Autonomic Nervous System Responses Can Reveal Visual Fatigue Induced by 3D Displays

被引:31
作者
Kim, Chi Jung [1 ]
Park, Sangin [1 ]
Won, Myeung Ju [1 ]
Whang, Mincheol [2 ]
Lee, Eui Chul [3 ]
机构
[1] Sangmyung Univ, Grad Sch, Dept Emot Engn, Seoul 110743, South Korea
[2] Sangmyung Univ, Dept Digital Media, Seoul 110743, South Korea
[3] Sangmyung Univ, Dept Comp Sci, Seoul 110743, South Korea
基金
新加坡国家研究基金会;
关键词
visual fatigue; autonomic nervous system; heart rate; galvanic skin response; skin temperature;
D O I
10.3390/s131013054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Previous research has indicated that viewing 3D displays may induce greater visual fatigue than viewing 2D displays. Whether viewing 3D displays can evoke measureable emotional responses, however, is uncertain. In the present study, we examined autonomic nervous system responses in subjects viewing 2D or 3D displays. Autonomic responses were quantified in each subject by heart rate, galvanic skin response, and skin temperature. Viewers of both 2D and 3D displays showed strong positive correlations with heart rate, which indicated little differences between groups. In contrast, galvanic skin response and skin temperature showed weak positive correlations with average difference between viewing 2D and 3D. We suggest that galvanic skin response and skin temperature can be used to measure and compare autonomic nervous responses in subjects viewing 2D and 3D displays.
引用
收藏
页码:13054 / 13062
页数:9
相关论文
共 19 条
  • [1] Mental fatigue, work and sleep
    Åkerstedt, T
    Knutsson, A
    Westerholm, P
    Theorell, T
    Alfredsson, L
    Kecklund, G
    [J]. JOURNAL OF PSYCHOSOMATIC RESEARCH, 2004, 57 (05) : 427 - 433
  • [2] CARROLL EI, 1977, HUMAN EMOTIONS
  • [3] Emoto M, 2005, J DISP TECHNOL, V1, P328, DOI 10.1109/JDT.2005.858938
  • [4] Multiscale Entropy Approach to Physiological Fatigue during Long-Term Web Browsing
    Hung, C. H.
    Jiang, Bernard C.
    [J]. HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING, 2009, 19 (05): : 478 - 493
  • [5] Kim Y.J., 2011, Int. Conference on Human-Comp. Interaction, V2, P289
  • [6] Lambooij M.T.M., 2007, P STER DISPL VIRT RE
  • [7] Lee C., 2006, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, P5523
  • [8] The Comparative Measurements of Eyestrain Caused by 2D and 3D Displays
    Lee, Eui Chul
    Heo, Hwan
    Park, Kang Ryoung
    [J]. IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2010, 56 (03) : 1677 - 1683
  • [9] Li Hyung-Chul O., 2008, 2008 3DTV-Conference: The True Vision - Capture, Transmission and Display of 3D Video, P213, DOI 10.1109/3DTV.2008.4547846
  • [10] Li Hyung-Chul, 2010, [JOURNAL OF BROADCAST ENGINEERING, 방송공학회 논문지], V15, P607