Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

被引:14
|
作者
Jagirdar, Mrinal [1 ]
Pandelidis, Demis [2 ]
Pacak, Anna [2 ]
Worek, William [3 ]
Cetin, Sabri [4 ]
机构
[1] Eindhoven Univ Technol, Dept Chem Engn & Chem, Eindhoven, Netherlands
[2] Wroclaw Univ Sci & Technol, Dept Mech & Power Engn, 27 Wyspia Ski St, PL-50370 Wroclaw, Poland
[3] Argonne Natl Lab, 9700 S Cass Ave, Lemont, IL 60439 USA
[4] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60607 USA
关键词
Desiccant dehumidification; Mathematical modelling; Maisotsenko cycle; Indirect evaporative cooling; Desiccant coated heat exchanger; Air conditioning; LIQUID DESICCANT DEHUMIDIFICATION; MAISOTSENKO CYCLE HEAT; MASS-TRANSFER; NUMERICAL-ANALYSIS; EXCHANGERS; COUNTER; OPTIMIZATION;
D O I
10.1016/j.enconman.2020.113009
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 degrees C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 degrees C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 degrees C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COPth) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COPel) in most cases.
引用
收藏
页数:25
相关论文
共 50 条
  • [31] Study on Desiccant Air-Conditioning System for Livestock Application in Pakistan
    Niaz, Hassan
    Sultan, Muhammad
    Miyazaki, Takahiko
    Khan, Zahid M.
    2018 2ND INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE), 2018, : 19 - 22
  • [32] Investigation of operation performance of air carrying energy radiant air-conditioning system based on CFD and thermodynamic model
    Liu, Jia
    Gong, Guangcai
    Liu, Riming
    Peng, Pei
    BUILDING SIMULATION, 2018, 11 (06) : 1229 - 1243
  • [33] Improving Air Conditioning Performance With Circular Phase Change Materials Based Heat Storage
    Sao, Arun Kumar
    Arora, Arun
    Sahu, Mukesh Kumar
    ENERGY STORAGE, 2025, 7 (02)
  • [34] Performance optimization and comparison of two hybrid regeneration methods for absorption air-conditioning system
    Zhang, Wanshi
    Ding, Boqing
    Wu, Yunlei
    Li, Xiuwei
    Cheng, Feng
    Zhang, Xiaosong
    SOLAR ENERGY, 2023, 249 : 81 - 97
  • [35] Ideal mass transfer cycle and thermal performance optimization for liquid desiccant air conditioning system
    Zhang, Yin
    Xiong, Jianwu
    Mao, Gang
    Li, Jin
    RESULTS IN PHYSICS, 2024, 57
  • [36] Performance improvements evaluation of an automobile air conditioning system using CO2 - propane mixture as a refrigerant
    Yu, Binbin
    Wang, Dandong
    Liu, Cichong
    Jiang, Fuzheng
    Shi, Junye
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 172 - 181
  • [37] Performance evaluation of silica-gel based desiccant dehumidification unit for air-conditioning applications
    Siddique, Akash
    Sultan, Muhammad
    2019 3RD INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE), 2019, : 50 - 54
  • [38] Thermal performance of a novel air conditioning system using a liquid desiccant
    Oliveira, AC
    Afonso, CF
    Riffat, SB
    Doherty, PS
    APPLIED THERMAL ENGINEERING, 2000, 20 (13) : 1213 - 1223
  • [39] Air-conditioning System Energy Efficiency and Energy Consumption Evaluation
    Du, Xiaotong
    Cai, Wenjian
    Jia, Lei
    2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 1908 - 1913
  • [40] Experimental research on the influence of the air humidity conditions in an air conditioning system
    Sobrinho, Pedro Magalhaes
    Tuna, Celso Eduardo
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 49 : 152 - 159