Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate

被引:8
|
作者
Bird, Nicholas J. [1 ]
Peters, Christina [1 ]
Michell, A. Robert [2 ]
Peters, A. Michael [1 ]
机构
[1] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[2] St Bartholomews Med Sch, William Harvey Res Inst, Dept Biochem Pharmacol, London, England
关键词
Cr-51-ethylenediaminetetraacetic acid; glomerular filtration rate; iohexol; single sample; validation;
D O I
10.1097/MNM.0b013e328310b378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim To develop a strategy for checking the reliability of slope intercept measurement of glomerular filtration rate (GFR). Methods Six blood samples, obtained bilaterally 20-240 min after the injection of Cr-51-ethylenediaminetetraacetic acid (EDTA) and iohexol into opposite arms, were assayed for indicator injected contralaterally. GFR6(iohexol), the reference value, was measured for all six samples and GFR3(EDTA) (slope-intercept) for the last three samples (per 1.73 m(2)). GFR was measured from the half-time [GFR/extracellular fluid volume (ECV)3(EDTA)], for the single samples at 2-4h (Christensen-Groth; GFR1) and for creatinine [estimated GFR (eGFR)]. Results In six of the 97 studies, the correlation coefficient W of the fit to the last three sample points was less than 0.99. In the remaining 91 studies, GFR3(EDTA) disagreed with GFR/ECVEDTA by more than 15% in 19 studies (group A) and by less than 15% in 72 studies (group 13). GFR3(EDTA) disagreed with GFR6(iohexol) by 12.6% in group A but only by 6.3% in group B (P < 0.001). No such discrimination was displayed by eGFR. Although GFR3(EDTA) was within 15% of GFR6(iohexol) in 14 group A studies, eGFR was within 15% of GFR3(EDTA) in only eight studies and disagreed by more than 15% in six studies. Conversely, in the five of the 19 studies in which GFR3(EDTA) disagreed with GFR6(iohexol) by more than 15%, the agreement between eGFR and GFR3(EDTA) Was less than 15% in two studies and more than 15% in three studies. GFR3(EDTA) was within 15% of GFR/ECV3(EDTA) in all six studies in which r was less than 0.99, and GFR3(EDTA) disagreed with GFR6(iohexol) by less than 15%. Confidence in GFR3(EDTA) was not improved by GFR1 or eGFR. Conclusion Slope intercept GFR is reliable if within 15% of GFR/ECV3. Estimated GFR was ineffective as a second checkpoint. GFR1 did not help when the fit was poor. Nucl Med Commun 29:1086-1092 (c) 2008 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1086 / 1092
页数:7
相关论文
共 50 条
  • [41] Variability of estimated glomerular filtration rate and 99mTc-DTPA glomerular filtration rate: implications for a single time-point sampling regime
    Bonney, Lara M.
    McGowan, Daniel R.
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (05) : 351 - 357
  • [42] Update on Assessment of Estimated Glomerular Filtration Rate in Patients With Cirrhosis
    Griffin, Connor
    Asrani, Sumeet K.
    Regner, Kevin R.
    ADVANCES IN KIDNEY DISEASE AND HEALTH, 2023, 30 (04): : 307 - 314
  • [43] Blood Cadmium and Estimated Glomerular Filtration Rate in Korean Adults
    Hwangbo, Young
    Weaver, Virginia M.
    Tellez-Plaza, Maria
    Guallar, Eliseo
    Lee, Byung-Kook
    Navas-Acien, Ana
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2011, 119 (12) : 1800 - 1805
  • [44] Gestational Estimated Glomerular Filtration Rate and Adverse Maternofetal Outcomes
    Park, Sehoon
    Lee, Seung Mi
    Park, Joong Shin
    Hong, Joon-Seok
    Chin, Ho Jun
    Na, Ki Young
    Kim, Dong Ki
    Oh, Kook-Hwan
    Joo, Kwon Wook
    Kim, Yon Su
    Lee, Hajeong
    KIDNEY & BLOOD PRESSURE RESEARCH, 2018, 43 (05) : 1688 - 1698
  • [45] Measured and Estimated Glomerular Filtration Rate in the ICU: A Prospective Study
    Sangla, Frederic
    Marti, Pierre Emmanuel
    Verissimo, Thomas
    Pugin, Jerome
    de Seigneux, Sophie
    Legouis, David
    CRITICAL CARE MEDICINE, 2020, 48 (12) : E1232 - E1241
  • [46] Reduced estimated glomerular filtration rate in Alzheimer's disease
    Kerr, Enda
    Craig, David
    McGuinness, Bernadette
    Dynan, Kevin B.
    Fogarty, Damian
    Johnston, Janet A.
    Passmore, A. Peter
    INTERNATIONAL JOURNAL OF GERIATRIC PSYCHIATRY, 2009, 24 (09) : 927 - 932
  • [47] Validation of estimated glomerular filtration rate equations for Japanese children
    Yoshimitsu Gotoh
    Osamu Uemura
    Kenji Ishikura
    Tomoyuki Sakai
    Yuko Hamasaki
    Yoshinori Araki
    Riku Hamda
    Masataka Honda
    Clinical and Experimental Nephrology, 2018, 22 : 931 - 937
  • [48] Validation of estimated glomerular filtration rate equations for Japanese children
    Gotoh, Yoshimitsu
    Uemura, Osamu
    Ishikura, Kenji
    Sakai, Tomoyuki
    Hamasaki, Yuko
    Araki, Yoshinori
    Hamda, Riku
    Honda, Masataka
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2018, 22 (04) : 931 - 937
  • [49] Glomerular Hypertrophy and Initial Dip in Estimated Glomerular Filtration Rate Following Dapagliflozin Administration
    Shimizu, Akihiro
    Tsuboi, Nobuo
    Sasaki, Takaya
    Haruhara, Kotaro
    Matsumoto, Kei
    Ueda, Hiroyuki
    Yokote, Shinya
    Okabe, Masahiro
    Hatanaka, Saeko
    Ikeda, Masato
    Yokoo, Takashi
    KIDNEY INTERNATIONAL REPORTS, 2024, 9 (07): : 2282 - 2285
  • [50] Impact of creatinine measurement on glomerular filtration rate estimation
    Pennacchiotti, Graciela
    Benozzi, Silvia
    Ruiz, Gustavo
    Berger, Claudio
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2012, 46 (02): : 205 - 211