摘要
Previous work reported that commercial dental composite resins containing a urethane-modified bisGMA (bisphenylglycidyl dimethacrylate)/TEGDMA (triethylene glycol dimethacrylate) (ubis) based monomer system showed a 10-fold reduction in the release of a bisGMA-derived product, bishydroxypropoxyphenyl propane (bisHPPP), as compared with that found for bisGMA/TEGDMA (bis) based composites after incubation with cholesterol esterase (CE). Unfortunately, these materials also differed substantially in filler type and content, making it impossible to directly relate any specific parameter to the differences in biodegradation levels. By controlling for filler content and type, the current study will seek to probe the biomolecular interactions between composite resin chemistry and esterase activity in order to help explain the observed differences in biodegradation levels between the ubis and bis resin systems. After 32 days of incubation, buffer and CE solutions were analyzed for degradation products using high-performance liquid chromatography, UV spectroscopy, and mass spectrometry. Both materials were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, and X-ray photoelectron spectroscopy. In the CE groups, the ubis system showed a 2.6- to 86-fold reduction (dependent on the product) in the amount of isolated products relative to the bis system (p < 0.01). Scanning electron microscopy data also demonstrated the relative stability of the ubis system and X-ray photoelectron spectroscopy analysis showed a higher content of the ester bond at the surface of the bis samples. Fourier transform infrared data showed that both resins had similar conversions. Because both systems were identical except for their monomer systems, it was concluded that changes in biostability were associated with chemistry. Crosslinking, hydrophobicity, and solubility all relate to ubis's pro-stability. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:233 / 246
页数:14
相关论文
共 46 条
  • [21] In-vivo degradation of polyurethanes: transmission-FTIR microscopic characterization of polyurethanes sectioned by cryomicrotomy
    McCarthy, SJ
    Meijs, GF
    Mitchell, N
    Gunatillake, PA
    Heath, G
    Brandwood, A
    Schindhelm, K
    [J]. BIOMATERIALS, 1997, 18 (21) : 1387 - 1409
  • [22] Selection of restorative materials in permanent teeth in general dental practice
    Mjör, IA
    Moorhead, JE
    Dahl, JE
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1999, 57 (05) : 257 - 262
  • [23] MUNK P, 1989, INTRO MACROMOLECULAR, P139
  • [24] MUNKSGAARD EC, 1990, SCAND J DENT RES, V98, P261
  • [25] Nomoto R, 1994, Dent Mater J, V13, P198
  • [26] Olea N, 1996, ENVIRON HEALTH PERSP, V104, P298, DOI 10.1289/ehp.96104298
  • [27] PETERS GH, 1974, CHEM SEPARATIONS MEA, P647
  • [28] PEUTZFELDT A, 1994, SCAND J DENT RES, V102, P73
  • [29] Pierre TS, 1986, Journal of Bioactive and Compatible Polymers, V1, P467, DOI 10.1177/088391158600100405
  • [30] CALIBRATION OF FTIR CONVERSION ANALYSIS OF CONTEMPORARY DENTAL RESIN COMPOSITES
    RUEGGEBERG, FA
    HASHINGER, DT
    FAIRHURST, CW
    [J]. DENTAL MATERIALS, 1990, 6 (04) : 241 - 249