Multiperspective Ultrasound Strain Imaging of the Abdominal Aorta

被引:30
作者
de Hoop, Hein [1 ,2 ]
Petterson, Niels J. [1 ]
van de Vosse, Frans N. [1 ]
van Sambeek, Marc R. H. M. [1 ,2 ]
Schwab, Hans-Martin [1 ]
Lopata, Richard G. P. [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Cardiovasc Biomech Grp, NL-5600 Eindhoven, Netherlands
[2] Catharina Hosp, Dept Vasc Surg, NL-5602 Eindhoven, Netherlands
基金
欧洲研究理事会;
关键词
Ultrasound; multiperspective; abdominal aorta; strain imaging; elastography; WALL STRESS-ANALYSIS; MECHANICAL-PROPERTIES; ANEURYSM; RUPTURE; PORCINE; QUANTIFICATION; BIOMECHANICS; RISK;
D O I
10.1109/TMI.2020.3003430
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Current decision-making for clinical intervention of abdominal aortic aneurysms (AAAs) is based on the maximum diameter of the aortic wall, but this does not provide patient-specific information on rupture risk. Ultrasound (US) imaging can assess both geometry and deformation of the aortic wall. However, low lateral contrast and resolution are currently limiting the precision of both geometry and local strain estimates. To tackle these drawbacks, a multiperspective scanning mode was developed on a dual transducer US system to perform strain imaging at high frame rates. Experimental imaging was performed on porcine aortas embedded in a phantom of the abdomen, pressurized in a mock circulation loop. US images were acquired with three acquisition schemes: Multiperspective ultrafast imaging, single perspective ultrafast imaging, and conventional line-by-line scanning. Image registration was performed by automatic detection of the transducer surfaces. Multiperspective images and axial displacements were compounded for improved segmentation and tracking of the aortic wall, respectively. Performance was compared in terms of image quality, motion tracking, and strain estimation. Multiperspective compound displacement estimation reduced the mean motion tracking error over one cardiac cycle by a factor 10 compared to conventional scanning. Resolution increased in radial and circumferential strain images, and circumferential signal-to-noise ratio (SNRe) increased by 10 dB. Radial SNRe is high in wall regions moving towards the transducer. In other regions, radial strain estimates remain cumbersome for the frequency used. In conclusion, multiperspective US imaging was demonstrated to improve motion tracking and circumferential strain estimation of porcine aortas in an experimental set-up.
引用
收藏
页码:3714 / 3724
页数:11
相关论文
共 50 条
  • [31] Imaging of infected (mycotic) aneurysms of the abdominal aorta
    Raymond, A.
    Fairise, A.
    Ropion-Michaux, H.
    Mathias, J.
    Laurent, V.
    Regent, D.
    FEUILLETS DE RADIOLOGIE, 2011, 51 (05) : 245 - 253
  • [32] 3-D motion tracking and vascular strain imaging using bistatic dual aperture ultrasound acquisitions
    de Hoop, Hein
    Maas, Esther
    Muller, Jan-Willem
    Schwab, Hans-Martin
    Lopata, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04)
  • [33] ENHANCING LATERAL CONTRAST USING MULTI-PERSPECTIVE ULTRASOUND IMAGING OF ABDOMINAL AORTAS
    Petterson, Niels J.
    Sambeek, Marc. R. H. M. van
    Vosse, Frans N. van de
    Lopata, Richard G. P.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03) : 535 - 545
  • [34] NONINVASIVE STRAIN IMAGING IN PULSATING VESSELS USING BEAM STEERED ULTRASOUND ACQUISITIONS
    Hansen, Hendrik H. G.
    Lopata, Richard G. P.
    Keijts, Michiel
    Idzenga, Tim
    de Korte, Chris L.
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1078 - 1081
  • [35] Noninvasive Measurement of Bladder Muscle Activity Using Radiofrequency Ultrasound Strain Imaging
    Idzenga, T.
    Farag, F.
    Heesakkers, J.
    Feitz, W.
    de Korte, C. L.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2229 - 2232
  • [36] QUANTITATIVE TIME-HARMONIC ULTRASOUND ELASTOGRAPHY OF THE ABDOMINAL AORTA AND INFERIOR VENA CAVA
    Schaafs, Lars-Arne
    Tzschaetzsch, Heiko
    Figiel, Christin
    van der Giet, Markus
    Reshetnik, Alexander
    Hamm, Bernd
    Sack, Ingolf
    Elgeti, Thomas
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09) : 2349 - 2355
  • [37] The Acute Abdominal Aorta
    Mellnick, Vincent M.
    Heiken, Jay P.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2015, 53 (06) : 1209 - +
  • [38] An Approach to Point-Of-Care Ultrasound Evaluation of the Abdominal Aorta
    Hartrich, Molly
    Eilbert, Wesley
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (199):
  • [39] Murine ultrasound imaging for circumferential strain analyses in the angiotensin II abdominal aortic aneurysm model
    Favreau, John T.
    Nguyen, Binh T.
    Gao, Ian
    Yu, Peng
    Tao, Ming
    Schneiderman, Jacob
    Gaudette, Glenn R.
    Ozaki, C. Keith
    JOURNAL OF VASCULAR SURGERY, 2012, 56 (02) : 462 - 469
  • [40] Strain imaging of corneal tissue with an ultrasound elasticity microscope
    Hollman, KW
    Emelianov, SY
    Neiss, JH
    Jotyan, G
    Spooner, GJR
    Juhasz, T
    Kurtz, RM
    O'Donnell, M
    CORNEA, 2002, 21 (01) : 68 - 73