A new approach for quantitative analysis of L-phenylalanine using a novel semi-sandwich immunometric assay

被引:4
作者
Kubota, Kazuyuki [2 ]
Mizukoshi, Toshimi [1 ]
Miyano, Hiroshi [1 ]
机构
[1] Ajinomoto Co Inc, Inst Innovat, Kawasaki Ku, Kawasaki, Kanagawa 2108681, Japan
[2] Tokai Plant Ajinomoto Co Inc, Qual Management Dept, Yokaichi, Mie 5100885, Japan
关键词
Semi-sandwich immunometric assay; Amino acids; Phenylalanine; Derivatization; Pre-derivatization; AMINO-ACID LEVELS; TANDEM MASS-SPECTROMETRY; SMALL MOLECULES; ENZYME-IMMUNOASSAY; PLASMA; ELISA; SERUM; ANTIBODY; PHENYLKETONURIA; SPECIFICITY;
D O I
10.1007/s00216-013-7081-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here, we describe a novel method for l-phenylalanine analysis using a sandwich-type immunometric assay approach for use as a new method for amino acid analysis. To overcome difficulties of the preparation of high-affinity and selectivity monoclonal antibodies against l-phenylalanine and the inability to use sandwich-type immunometric assays due to their small molecular weight, three procedures were examined. First, amino groups of l-phenylalanine were modified by "N-Fmoc-l-cysteine" (FC) residues and the derivative (FC-Phe) was used as a hapten. Immunization of mice with bovine serum albumin/FC-Phe conjugate successfully yielded specific monoclonal anti-FC-Phe antibodies. Second, a new derivatization reagent, "biotin linker conjugate of FC-Phe N-succinimidyl ester" (FC(Biotin)-NHS), was synthesized to convert l-phenylalanine to FC-(Biotin)-Phe as a hapten structure. The biotin moiety linked to the thiol group of cysteine formed a second binding site for streptavidin/horseradish peroxidase (HRP) conjugates for optical detection. Third, a new semi-sandwich-type immunometric assay was established using pre-derivatized l-phenylalanine, the monoclonal anti-FC-Phe antibody, and streptavidin/HRP conjugate (without second antibody). Using the new "semi-sandwich" immunometric assay system, a detection limit of 35 nM (60 amol per analysis) and a detection range of 0.1-20 mu M were attained using a standard l-phenylalanine solution. Rat plasma samples were analyzed to test reliability. Intra-day assay precision was within 6 % of the coefficient of variation; inter-day variation was 0.1 %. The recovery rates were from 92.4 to 123.7 %. This is the first report of the quantitative determination of l-phenylalanine using a reliable semi-sandwich immunometric assay approach and will be applicable to the quantitative determination of other amino acids.
引用
收藏
页码:8093 / 8103
页数:11
相关论文
共 42 条
  • [21] Mochizuki Y, 1996, ANN CLIN LAB SCI, V26, P275
  • [22] Serum Amino Acid Levels as a Biomarker for Renal Cell Carcinoma
    Mustafa, Aladdin
    Gupta, Sapna
    Hudes, Gary R.
    Egleston, Brian L.
    Uzzo, Robert G.
    Kruger, Warren D.
    [J]. JOURNAL OF UROLOGY, 2011, 186 (04) : 1206 - 1212
  • [23] Noguchi Y, 2006, AM J CLIN NUTR, V83, p513S
  • [24] Plasma amino acid concentrations in patients with coronary heart disease: A comparison between UK Indian Asian and Caucasian men
    Obeid, OA
    [J]. INTERNATIONAL JOURNAL FOR VITAMIN AND NUTRITION RESEARCH, 2005, 75 (04) : 267 - 273
  • [25] A GC-MS method for determination of amino acid uptake by plants
    Persson, J
    Näsholm, T
    [J]. PHYSIOLOGIA PLANTARUM, 2001, 113 (03) : 352 - 358
  • [26] Toward the Limits of Sandwich Immunoassay of Very Low Molecular Weight Molecules
    Quinton, Julia
    Charruault, Lise
    Nevers, Marie-Claire
    Volland, Herve
    Dognon, Jean-Pierre
    Creminon, Christophe
    Taran, Frederic
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2536 - 2540
  • [27] SELF CH, 1994, CLIN CHEM, V40, P2035
  • [28] Multifunctional and Highly Sensitive Precolumn Reagents for Amino Acids in Liquid Chromatography/Tandem Mass Spectrometry
    Shimbo, Kazutaka
    Yahashi, Akihisa
    Hirayama, Kazuo
    Nakazawa, Masakazu
    Miyano, Hiroshi
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (13) : 5172 - 5179
  • [29] Precolumn derivatization reagents for high-speed analysis of amines and amino acids in biological fluid using liquid chromatography/electrospray ionization tandem mass spectrometry
    Shimbo, Kazutaka
    Oonuki, Takashi
    Yahashi, Akihisa
    Hirayama, Kazuo
    Miyano, Hiroshi
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (10) : 1483 - 1492
  • [30] Fluorescence polarization immunoassays and related methods for simple, high-throughput screening of small molecules
    Smith, David S.
    Eremin, Sergei A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) : 1499 - 1507