A Comparison of Different Methods of Temperature Measurement by Mothers and Physicians in Healthy Newborns

被引:5
作者
Oncel, Mehmet Yekta [1 ]
Tekgunduz, Kadir Serafettin [2 ]
Ozdemir, Ramazan [1 ]
Calisici, Erhan [1 ]
Karahan, Sevilay [3 ]
Erdeve, Omer [1 ]
Oguz, Serife Suna [1 ]
Dilmen, Ugur [1 ]
机构
[1] Zekai Tahir Burak Matern Teaching Hosp, Div Neonatol, TR-06600 Ankara, Turkey
[2] Ataturk Univ, Dept Pediat, Div Neonatol, Fac Med, Erzurum, Turkey
[3] Hacettepe Univ, Dept Biostat, Ankara, Turkey
关键词
Mercury thermometer; Axillary; Rectal; Digital; Infrared; Newborn; CHILDREN; THERMOMETER; AXILLARY; INFANTS; MERCURY; FEVER;
D O I
10.1007/s12098-012-0790-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To compare the accuracy of digital axillary thermometer (DAT), rectal glass mercury thermometer (RGMT) and infrared forehead skin thermometer (IFST) measurements made by mothers and physicians in healthy newborns. The body temperature measurements of 120 healthy newborns were made on their 2nd day of life using DAT, RGMT and IFST, first by mothers followed by a designated physician. Correlation analysis was performed for the measurements obtained by mothers and the physician. The presence of a former child or children at home, the educational level of the mother and maternal age were also recorded. No correlation was observed between the measurements made by mothers and the physician using RGMT (R-2 = 0.096). The temperatures measured by mothers and the physician showed a significant correlation when a DAT and IFST were used (R-2 = 0.923, p < 0.001; R-2 = 0.916, p < 0.001, respectively). Difficulty of use and interpretation make RGMTs less practical than DATs and IFST for use by mothers. Measurements with an IFST are obtained from a newborn's forehead in a shorter length of time compared to DATs, which makes it a more practical option.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [41] Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
    Cultu, Oege
    Yildirim, Inci
    Ceyhan, Mehmet
    Korkmaz, Ayse
    Yurdakoek, Murat
    Karaagaoglu, Ergun
    Secmeer, Guelten
    [J]. TURKISH JOURNAL OF PEDIATRICS, 2008, 50 (04) : 354 - 358
  • [42] Comparison of axillary, tympanic membrane and rectal temperature measurement in cats
    Smith, Victoria A.
    Lamb, Valerie
    McBrearty, Alix R.
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2015, 17 (12) : 1028 - 1034
  • [43] Comparison of temporal artery to mercury and digital temperature measurement in pediatrics
    Isler, Aysegul
    Aydin, Resmiye
    Guven, Serife Tutar
    Gunay, Sema
    [J]. INTERNATIONAL EMERGENCY NURSING, 2014, 22 (03) : 165 - 168
  • [44] Measurement of nasal nitric oxide: evaluation of six different sampling methods
    de Winter-de Groot, K. M.
    van der Ent, C. K.
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2009, 39 (01) : 72 - 77
  • [45] Reliability of the Infrared and Chemical Dot Temperature Measurement Methods in the Children Admitted in the Pediatric Emergency Unit: A Prospective Study
    Acikgoz, Mehmet
    Guzel, Ahmet
    Mura, Naci
    Karli, Arzu
    Sezgin, Ugur
    [J]. KUWAIT MEDICAL JOURNAL, 2016, 48 (02): : 105 - 110
  • [46] Range for Normal Body Temperature in Hemodialysis Patients and Its Comparison with That of Healthy Individuals
    Hasan, Rabia
    Adhi, Mehreen
    Mahmood, Syed Faisal
    Noman, Fatima
    Awan, Safia
    Akhtar, Fazal
    Naqvi, Anwar
    Rizvi, Adeeb ul Hassan
    [J]. NEPHRON CLINICAL PRACTICE, 2010, 114 (04): : C303 - C308
  • [47] Temperature Measurements Comparison of different thermometer types for patients with cancer
    Gates, Deborah
    Horner, Victoria
    Bradley, Lindsey
    Sheperd, Takeya Fogle
    John, Omena
    Higgins, Melinda
    [J]. CLINICAL JOURNAL OF ONCOLOGY NURSING, 2018, 22 (06) : 611 - 617
  • [48] Comparison of refractive error and central corneal thickness in neonates of diabetic and healthy mothers
    Goncu, Tugba
    Cakmak, Alpay
    Akal, Ali
    Cakmak, Sevim
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (05) : 396 - 399
  • [49] Comparison of QT Interval between Neonates with Maternal Gestational Diabetes and Healthy Mothers
    Esmaeili, Hassan
    Koochaki, Maryam
    Besharat, Mahsa
    Sharifnezhad, Farzad
    Alaee, Ehsan
    [J]. IRANIAN JOURNAL OF NEONATOLOGY, 2021, 12 (01) : 66 - 69
  • [50] Evaluating alternative temperature measurement sites in cats within a home environment: A comparison with rectal temperature
    Polat, Dogukan
    Yanmaz, Latif Emrah
    [J]. VETERINARY MEDICINE AND SCIENCE, 2024, 10 (03)