Congenital Aortic Stenosis: A Novel Technique for Ventricular Pacing During Valvuloplasty

被引:25
作者
Karagoez, Tevfik [1 ]
Aypar, Ebru [1 ]
Erdogan, Ilkay [1 ]
Sahin, Murat [1 ]
Oezer, Sema [1 ]
Celiker, Alpay [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Pediat, Cardiol Sect, TR-06100 Ankara, Turkey
关键词
congenital heart disease; balloon dilatation; interventional catheterization; ventricular stimulation; aortic valve stenosis;
D O I
10.1002/ccd.21695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The main objective of this study is to describe a new technique for rapid ventricular pacing to maintain balloon stability during balloon aortic valvuloplasty (BAV) without using transvenous temporary pacemaker electrode. Background: The safety and efficacy of rapid right ventricular pacing to facilitate balloon stability during BAV has been previously reported. However, it necessitates an additional femoral venous access, an additional sheath, and a temporary pacemaker electrode. Methods: This was a prospective pilot study. Rapid ventricular pacing was performed through backup guidewires inserted into the left ventricle for balloon advancement and by an adhesive patch placed on the back of the patient. The technique was performed during BAV procedure in all of 15 consecutive children diagnosed as congenital aortic stenosis. Pacing was performed at a rate decreasing systolic aortic pressure to the point of 40-50% of baseline. Results: The technique was successful in all patients. Effective capture, stable pacing, and balloon stability were achieved in all children using very low outputs. No sustained arrhythmias or other procedure-related complications occurred. Mean aortic valve gradient decreased from 68.5 +/- 20.4 mm Hg to 20.4 +/- 10.2 mm Hg. Degree of aortic regurgitation progressed from grade 0 to 1 in three patients and remained unchanged in 12 patients. Conclusions: This study demonstrated that backup guidewires can be used effectively and safely for pacing during BAV procedures. This technique omits probable complications related to a second vascular access and may shorten the procedure time and decreases costs by eliminating the use of an additional sheath and a temporary pacemaker electrode. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:527 / 530
页数:4
相关论文
共 9 条
[1]  
Borghi A, 1999, Heart, V82, pe10
[2]   Rapid right ventricular pacing is an alternative to adenosine in catheter interventional procedures for congenital heart disease [J].
Daehnert, I ;
Rotzsch, C ;
Wiener, M ;
Schneider, P .
HEART, 2004, 90 (09) :1047-1050
[3]   Cardiac pacing in balloon aortic valvuloplasty [J].
David, Felipe ;
Sanchez, Agustin ;
Yanez, Lucelly ;
Velasquez, Enrique ;
Jimenez, Santiago ;
Martinez, Arturo ;
Alva, Carlos .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 116 (03) :327-330
[4]   Adenosine induced transient cardiac standstill in catheter interventional procedures for congenital heart disease [J].
De Giovanni, JV ;
Edgar, RA ;
Cranston, A .
HEART, 1998, 80 (04) :330-333
[5]  
De Wolf D, 2006, ACTA CARDIOL, V61, P204
[6]   QUANTITATIVE EVALUATION OF CINEAORTOGRAPHY IN ASSESSMENT OF AORTIC REGURGITATION [J].
HUNT, D ;
BAXLEY, WA ;
KENNEDY, JW ;
JUDGE, TP ;
WILLIAMS, JE ;
DODGE, HT .
AMERICAN JOURNAL OF CARDIOLOGY, 1973, 31 (06) :696-700
[7]  
ING FF, 2001, PROG PEDIATR CARDIOL, V14, P13
[8]  
Kuhn MA, 1996, CATHETER CARDIO DIAG, V39, P55
[9]   Current treatments for congenital aortic stenosis [J].
McLean, Kelly M. ;
Lorts, Angela ;
Pearl, Jeffrey M. .
CURRENT OPINION IN CARDIOLOGY, 2006, 21 (03) :200-204