Performance limits of monolithic and packed capillary columns in high-performance liquid chromatography and capillary electrochromatography

被引:63
作者
Eeltink, S
Desmet, G
Vivó-Truyols, G
Rozing, GP
Schoenmakers, PJ
Kok, WT
机构
[1] Univ Amsterdam, Polymer Anal Grp, Van Hoff Inst Mol Sci, NL-1018 WV Amsterdam, Netherlands
[2] Free Univ Brussels, Dept Chem Engn, B-1050 Brussels, Belgium
[3] Agilent Technol, Pharmaceut Solut, Life Sci & Chem Anal, D-76337 Waldbronn, Germany
关键词
column characterization; performance limits; microparticulate columns; silica monoliths; metbacrylate monoliths; efficiency;
D O I
10.1016/j.chroma.2005.11.112
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method is proposed for the comprehensive characterization and comparison of columns in the high-performance liquid chromatographic (HPLC) and capillary electrochromatographic (CEC) modes. Using this approach, column parameters such as the number of plates, the eddy-diffusion and mass-transfer contributions to peak broadening, the permeability, and the analysis time are incorporated in a single graph and a comparison in terms of efficiency and speed is obtained. The chromatographic performance of silica-based and polymer-based monolithic capillary columns is discussed and a comparison is made with the performance of packed columns. Also, the potential of ultra-high-pressure liquid chromatography is discussed in this context. In the HPLC mode, the best results were obtained with silica monoliths; in the CEC mode, the low-density methacrylate-ester-based monoliths showed the best performance. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 262
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[3]  
Desmet G, 2005, LC GC EUR, V18, P403
[4]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070
[5]   Tailoring the morphology of methacrylate ester-based monoliths for optimum efficiency in liquid chromatography [J].
Eeltink, S ;
Herrero-Martinez, JM ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7342-7347
[6]   Comparison of the efficiency of microparticulate and monolithic capillary columns [J].
Eeltink, S ;
Decrop, WMC ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (17-18) :1431-1440
[7]   Study of the influence of the aspect ratio on efficiency, flow resistance and retention factors of packed capillary columns in pressure- and electrically-driven liquid chromatography [J].
Eeltink, S ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :311-316
[8]   Practical aspects of fast reversed-phase high-performance liquid chromatography using 3 μm particle packed columns and monolithic columns in pharmaceutical development and production working under current good manufacturing practice [J].
Gerber, F ;
Krummen, M ;
Potgeter, H ;
Roth, A ;
Siffrin, C ;
Spoendlin, C .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (02) :127-133
[9]   Comparison of the adsorption equilibrium of a few low-molecular mass compounds on a monolithic and a packed column in reversed-phase liquid chromatography [J].
Gritti, F ;
Piatkowski, W ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :81-107
[10]   EFFECT OF COLUMN TO PARTICLE DIAMETER RATIO ON DISPERSION OF UNSORBED SOLUTES IN CHROMATOGRAPHY [J].
KNOX, JH ;
PARCHER, JF .
ANALYTICAL CHEMISTRY, 1969, 41 (12) :1599-&