Comparison of two inspiratory: expiratory ratios during high frequency oscillation

被引:6
作者
Dimitriou, G
Greenough, A
Kavvadia, V
Milner, AD
机构
[1] Univ London Kings Coll Hosp, Childrens Nationwide Reg Neonatal Intens Care Ctr, London SE5 9RS, England
[2] United Med & Dent Sch Guys & St Thomas Hosp, St Thomas Hosp, Dept Paediat, London SE1 7EH, England
关键词
high frequency oscillation; respiratory distress syndrome;
D O I
10.1007/s004310051208
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The aim of this study was to compare gas exchange and volume delivery during high frequency oscillation at two frequently used inspiratory:expiratory (I:E) ratios: 1:2 and 1:1, other oscillatory settings being kept constant. A group of 13 infants with respiratory distress syndrome, median gestational age 28 weeks (range 23-36) and postnatal age 1 day (range 1-8) were studied. At the I:E ratio of 1:1 compared to 1:2 the median paCO(2) was lower, P < 0.05 (30 mmHg, range 22-47 vs 34 mmHg, range 27-46) and the volume delivered higher, P < 0.01 (2.6 ml/kg, range 1.2-5.6 vs 2.0 ml/kg, range 1.0-3.9). There was no significant difference in oxygenation levels at the two I:E ratios. In a related in vitro study. changing the I:E ratio from 1.2 to 1:1 increased the mean airway pressure by a median of 8.6% (range 2.9-28.1%). Conclusion Routinely maintained longer expiratory than inspiratory times during high frequency oscillation should be discouraged.
引用
收藏
页码:796 / 799
页数:4
相关论文
共 17 条
  • [1] Determination of gas-trapping during high frequency oscillatory ventilation
    Alexander, J
    Milner, AD
    [J]. ACTA PAEDIATRICA, 1997, 86 (03) : 268 - 273
  • [2] GAS TRAPPING WITH HIGH-FREQUENCY VENTILATION - JET VERSUS OSCILLATORY VENTILATION
    BANCALARI, A
    GERHARDT, T
    BANCALARI, E
    SUGUIHARA, C
    HEHRE, D
    REIFENBERG, L
    GOLDBERG, RN
    [J]. JOURNAL OF PEDIATRICS, 1987, 110 (04) : 617 - 622
  • [3] EFFECT OF MEAN AIRWAY PRESSURE ON GAS-EXCHANGE DURING HIGH-FREQUENCY OSCILLATORY VENTILATION
    BOYNTON, BR
    VILLANUEVA, D
    HAMMOND, MD
    VREELAND, PN
    BUCKLEY, B
    FRANTZ, ID
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) : 701 - 707
  • [4] BRYAN AC, 1986, AM REV RESPIR DIS, V133, P928
  • [5] THE EFFECT OF FREQUENCY ON CARBON-DIOXIDE LEVELS DURING HIGH-FREQUENCY OSCILLATION
    CHAN, V
    GREENOUGH, A
    [J]. JOURNAL OF PERINATAL MEDICINE, 1994, 22 (02) : 103 - 106
  • [6] HIGH-FREQUENCY OSCILLATION FOR PRETERM INFANTS WITH SEVERE RESPIRATORY-FAILURE
    CHAN, V
    GREENOUGH, A
    GAMSU, HR
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1994, 70 (01): : F44 - F46
  • [7] THE EFFECT OF FREQUENCY AND MEAN AIRWAY PRESSURE ON VOLUME DELIVERY DURING HIGH-FREQUENCY OSCILLATION
    CHAN, V
    GREENOUGH, A
    MILNER, AD
    [J]. PEDIATRIC PULMONOLOGY, 1993, 15 (03) : 183 - 186
  • [8] CARDIORESPIRATORY EFFECTS OF CHANGING INSPIRATORY TO EXPIRATORY RATIO DURING HIGH-FREQUENCY OSCILLATION IN AN ANIMAL-MODEL OF RESPIRATORY-FAILURE
    COURTNEY, SE
    WEBER, KR
    SPOHN, WA
    BENDER, CV
    MALIN, SW
    GOTSHALL, RW
    [J]. PEDIATRIC PULMONOLOGY, 1992, 13 (02) : 113 - 116
  • [9] MEASUREMENT OF LUNG-VOLUME AND OPTIMAL OXYGENATION DURING HIGH-FREQUENCY OSCILLATION
    DIMITRIOU, G
    GREENOUGH, A
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1995, 72 (03): : F180 - F183
  • [10] FROESE AB, 1987, AM REV RESPIR DIS, V135, P1363, DOI 10.1007/BF03009896