A Computer-Aided Diagnosis System to Detect Pathologies in Temporal Subtraction Images of Chest Radiographs

被引:0
作者
Looper, Jared [1 ,3 ]
Harrison, Melanie [2 ,3 ]
Armato, Samuel G., III [3 ]
机构
[1] Univ Texas Dallas, Richardson, TX 75083 USA
[2] Lewis Univ, Romeoville, IL USA
[3] Univ Chicago, Chicago, IL 60637 USA
来源
MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS | 2015年 / 9785卷
关键词
temporal subtraction; computer-aided diagnosis; synthetic minority oversampling; forward feature selection; texture features;
D O I
10.1117/12.2217105
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Radiologists often compare sequential radiographs to identify areas of pathologic change; however, this process is prone to error, as human anatomy can obscure the regions of change, causing the radiologists to overlook pathology. Temporal subtraction (TS) images can provide enhanced visualization of regions of change in sequential radiographs and allow radiologists to better detect areas of change in radiographs. Not all areas of change shown in TS images, however, are actual pathology. The purpose of this study was to create a computer-aided diagnostic (CAD) system that identifies which regions of change are caused by pathology and which are caused by misregistration of the radiographs used to create the TS image. The dataset used in this study contained 120 images with 74 pathologic regions on 54 images outlined by an experienced radiologist. High and low ("light" and "dark") gray-level candidate regions were extracted from the images using gray-level thresholding. Then, sampling techniques were used to address the class imbalance problem between "true" and "false" candidate regions. Next, the datasets of light candidate regions, dark candidate regions, and the combined set of light and dark candidate regions were used as training and testing data for classifiers by using five-fold cross validation. Of the classifiers tested (support vector machines, discriminant analyses, logistic regression, and k-nearest neighbors), the support vector machine on the combined candidates using synthetic minority oversampling technique (SMOTE) performed best with an area under the receiver operating characteristic curve value of 0.85, a sensitivity of 85%, and a specificity of 84%.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Deformable image registration for temporal subtraction of chest radiographs
    Li, Min
    Castillo, Edward
    Luo, Hong-Yan
    Zheng, Xiao-Lin
    Castillo, Richard
    Meshkov, Dmitriy
    Guerrero, Thomas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (04) : 513 - 522
  • [32] A global registration method for temporal subtraction of chest radiographs
    He, Lifeng
    Inaba, Takeshi
    Suzuki, Kenji
    Murakami, Kazuhito
    Chao, Yuyan
    Tang, Wei
    Shi, Zhenghao
    Nakamura, Tsuyoshi
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND PATTERN RECOGNITION IN INDUSTRIAL ENGINEERING, 2010, 7820
  • [33] Clinical usefulness of temporal subtraction on digital chest radiographs
    Nakata, H
    Nakamura, K
    Uozumi, T
    Watanabe, H
    Aoki, T
    Katsuragawa, S
    Doi, K
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 793 - 797
  • [34] Deformable image registration for temporal subtraction of chest radiographs
    Min Li
    Edward Castillo
    Hong-Yan Luo
    Xiao-Lin Zheng
    Richard Castillo
    Dmitriy Meshkov
    Thomas Guerrero
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 513 - 522
  • [35] Temporal subtraction of dual-energy chest radiographs
    Armato, Samuel G., III
    Doshi, Devang J.
    Engelmann, Roger
    Caligiuri, Philip
    MacMahon, Heber
    MEDICAL PHYSICS, 2006, 33 (06) : 1911 - 1919
  • [36] Computer-aided diagnosis system for lung tumors
    Suzuki, H
    Inaoka, N
    Takabatake, H
    Mori, M
    Natori, H
    MEDICAL IMAGING 1996: IMAGE PROCESSING, 1996, 2710 : 1035 - 1038
  • [37] Effect of the number of cases in image database on the performance of computer-aided diagnosis (CAD) for the detection of pulmonary nodules in chest radiographs
    Shiraishi, J
    Abe, H
    Engelmann, R
    Bae, KT
    Doi, K
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 177 - 182
  • [38] Temporal subtraction of chest radiographs compensating pose differences
    von Berg, Jens
    Dworzak, Jalda
    Klinder, Tobias
    Manke, Dirk
    Kreth, Adrian
    Lamecker, Hans
    Zachow, Stefan
    Lorenz, Cristian
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [39] Application of temporal subtraction to screening chest radiographs with a mobile computed radiography system
    Katsuragawa, S
    Sasaki, Y
    MacMahon, H
    Ishida, T
    Doi, K
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 51 - 56
  • [40] A Computer-Aided Diagnosis System of Nuclear Cataract
    Li, Huiqi
    Lim, Joo Hwee
    Liu, Jiang
    Mitchell, Paul
    Tan, Ava Grace
    Wang, Jie Jin
    Wong, Tien Yin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (07) : 1690 - 1698