A Computer-Aided Diagnosis System to Detect Pathologies in Temporal Subtraction Images of Chest Radiographs

被引:0
|
作者
Looper, Jared [1 ,3 ]
Harrison, Melanie [2 ,3 ]
Armato, Samuel G., III [3 ]
机构
[1] Univ Texas Dallas, Richardson, TX 75083 USA
[2] Lewis Univ, Romeoville, IL USA
[3] Univ Chicago, Chicago, IL 60637 USA
来源
MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS | 2015年 / 9785卷
关键词
temporal subtraction; computer-aided diagnosis; synthetic minority oversampling; forward feature selection; texture features;
D O I
10.1117/12.2217105
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Radiologists often compare sequential radiographs to identify areas of pathologic change; however, this process is prone to error, as human anatomy can obscure the regions of change, causing the radiologists to overlook pathology. Temporal subtraction (TS) images can provide enhanced visualization of regions of change in sequential radiographs and allow radiologists to better detect areas of change in radiographs. Not all areas of change shown in TS images, however, are actual pathology. The purpose of this study was to create a computer-aided diagnostic (CAD) system that identifies which regions of change are caused by pathology and which are caused by misregistration of the radiographs used to create the TS image. The dataset used in this study contained 120 images with 74 pathologic regions on 54 images outlined by an experienced radiologist. High and low ("light" and "dark") gray-level candidate regions were extracted from the images using gray-level thresholding. Then, sampling techniques were used to address the class imbalance problem between "true" and "false" candidate regions. Next, the datasets of light candidate regions, dark candidate regions, and the combined set of light and dark candidate regions were used as training and testing data for classifiers by using five-fold cross validation. Of the classifiers tested (support vector machines, discriminant analyses, logistic regression, and k-nearest neighbors), the support vector machine on the combined candidates using synthetic minority oversampling technique (SMOTE) performed best with an area under the receiver operating characteristic curve value of 0.85, a sensitivity of 85%, and a specificity of 84%.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Computer-aided diagnosis workstation and database system for chest diagnosis based on multihelical CT images
    Sato, H
    Niki, N
    Mori, K
    Eguchi, K
    Kaneko, M
    Moriyama, N
    Ohmatsu, H
    Kakinuma, R
    Masuda, H
    Machida, S
    Sasagawa, M
    MEDICAL IMAGING 2004: PACS AND IMAGING INFORMATICS, 2004, 5 (25): : 402 - 412
  • [22] Computer-aided diagnosis for pneumoconiosis based on texture analysis on digital chest radiographs
    Cai, Chunxiao
    Zhu, Biyun
    Chen, Hui
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 244 - +
  • [23] Intelligent computer-aided diagnosis system for chest radiography
    Park, M
    Jin, JS
    Wilson, LS
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1005 - 1010
  • [24] COMPUTER-AIDED DIAGNOSIS SCHEME FOR ANALYSIS OF LUNG TEXTURE ON CLINICAL CHEST RADIOGRAPHS
    CHEN, X
    DOI, K
    ABE, K
    MACMAHON, H
    KATSURAGAWA, S
    RADIOLOGY, 1992, 185 : 300 - 300
  • [25] Temporal subtraction for the detection of ground-glass shadow on chest radiographs: Evaluation of the usefulness of the first commercially available robustic computer-aided diagnostic system
    Tsubamoto, M
    Johkoh, T
    Hamada, S
    Honda, O
    Nakamura, H
    Fujiwara, K
    RADIOLOGY, 2001, 221 : 546 - 546
  • [26] Temporal subtraction for the detection of ground-glass shadow on chest radiographs: Evaluation of the first commercially available robustic computer-aided diagnostic system.
    Johkoh, T
    Tsubamoto, M
    Kozuka, T
    Tomiyama, N
    Hamada, S
    Honda, O
    Koyama, M
    Nakamura, H
    Fujiwara, K
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1107 - 1107
  • [27] Computer-aided diagnosis workstation for chest diagnosis based on multihelical CT images
    Sato, H
    Niki, N
    Mori, K
    Eguchi, K
    Kaneko, M
    Kakinuma, R
    Moriyama, N
    Ohmatsu, H
    Masuda, H
    Machida, S
    Sasagawa, M
    MEDICAL IMAGING 2005: PACS AND IMAGING INFORMATICS, 2005, 5748 : 480 - 490
  • [28] COMPUTER-AIDED DIAGNOSIS IN CHEST RADIOLOGY
    MACMAHON, H
    DOI, K
    CHAN, HP
    GIGER, ML
    KATSURAGAWA, S
    NAKAMORI, N
    JOURNAL OF THORACIC IMAGING, 1990, 5 (01) : 67 - 76
  • [29] Computer-aided diagnosis in chest radiology
    Abe, H
    MacMahon, H
    Shiraishi, J
    Li, Q
    Engelmann, R
    Doi, K
    SEMINARS IN ULTRASOUND CT AND MRI, 2004, 25 (05) : 432 - 437
  • [30] COMPUTER-AIDED DIAGNOSIS IN CHEST RADIOGRAPHY
    DOI, K
    MACMAHON, H
    KATSURAGAWA, S
    XU, X
    GIGER, ML
    RADIOLOGY, 1995, 197 : 538 - 538