pasted onto a glassy carbon electrode (GCE) to obtain a sensor for hydroquinone (HQ). The morphologies and components of the coating were characterized by transmission electron microscopy, scanning electron microscopy and energy-dispersive spectroscopy. Cyclic voltammetry and differential pulse voltammetry (DPV) showed the specific surface of the electrode to be significantly increased and the electron transfer rate to be accelerated. The modified GCE was applied to the determination of hydroquinone (HQ) via DPV. The oxidation current increases linearly in the 0.23 mu M to 16 mM HQ concentration range which is as wide as five orders of magnitude. The limit of detection is 0.12 mu M (based on a signal-to-noise ratio of 3), and the sensitivity is 1.41 mu A.mu M-1 cm(-2). The method was further applied to the simultaneous determination of HQ, catechol and resorcinol. The potentials for the three species are well separated (20, 134, and 572 mV vs SCE). Average recoveries from (spiked) real water samples are between 95.2 and 107.0%, with relative standard deviations of 0.9 similar to 2.7% (for n = 3) at three spiking levels. The method was validated by independent assays using HPLC.
引用
收藏
页数:9
相关论文
共 40 条
[1]   Voltammetric determination of dihydroxybenzene isomers using a disposable pencil graphite electrode modified with cobalt-phthalocyanine [J].
Buleandra, Mihaela ;
Rabinca, Andreea Alexandra ;
Badea, Irinel Adriana ;
Balan, Adriana ;
Stamatin, Ioan ;
Mihailciuc, Constantin ;
Ciucu, Anton Alexandru .
MICROCHIMICA ACTA, 2017, 184 (05) :1481-1488
[2]   Screen-printed Prussian Blue modified electrode for simultaneous detection of hydroquinone and catechol [J].
Buleandra, Mihaela ;
Rabinca, Andreea Alexandra ;
Mihailciuc, Constantin ;
Balan, Adriana ;
Nichita, Cornelia ;
Stamatin, Ioan ;
Ciucu, Anton Alexandru .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 :824-832
[3]   Selective electrochemical detection of hydroquinone and catechol at a one-step synthesised pine needle-like nano-CePO4 modified carbon paste electrode [J].
Dang, Yuan ;
Zhai, Yanyan ;
Yang, Lehui ;
Peng, Zhenli ;
Cheng, Nan ;
Zhou, Yuanzhen .
RSC ADVANCES, 2016, 6 (87) :83994-84002
[4]   Biomimetic sensor based on a novel copper complex for the determination of hydroquinone in cosmetics [J].
de Oliveira, Ines Rosane W. Z. ;
Osoria, Renata El-Hage M. de Barros ;
Neves, Ademir ;
Vieira, Iolanda Cruz .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :89-94
[5]   Carbon nanotubes: A review of their properties in relation to pulmonary toxicology and workplace safety [J].
Donaldson, Ken ;
Aitken, Robert ;
Tran, Lang ;
Stone, Vicki ;
Duffin, Rodger ;
Forrest, Gavin ;
Alexander, Andrew .
TOXICOLOGICAL SCIENCES, 2006, 92 (01) :5-22
[6]   Amperometric sensing of catechol using a glassy carbon electrode modified with ferrocene covalently immobilized on graphene oxide [J].
Elancheziyan, Mari ;
Manoj, Devaraj ;
Saravanakumar, Duraisamy ;
Thenmozhi, Kathavarayan ;
Senthilkumar, Sellappan .
MICROCHIMICA ACTA, 2017, 184 (08) :2925-2932
[7]   Progress towards monodisperse single-walled carbon nanotubes [J].
Hersam, Mark C. .
NATURE NANOTECHNOLOGY, 2008, 3 (07) :387-394
[8]   Amperometric sensing of hydroquinone using a glassy carbon electrode modified with a composite consisting of graphene and molybdenum disulfide [J].
Huang, Huayu ;
Zhang, Jiangyi ;
Cheng, Meimei ;
Liu, Kunping ;
Wang, Xingyu .
MICROCHIMICA ACTA, 2017, 184 (12) :4803-4808
[9]   Simultaneous electrochemical determination of dihydroxybenzene isomers using electrospun nitrogen-doped carbon nanofiber film electrode [J].
Huang, Jianshe ;
Zhang, Xueping ;
Zhou, Limin ;
You, Tianyan .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 :568-576
[10]   Graphene quantum dots modified glassy carbon electrode via electrostatic self-assembly strategy and its application [J].
Jian, Xuan ;
Liu, Xian ;
Yang, Hui-min ;
Guo, Min-min ;
Song, Xiu-li ;
Dai, Hong-yan ;
Liang, Zhen-hai .
ELECTROCHIMICA ACTA, 2016, 190 :455-462