The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study

被引:47
作者
Chubb, Henry [1 ]
Karim, Rashed [1 ]
Roujol, Sebastien [1 ]
Nunez-Garcia, Marta [2 ]
Williams, Steven E. [1 ,3 ]
Whitaker, John [1 ]
Harrison, James [1 ,3 ]
Butakoff, Constantine [2 ]
Camara, Oscar [2 ]
Chiribiri, Amedeo [1 ,3 ]
Schaeffter, Tobias [1 ]
Wright, Matthew [1 ,3 ]
O'Neill, Mark [1 ,3 ]
Razavi, Reza [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, St Thomas Hosp, Westminster Bridge Rd, London SE1 7EH, England
[2] Univ Pompeu Fabra, Dept Informat & Commun Technol, PhySense, Barcelona, Spain
[3] St Thomas Hosp, Dept Cardiol, London, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
Atrial fibrillation; Cardiac magnetic resonance imaging; Catheter ablation; Atrium; Optimization; Late gadolinium enhancement; CATHETER ABLATION; PULMONARY VEIN; ENDOCARDIAL VOLTAGE; MRI; REGISTRATION; VALIDATION; RECURRENCE; LESIONS; INJURY; EXTENT;
D O I
10.1186/s12968-018-0438-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. Methods: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters ('Repro', n = 10), 3 T scanner ('3 T', n = 10), half-slice thickness ('Half-slice', n = 10) or half GBCA dose ('Half-gad', n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (% LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). Results: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: % LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for 'Repro' group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for % LA PAAS 0.454-0.825, PVE 0.618-0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, 'Repro' group). There was no significant relationship between indices of PAAS and AF recurrence. Conclusion: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome.
引用
收藏
页数:15
相关论文
共 36 条
[1]   MRI Assessment of Ablation-Induced Scarring in Atrial Fibrillation: Analysis from the DECAAF Study [J].
Akoum, Nazem ;
Wilber, David ;
Hindricks, Gerhard ;
Jais, Pierre ;
Cates, Josh ;
Marchlinski, Francis ;
Kholmovski, Eugene ;
Burgon, Nathan ;
Hu, Nan ;
Mont, Lluis ;
Deneke, Thomas ;
Duytschaever, Mattias ;
Neumann, Thomas ;
Mansour, Moussa ;
Mahnkopf, Christian ;
Hutchinson, Mathew ;
Herweg, Bengt ;
Daoud, Emile ;
Wissner, Erik ;
Brachmann, Johannes ;
Marrouche, Nassir F. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) :473-480
[2]   Evaluation of Left Atrial Lesions After Initial and Repeat Atrial Fibrillation Ablation Lessons Learned From Delayed-Enhancement MRI in Repeat Ablation Procedures [J].
Badger, Troy J. ;
Daccarett, Marcos ;
Akoum, Nazem W. ;
Adjei-Poku, Yaw A. ;
Burgon, Nathan S. ;
Haslam, Thomas S. ;
Kalvaitis, Saul ;
Kuppahally, Suman ;
Vergara, Gaston ;
McMullen, Lori ;
Anderson, Paul A. ;
Kholmovski, Eugene ;
MacLeod, Rob S. ;
Marrouche, Nassir F. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (03) :249-259
[3]   Temporal left atrial lesion formation after ablation of atrial fibrillation [J].
Badger, Troy J. ;
Oakes, Robert S. ;
Daccarett, Marcos ;
Burgon, Nathan S. ;
Akoum, Nazem ;
Fish, Eric N. ;
Blauer, Joshua J. E. ;
Rao, Swati N. ;
Adjei-Poku, Yaw ;
Kholmovski, Eugene G. ;
Vijayakumar, Sathya ;
Di Betta, Edward V. R. ;
MacLeod, Rob S. ;
Marrouche, Nassir F. .
HEART RHYTHM, 2009, 6 (02) :161-168
[4]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[5]   Left atrial fibrosis quantification by late gadolinium-enhanced magnetic resonance: a new method to standardize the thresholds for reproducibility [J].
Benito, Eva M. ;
Carlosena-Remirez, Alicia ;
Guasch, Eduard ;
Prat-Gonzalez, Susana ;
Perea, Rosario J. ;
Figueras, Rosa ;
Borras, Roger ;
Andreu, David ;
Arbelo, Elena ;
Maria Tolosana, J. ;
Bisbal, Felipe ;
Brugada, Josep ;
Berruezo, Antonio ;
Mont, Lluis .
EUROPACE, 2017, 19 (08) :1272-1279
[6]   CMR-Guided Approach to Localize and Ablate Gaps in Repeat AF Ablation Procedure [J].
Bisbal, Felipe ;
Guiu, Esther ;
Cabanas-Grandio, Pilar ;
Berruezo, Antonio ;
Prat-Gonzalez, Susana ;
Vidal, Barbara ;
Garrido, Cesar ;
Andreu, David ;
Fernandez-Armenta, Juan ;
Maria Tolosana, Jose ;
Arbelo, Elena ;
de Caralt, Teresa M. ;
Perea, Rosario J. ;
Brugada, Josep ;
Mont, Lluis .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (07) :653-663
[7]   2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design [J].
Calkins, Hugh ;
Kuck, Karl Heinz ;
Cappato, Riccardo ;
Brugada, Josep ;
Camm, A. John ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
DiMarco, John ;
Edgerton, James ;
Ellenbogen, Kenneth ;
Ezekowitz, Michael D. ;
Haines, David E. ;
Haissaguerre, Michel ;
Hindricks, Gerhard ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jalife, Jose ;
Jais, Pierre ;
Kalman, Jonathan ;
Keane, David ;
Kim, Young-Hoon ;
Kirchhof, Paulus ;
Klein, George ;
Kottkamp, Hans ;
Kumagai, Koichiro ;
Lindsay, Bruce D. ;
Mansour, Moussa ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koonlawee ;
Nakagawa, Hiroshi ;
Natale, Andrea ;
Nattel, Stanley ;
Packer, Douglas L. ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Reddy, Vivek ;
Ruskin, Jeremy N. ;
Shemin, Richard J. ;
Tsao, Hsuan-Ming ;
Wilber, David ;
Ad, Niv ;
Cummings, Jennifer ;
Gillinov, A. Mark ;
Heidbuchel, Hein .
EUROPACE, 2012, 14 (04) :528-606
[8]   Generalized overlap measures for evaluation and validation in medical image analysis [J].
Crum, William R. ;
Camara, Oscar ;
Hill, Derek L. G. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) :1451-1461
[9]   High-throughput gadobutrol-enhanced CMR: a time and dose optimization study [J].
D'Angelo, Tommaso ;
Grigoratos, Chrysanthos ;
Mazziotti, Silvio ;
Bratis, Konstantinos ;
Pathan, Faraz ;
Blandino, Alfredo ;
Elen, Elen ;
Puntmann, Valentina O. ;
Nagel, Eike .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
[10]   Comparison and evaluation of rigid, affine, and nonrigid registration of breast MR images [J].
Denton, ERE ;
Sonoda, LI ;
Rueckert, D ;
Rankin, SC ;
Hayes, C ;
Leach, MO ;
Hill, DLG ;
Hawkes, DJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (05) :800-805