A comprehensive diagnosis system for early signs and different diabetic retinopathy grades using fundus retinal images based on pathological changes detection

被引:20
作者
AbdelMaksoud, Eman [1 ]
Barakat, Sherif [1 ]
Elmogy, Mohammed [2 ]
机构
[1] Mansoura Univ, Fac Comp & Informat, Informat Syst Dept, PO 35516, Mansoura, Egypt
[2] Mansoura Univ, Fac Comp & Informat, Informat Technol Dept, PO 35516, Mansoura, Egypt
关键词
Multi-label computer-aided diagnostic (CAD); Multi-label classification (MLC); Diabetic retinopathy (DR); Blood vessels (BV); Exudates (EX); Microaneurysms (MA); Hemorrhages (HM); VESSEL SEGMENTATION;
D O I
10.1016/j.compbiomed.2020.104039
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Multi-label classification (MLC) is deemed as an effective and dynamic research topic in the medical image analysis field. For ophthalmologists, MLC benefits can be utilized to detect early diabetic retinopathy (DR) signs, as well as its different grades. This paper proposes a comprehensive computer-aided diagnostic (CAD) system that exploits the MLC of DR grades using colored fundus photography. The proposed system detects and analyzes various retina pathological changes accompanying DR development. We extracted some significant features to differentiate healthy from DR cases as well as differentiate various DR grades. First, we preprocessed the retinal images to eliminate noise and enhance the image quality by using histogram equalization for brightness preservation based on dynamic stretching technique. Second, the images were segmented to extract four pathology variations, which are blood vessels, exudates, microaneurysms, and hemorrhages. Next, six various features were extracted using a gray level co-occurrence matrix, the four extracting areas, and blood-vessel bifurcation points. Finally, the features were supplied to a support vector machine (SVM) classifier to distinguish normal and different DR grades. To train and test the proposed system, we utilized four benchmark datasets (two of them are multi-label datasets) using six performance metrics. The proposed system achieved an average accuracy of 89.2%, sensitivity of 85.1%, specificity of 85.2%, positive predictive value of 92.8%, area under the curve of 85.2%, and Disc similarity coefficient (DSC) of 88.7%. The experiments show promising results as compared with other systems.
引用
收藏
页数:23
相关论文
共 46 条
[1]   Brain tumor segmentation based on a hybrid clustering technique [J].
Abdel-Maksoud, Eman ;
Elmogy, Mohammed ;
Al-Awadi, Rashid .
EGYPTIAN INFORMATICS JOURNAL, 2015, 16 (01) :71-81
[2]  
AbdelMaksoud E., 2019, 14 INT C COMP ENG SY, P386
[3]   Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection [J].
Agurto, Carla ;
Murray, Victor ;
Barriga, Eduardo ;
Murillo, Sergio ;
Pattichis, Marios ;
Davis, Herbert ;
Russell, Stephen ;
Abramoff, Michael ;
Soliz, Peter .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) :502-512
[4]  
[Anonymous], 2019, IEEE ACCESS
[5]  
[Anonymous], 2013, Journal of Computer Science, DOI DOI 10.3844/JCSSP.2013.1389.1395
[6]  
[Anonymous], 2015, International Journal of Image Processing (IJIP)
[7]   Trainable COSFIRE filters for vessel delineation with application to retinal images [J].
Azzopardi, George ;
Strisciuglio, Nicola ;
Vento, Mario ;
Petkov, Nicolai .
MEDICAL IMAGE ANALYSIS, 2015, 19 (01) :46-57
[8]  
Coye T., 2017, NOVEL RETINAL BLOOD
[9]   FEEDBACK ON A PUBLICLY DISTRIBUTED IMAGE DATABASE: THE MESSIDOR DATABASE [J].
Decenciere, Etienne ;
Zhang, Xiwei ;
Cazuguel, Guy ;
Lay, Bruno ;
Cochener, Beatrice ;
Trone, Caroline ;
Gain, Philippe ;
Ordonez-Varela, John-Richard ;
Massin, Pascale ;
Erginay, Ali ;
Charton, Beatrice ;
Klein, Jean-Claude .
IMAGE ANALYSIS & STEREOLOGY, 2014, 33 (03) :231-234
[10]  
Evaluation W D.M., 2011, J MACH LEARN TECHNOL, V2, P37, DOI DOI 10.9735/2229-3981