Use of the photoelastic method and finite element analysis in the assessment of wall strain in abdominal aortic aneurysm models

被引:25
|
作者
Doyle, Barry J. [1 ,2 ,3 ]
Killion, John [1 ,2 ,4 ]
Callanan, Anthony [1 ,2 ]
机构
[1] Univ Limerick, Ctr Appl Biomed Engn Res CABER, Dept Mech Aeronaut & Biomed Engn, Limerick, Ireland
[2] Univ Limerick, Mat & Surface Sci Inst, Limerick, Ireland
[3] Univ Edinburgh, Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
[4] Athlone Inst Technol, Mat Res Inst, Athlone, Ireland
关键词
Abdominal aortic aneurysm; Photoelastic method; FEA; Biomechanics; Strain; Validation; RUPTURE LOCATIONS; STRESS; IDENTIFICATION; DIAMETER; RISK;
D O I
10.1016/j.jbiomech.2012.05.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Abdominal aortic aneurysm (AAA) is a significant health problem. Current clinical rupture-risk relies primarily on the maximum diameter of the AAA and also growth rate. However, AAAs are a patient-specific problem and recently, numerical tools have been employed to estimate rupture-potential. Alternatively, experimental assessment of AAA biomechanics receives less attention, yet, rigorous validation of numerical tools is required prior to clinical acceptance. This paper examines the use of the photoelastic method to assess wall strain and its validation using finite element analysis (FEA) in a small number of patient-specific AAA models. Experimental models were manufactured in-house using the injection-moulding procedure together with a commercially available photoelastic material. The material was mechanically characterised prior to testing, with models examined under three loading regimes (80, 120 and 160 mmHg). Each experimental model was imaged using computed tomography (CT) and reconstructed in three dimensions (3D) for numerical analyses. Experimental wall strain was measured and numerical wall strain calculated with finite element analysis (FEA). Results were qualitatively and quantitatively compared. There was good qualitative agreement between the experimental and numerical methods, with similar trends apparent throughout all models at all pressures. Overall, acceptable percentage errors between the techniques were observed for all models. Median errors of -6.5%, -0.4% and 3.9% for the models at 80, 120 and 160 mmHg pressures, respectively, were determined. The photoelastic method is a very useful experimental tool that provides instant, easy to interpret, information regarding wall strain. The technique is useful for validation of numerical AAA studies. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1759 / 1768
页数:10
相关论文
共 50 条
  • [1] USE OF THE PHOTOELASTIC METHOD TO DETERMINE THE WALL STRESS IN REALISTIC ABDOMINAL AORTIC ANEURYSM MODELS
    Doyle, Barry J.
    Callanan, Anthony
    Killion, John
    McGloughlin, Timothy M.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2011, PTS A AND B, 2011, : 61 - 62
  • [2] Finite element and photoelastic modelling of an abdominal aortic aneurysm: a comparative study
    Callanan, Anthony
    Morris, Liam G.
    McGloughlin, Tim M.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (10) : 1111 - 1119
  • [3] Local wall thickness in finite element models improves prediction of abdominal aortic aneurysm growth
    Shang, Eric K.
    Nathan, Derek P.
    Woo, Edward Y.
    Fairman, Ronald M.
    Wang, Grace J.
    Gorman, Robert C.
    Gorman, Joseph H., III
    Jackson, Benjamin M.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 217 - 223
  • [4] Local Wall Thickness in Finite Element Models Improves Prediction of Abdominal Aortic Aneurysm Growth
    Shang, Eric K.
    Nathan, Derek P.
    Fairman, Ronald M.
    Woo, Edward Y.
    Wang, Grace J.
    Gorman, Robert C.
    Gorman, Joseph H., III
    Jackson, Benjamin M.
    JOURNAL OF VASCULAR SURGERY, 2013, 57 (05) : 78S - 79S
  • [5] Finite element model of abdominal aortic aneurysm
    Bursa, J.
    Mucha, P.
    Skacel, P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 185 - 188
  • [6] VISUALIZATION AND FINITE-ELEMENT ANALYSIS OF PULSATILE FLOW IN MODELS OF THE ABDOMINAL AORTIC-ANEURYSM
    FUKUSHIMA, T
    MATSUZAWA, T
    HOMMA, T
    BIORHEOLOGY, 1989, 26 (02) : 109 - 130
  • [7] Biomechanical analysis with finite element analysis of abdominal aortic aneurysm, a promising tool for rupture risk assessment
    Soto Carricas, B.
    Escudero Rodriguez, J. R.
    ANGIOLOGIA, 2015, 67 (03): : 237 - 239
  • [8] Strain Patterns With Ultrasound for Assessment of Abdominal Aortic Aneurysm Vessel Wall Biomechanics
    Lorenzen, Ulver S.
    Bracco, Marta I.
    Zielinski, Alexander H.
    Broda, Magdalena
    Avril, Stephane
    Rouet, Laurence
    Eiberg, Jonas P.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (01): : 112 - 119
  • [9] In vivo strain assessment of the abdominal aortic aneurysm
    Satriano, Alessandro
    Rivolo, Simone
    Martufi, Giampaolo
    Finol, Ender A.
    Di Martino, Elena S.
    JOURNAL OF BIOMECHANICS, 2015, 48 (02) : 354 - 360
  • [10] Explicit finite element method for in-vivo mechanics of abdominal aortic aneurysm
    Gasbarro, Michelle D.
    Shimada, Kenji
    Di Martino, Elena S.
    EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2007, 16 (3-4): : 337 - 363