Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy Chain

被引:25
作者
Lalande, A. [1 ]
Van Kien, P. Khau [2 ]
Walker, P. M. [1 ]
Zhu, L. [3 ]
Legrand, L. [1 ]
Claustres, M. [2 ]
Jeunemaitre, X. [3 ]
Brunotte, F. [1 ]
Wolf, J. E. [1 ]
机构
[1] Univ Bourgogne, Grp Imagerie Med, LE21, Fac Med Dijon,CNRS,UMR 5158, F-21079 Dijon, France
[2] CHU Montpellier, Inst Univ Rech Clin, Genet Mol Lab, INSERM,U827, Montpellier, France
[3] Coll France, INSERM, U772, F-75231 Paris, France
关键词
aorta; elasticity; magnetic resonance imaging; pulse wave velocity; genetics;
D O I
10.1002/jmri.21565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods: Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M-) of similar age, sex, and blood pressure characteristics. Results: Despite a similar aortic diameter in both groups. the aortic compliance and distensibility were significantly lower in M+ subjects compared with M- (0.84 +/- 0.33 versus 2.03 +/- 0.54 mm(2)/mmHg. 1.18 +/- 0.62 10(-3) versus 5.11 +/- 1.58 10(-3) mmHg(-1), respectively), and PWV was significantly higher (5.35 +/- 1.53 versus 3.60 +/- 0.64 m. s(-1)). A threshold aortic compliance value of 1.3 mm(2)/mmHg separated the two groups. The receiver operating characteristics curve analysis indicated an optimal threshold of 2.9 10(-3) mmHg(-1) for aortic distensibility (sensitivity: 87.5%, specificity: 90%), and of 4.4 m.s(-1) for PWV (sensitivity: 75%, specificity: 100%). Conclusion: Young asymptomatic adults with MYH11 mutation have an aortic compliance impairment which is not detectable by the sole measurement of the aortic size. Aortic compliance measurement might be part of routine examination in patients suspected of inherited aortic disease even with a normal aortic diameter.
引用
收藏
页码:1180 / 1187
页数:8
相关论文
共 39 条
[21]   Clinical value of aortic pulse-wave velocity measurement [J].
Lehmann, ED .
LANCET, 1999, 354 (9178) :528-529
[22]   REGIONAL PULSE-WAVE VELOCITY IN ARTERIAL TREE [J].
MCDONALD, DA .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (01) :73-&
[23]   Epidemiology and clinicopathology of aortic dissection -: A population-based longitudinal study over 27 years [J].
Mészáros, I ;
Mórocz, J ;
Szlávi, J ;
Schmidt, J ;
Tornóci, L ;
Nagy, L ;
Szép, L .
CHEST, 2000, 117 (05) :1271-1278
[24]   The clinical significance of aortic compliance and its assessment with magnetic resonance imaging [J].
Metafratzi, ZM ;
Efremidis, SC ;
Skopelitou, AS ;
De Roos, A .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (04) :481-491
[25]   BASIC PRINCIPLES OF ROC ANALYSIS [J].
METZ, CE .
SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) :283-298
[26]  
MOHIADDIN RH, 1989, BRIT HEART J, V62, P90
[27]   AGE-RELATED-CHANGES OF HUMAN AORTIC FLOW WAVE VELOCITY MEASURED NONINVASIVELY BY MAGNETIC-RESONANCE-IMAGING [J].
MOHIADDIN, RH ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (01) :492-497
[28]  
Murai Sachiko, 2005, Radiat Med, V23, P236
[29]   Clinical applications of arterial stiffness; definitions and reference values [J].
O'Rourke, MF ;
Staessen, JA ;
Vlachopoulos, C ;
Duprez, D ;
Plante, GE .
AMERICAN JOURNAL OF HYPERTENSION, 2002, 15 (05) :426-444
[30]   Receiver operating characteristic curves and their use in radiology [J].
Obuchowski, NA .
RADIOLOGY, 2003, 229 (01) :3-8