Standardized voluntary force measurement in a lower extremity rehabilitation robot

被引:28
作者
Bolliger, Marc [1 ,2 ]
Banz, Raphael [1 ]
Dietz, Volker [1 ]
Luenenburger, Lars [1 ]
机构
[1] Balgrist Univ Hosp, Spinal Cord Injury Ctr, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Sensory Motor Syst Lab, Zurich, Switzerland
关键词
D O I
10.1186/1743-0003-5-23
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Isometric force measurements in the lower extremity are widely used in rehabilitation of subjects with neurological movement disorders (NMD) because walking ability has been shown to be related to muscle strength. Therefore muscle strength measurements can be used to monitor and control the effects of training programs. A new method to assess isometric muscle force was implemented in the driven gait orthosis (DGO) Lokomat. To evaluate the capabilities of this new measurement method, inter- and intra-rater reliability were assessed. Methods: Reliability was assessed in subjects with and without NMD. Subjects were tested twice on the same day by two different therapists to test inter-rater reliability and on two separate days by the same therapist to test intra-rater reliability. Results: Results showed fair to good reliability for the new measurement method to assess isometric muscle force of lower extremities. In subjects without NMD, intraclass correlation coefficients (ICC) for inter-rater reliability ranged from 0.72 to 0.97 and intra-rater reliability from 0.71 to 0.90. In subjects with NMD, ICC ranged from 0.66 to 0.97 for inter-rater and from 0.50 to 0.96 for intra-rater reliability. Conclusion: Inter- and intra-rater reliability of an assessment method for measuring maximal voluntary isometric muscle force of lower extremities was demonstrated. We suggest that this method is a valuable tool for documentation and controlling of the rehabilitation process in patients using a DGO.
引用
收藏
页数:8
相关论文
共 23 条
[1]  
[Anonymous], FDN CLIN RES APPL PR
[2]   Manual muscle testing: does it meet the standards of an adequate screening test? [J].
Bohannon, RW .
CLINICAL REHABILITATION, 2005, 19 (06) :662-667
[3]  
Colombo G, 2000, J REHABIL RES DEV, V37, P693
[4]   Driven gait orthosis for improvement of locomotor training in paraplegic patients [J].
Colombo, G ;
Wirz, M ;
Dietz, V .
SPINAL CORD, 2001, 39 (05) :252-255
[5]   Low intensity strength training for ambulatory stroke patients [J].
Cramp, M. C. ;
Greenwood, R. J. ;
Gill, M. ;
Rothwell, J. C. ;
Scott, O. M. .
DISABILITY AND REHABILITATION, 2006, 28 (13-14) :883-889
[6]   Resistance training and locomotor recovery after incomplete spinal cord injury: a case series [J].
Gregory, C. M. ;
Bowden, M. G. ;
Jayaraman, A. ;
Shah, P. ;
Behrman, A. ;
Kautz, S. A. ;
Vandenborne, K. .
SPINAL CORD, 2007, 45 (07) :522-530
[7]   Upper and lower extremity robotic devices for rehabilitation and for studying motor control [J].
Hesse, S ;
Schmidt, H ;
Werner, C ;
Bardeleben, A .
CURRENT OPINION IN NEUROLOGY, 2003, 16 (06) :705-710
[8]   Robotic-assisted, body-weight supported treadmill training in individuals following motor incomplete spinal cord injury [J].
Hornby, TG ;
Zemon, DH ;
Campbell, D .
PHYSICAL THERAPY, 2005, 85 (01) :52-66
[9]   Effects of locomotion training with assistance of a robot-driven gait orthosis in hemiparetic patients after stroke -: A randomized controlled pilot study [J].
Husemann, Britta ;
Mueller, Friedemann ;
Krewer, Carmen ;
Heller, Silke ;
Koenig, Eberhardt .
STROKE, 2007, 38 (02) :349-354
[10]   Level walking and ambulatory capacity in persons with incomplete spinal cord injury: relationship with muscle strength [J].
Kim, CM ;
Eng, JJ ;
Whittaker, MW .
SPINAL CORD, 2004, 42 (03) :156-162