Label-free sensor for automatic identification of erythrocytes using digital in-line holographic microscopy and machine learning

被引:32
作者
Go, Taesik [1 ]
Byeon, Hyeokjun [1 ]
Lee, Sang Joon [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Mech Engn, Pohang 790784, South Korea
基金
新加坡国家研究基金会;
关键词
Cell type classification; Erythrocyte; Digital in-line holographic microscopy; Machine learning; RED-BLOOD-CELL; MORPHOLOGY-BASED CLASSIFICATION; STORAGE; VISCOSITY; TRANSFUSION; HEMOGLOBIN; MECHANICS;
D O I
10.1016/j.bios.2017.12.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Cell types of erythrocytes should be identified because they are closely related to their functionality and viability. Conventional methods for classifying erythrocytes are time consuming and labor intensive. Therefore, an automatic and accurate erythrocyte classification system is indispensable in healthcare and biomedical fields. In this study, we proposed a new label-free sensor for automatic identification of erythrocyte cell types using a digital in-line holographic microscopy (DIHM) combined with machine learning algorithms. A total of 12 features, including information on intensity distributions, morphological descriptors, and optical focusing characteristics, is quantitatively obtained from numerically reconstructed holographic images. All individual features for discocytes, echinocytes, and spherocytes are statistically different. To improve the performance of cell type identification, we adopted several machine learning algorithms, such as decision tree model, support vector machine, linear discriminant classification, and k-nearest neighbor classification. With the aid of these machine learning algorithms, the extracted features are effectively utilized to distinguish erythrocytes. Among the four tested algorithms, the decision tree model exhibits the best identification performance for the training sets (n = 440, 98.18%) and test sets (n = 190, 97.37%). This proposed methodology, which smartly combined DIHM and machine learning, would be helpful for sensing abnormal erythrocytes and computer-aided diagnosis of hematological diseases in clinic.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 46 条
  • [1] [Anonymous], SCI REP
  • [2] Sickle Cell Biomechanics
    Barabino, Gilda A.
    Platt, Manu O.
    Kaul, Dhananjay K.
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 12, 2010, 12 : 345 - 367
  • [3] Baskurt OK, 2003, SEMIN THROMB HEMOST, V29, P435
  • [4] Evolution of adverse changes in stored RBCs
    Bennett-Guerrero, Elliott
    Veldman, Tim H.
    Doctor, Allan
    Telen, Marilyn J.
    Ortel, Thomas L.
    Reid, T. Scott
    Mulherin, Melissa A.
    Zhu, Hongmei
    Buck, Raymond D.
    Califf, Robert M.
    McMahon, Timothy J.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (43) : 17063 - 17068
  • [5] Influence of storage on red blood cell rheological properties
    Berezina, TL
    Zaets, SB
    Morgan, C
    Spillert, CR
    Kamiyama, M
    Spolarics, Z
    Deitch, EA
    Machiedo, GW
    [J]. JOURNAL OF SURGICAL RESEARCH, 2002, 102 (01) : 6 - 12
  • [6] Red blood cell storage and cell morphology
    Blasi, B.
    D'Alessandro, A.
    Ramundo, N.
    Zolla, L.
    [J]. TRANSFUSION MEDICINE, 2012, 22 (02) : 90 - 96
  • [7] Precise measurement of orientations of transparent ellipsoidal particles through digital holographic microscopy
    Byeon, Hyeokjun
    Go, Taesik
    Lee, Sang Joon
    [J]. OPTICS EXPRESS, 2016, 24 (01): : 598 - 610
  • [8] Advances in digital holographic micro-PTV for analyzing microscale flows
    Choi, Yong-Seok
    Seo, Kyung-Won
    Sohn, Myong-Hwan
    Lee, Sang-Joon
    [J]. OPTICS AND LASERS IN ENGINEERING, 2012, 50 (01) : 39 - 45
  • [9] High-accuracy three-dimensional position measurement of tens of micrometers size transparent microspheres using digital in-line holographic microscopy
    Choi, Yong-Seok
    Lee, Sang-Joon
    [J]. OPTICS LETTERS, 2011, 36 (21) : 4167 - 4169
  • [10] Three-dimensional volumetric measurement of red blood cell motion using digital holographic microscopy
    Choi, Yong-Seok
    Lee, Sang-Joon
    [J]. APPLIED OPTICS, 2009, 48 (16) : 2983 - 2990