Research the Method of evaluation microwave power standard correction factor Uncertainty based on the theory of electromagnetic field

被引:0
作者
Sun, Weijie [1 ]
Cui, Xiaohai [1 ]
Li, Yong [2 ]
机构
[1] 18 Jiaodadonglu St, Beijing, Peoples R China
[2] 18 Beisanhuandonglu St, Beijing, Peoples R China
来源
MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3 | 2013年 / 333-335卷
关键词
Microwave Power Standard; correction factor; Uncertainty; electromagnetic field;
D O I
10.4028/www.scientific.net/AMM.333-335.284
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Microwave power standard adopts calorimetry techniques to calibrate the effective efficiency of the thermistor mount. Correction factor is the key of calibration thermistor mount. The microwave power standard mainly adopted short-circuited mode to determine the correction factor so far, but it must consider the effects of microwave power absorbed by short plate to thermopile, so the method that how to get the power dissipated in the short plate is the key to calculating correction factor and its uncertainty. This paper presents a new method based on electromagnetic field theory to consider the short-circuit dissipation power. A detailed analysis of its superiority over the traditional method is shown. It reduces the uncertainty of the correction factor reasonably, in other words, reduces the uncertainty of the microwave power standard.
引用
收藏
页码:284 / +
页数:2
相关论文
共 4 条
[1]  
Allen J. W., 1999, NIST Technical Note 1511
[2]  
Beatty R.W., 1973, NBS US MONOGRAPH, V137
[3]  
Crowley T.P., 2008, CPEM 2008 C JUN
[4]  
Run Runqing, 2008, FDN MICROWAVE TECHNO