On Non-Invasive Glucose Measurements

被引:1
|
作者
Aroutiounian, V. M. [1 ]
机构
[1] Yerevan State Univ, Yerevan, Armenia
关键词
glucose; diabetes; noninvasive method; bio-impedance; skin; near IR range; Raman scattering; polarization vector; MULTISENSOR SYSTEM; BLOOD-GLUCOSE; SENSORS; FREQUENCY; SIMULATION; LIGHT;
D O I
10.1134/S1068337222040041
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Conventional glucose testing methods require the analysis of a droplet of blood from the patient's finger, which is painful and inconvenient. Such a one-time method carries an infectious risk and is not suitable for the long-term, daily continuous glucose monitoring often required today. Continuous glucose monitoring can provide timely information about the success of therapy during treatment and make appropriate adjustments. Currently, there is no single method of continuous monitoring. Currently, there is no single method of continuous monitoring. Glucose concentrations, although different kinds of non-invasive sensors have been developed for such monitoring on different physical principles. Such devices can provide painless, risk-free, inexpensive and frequent testing. This article discusses recent advances in non-invasive glucose control techniques.
引用
收藏
页码:405 / 416
页数:12
相关论文
共 50 条
  • [31] Design and Implementation of a Non-Invasive RF Device to Measure Glucose in Blood
    Gelosi, Ivan Exequiel
    Ribas, Ramiro Avalos
    Uriz, Alejandro Jose
    Moreira, Jorge Castifieira
    Fuentes, Nora
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (05) : 813 - 822
  • [32] In vivo wearable non-invasive glucose monitoring based on dielectric spectroscopy
    Liu, Yuhang
    Xia, Meng
    Nie, Zedong
    Li, Jingzhen
    Zeng, Yicheng
    Wang, Lei
    PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 1388 - 1391
  • [33] Mice Glucose Level Monitoring by a Non-Invasive Microwave Imaging Technique
    Baghdasaryan, Zhirayr
    Babajanyan, Arsen
    Jeong, Sua
    Lee, Jung-Ha
    Friedman, Barry
    Lee, Kiejin
    IEEE ACCESS, 2024, 12 : 139711 - 139723
  • [34] A Review of Minimally and Non-invasive Glucose Monitoring Techniques, Devices and Sensors
    Nooshnab, Mohammad
    Naghib, Seyed Morteza
    Rahmanifard, Rouhollah
    Khakpour, Elnaz
    CURRENT ANALYTICAL CHEMISTRY, 2024, 20 (04) : 217 - 241
  • [35] A Novel Fingertip Model for Microwave Non-invasive Blood Glucose Simulations
    Ribas, Ramiro Avalos
    Moreira, Jorge Castineira
    Uriz, Alejandro Jose
    IEEE SENSORS LETTERS, 2024, 8 (04) : 1 - 4
  • [36] A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring
    Alsunaidi, Bushra
    Althobaiti, Murad
    Tamal, Mahbubunnabi
    Albaker, Waleed
    Al-Naib, Ibraheem
    SENSORS, 2021, 21 (20)
  • [37] Non-Invasive Assessment of Blood Glucose Changes with Near Infrared Sensor
    Mamilov, Serhii
    Velyhotskyi, Dmytro
    Yesman, Serhii
    Mysiura, Anatolii
    Bekh, Ihor
    Gisbrecht, Alexander
    2020 IEEE 40TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2020, : 536 - 540
  • [38] Non-Invasive Blood Glucose Monitoring Device Using Photoacoustic Spectroscopy
    Jahana, Takahito
    Higa, Hiroki
    2020 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATICS AND BIOMEDICAL SCIENCES (ICIIBMS 2020), 2020, : 85 - 88
  • [39] The effect of temperature on permittivity measurements of aqueous solutions of glucose for the development of non-invasive glucose sensors based on electromagnetic waves
    Jayanthi, Renu Karthick Rajaguru
    Virdee, Bal S.
    Lubangakene, Innocent
    Ganguly, Priyanka
    Mariyanayagam, Dion
    RESULTS IN ENGINEERING, 2023, 20
  • [40] Non-invasive blood glucose monitoring is an elusive goose
    Devi Dayal
    International Journal of Diabetes in Developing Countries, 2016, 36 : 399 - 400