A Comparison of Different Methods of Temperature Measurement by Mothers and Physicians in Healthy Newborns

被引:5
作者
Oncel, Mehmet Yekta [1 ]
Tekgunduz, Kadir Serafettin [2 ]
Ozdemir, Ramazan [1 ]
Calisici, Erhan [1 ]
Karahan, Sevilay [3 ]
Erdeve, Omer [1 ]
Oguz, Serife Suna [1 ]
Dilmen, Ugur [1 ]
机构
[1] Zekai Tahir Burak Matern Teaching Hosp, Div Neonatol, TR-06600 Ankara, Turkey
[2] Ataturk Univ, Dept Pediat, Div Neonatol, Fac Med, Erzurum, Turkey
[3] Hacettepe Univ, Dept Biostat, Ankara, Turkey
关键词
Mercury thermometer; Axillary; Rectal; Digital; Infrared; Newborn; CHILDREN; THERMOMETER; AXILLARY; INFANTS; MERCURY; FEVER;
D O I
10.1007/s12098-012-0790-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To compare the accuracy of digital axillary thermometer (DAT), rectal glass mercury thermometer (RGMT) and infrared forehead skin thermometer (IFST) measurements made by mothers and physicians in healthy newborns. The body temperature measurements of 120 healthy newborns were made on their 2nd day of life using DAT, RGMT and IFST, first by mothers followed by a designated physician. Correlation analysis was performed for the measurements obtained by mothers and the physician. The presence of a former child or children at home, the educational level of the mother and maternal age were also recorded. No correlation was observed between the measurements made by mothers and the physician using RGMT (R-2 = 0.096). The temperatures measured by mothers and the physician showed a significant correlation when a DAT and IFST were used (R-2 = 0.923, p < 0.001; R-2 = 0.916, p < 0.001, respectively). Difficulty of use and interpretation make RGMTs less practical than DATs and IFST for use by mothers. Measurements with an IFST are obtained from a newborn's forehead in a shorter length of time compared to DATs, which makes it a more practical option.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [31] COMPARING THREE METHODS OF INTRAOPERATIVE TEMPERATURE MEASUREMENT IN ADULTS
    Zulkapli, A.
    Tang, S. S. P.
    Lee, C. Y.
    Cheah, S. K.
    Manap, N. Abdul
    ANESTHESIA AND ANALGESIA, 2016, 123 : 775 - 776
  • [32] Comparison of transcutaneous and total serum bilirubin measurement in Turkish newborns
    Simsek, Fatih Mehmet
    Narter, Fatma
    Erguven, Muferet
    TURKISH JOURNAL OF PEDIATRICS, 2014, 56 (06) : 612 - 617
  • [33] Comparison of Blood Lead Concentrations in Mothers of Children with Congenital Heart Disease and Mothers of Healthy Children
    Forod Salehi
    Kimia Darmiani
    Sameneh Nakhaee
    Alireza Amirabadi zadeh
    Seyed Yoosef Javadmoosavi
    Vahideh Faghihi
    Omid Mehrpour
    Biological Trace Element Research, 2022, 200 : 2001 - 2007
  • [34] Comparison of Blood Lead Concentrations in Mothers of Children with Congenital Heart Disease and Mothers of Healthy Children
    Salehi, Forod
    Darmiani, Kimia
    Nakhaee, Sameneh
    Zadeh, Alireza Amirabadi
    Javadmoosavi, Seyed Yoosef
    Faghihi, Vahideh
    Mehrpour, Omid
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2022, 200 (05) : 2001 - 2007
  • [35] Diagnostic accuracy of three different methods of temperature measurement in acutely ill geriatric patients
    Singler, Katrin
    Bertsch, Thomas
    Heppner, Hans Juergen
    Kob, Robert
    Hammer, Klaus
    Biber, Roland
    Sieber, Cornel C.
    Christ, Michael
    AGE AND AGEING, 2013, 42 (06) : 740 - 746
  • [36] The measurement of tibial torsion by magnetic resonance imaging in children: the comparison of three different methods
    Basaran S.H.
    Ercin E.
    Bayrak A.
    Cumen H.
    Bilgili M.G.
    Inci E.
    Avkan M.C.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1327 - 1332
  • [37] Monitoring temperature in children undergoing anaesthesia: a comparison of methods
    Drake-Brockman, T. F. E.
    Hegarty, M.
    Chambers, N. A.
    von Ungern-Sternberg, B. S.
    ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (03) : 315 - 320
  • [38] Measurement of body temperature in adult patients: Comparative study of accuracy, reliability and validity of different devices
    Rubia-Rubia, J.
    Arias, A.
    Sierra, A.
    Aguirre-Jaime, A.
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2011, 48 (07) : 872 - 880
  • [39] Comparison of mothers' perceptions of hunger cues in 3-month-old infant under different feeding methods
    Zhao, Fenghua
    Sun, Yijie
    Zhang, Yue
    Xu, Tao
    Wang, Nianrong
    Yan, Shuangqin
    Zeng, Ting
    Zhang, Fenghua
    Gao, Jie
    Yue, Qing
    Rozelle, Scott
    BMC PUBLIC HEALTH, 2023, 23 (01)
  • [40] Comparison of mothers’ perceptions of hunger cues in 3-month-old infant under different feeding methods
    Fenghua Zhao
    Yijie Sun
    Yue Zhang
    Tao Xu
    Nianrong Wang
    Shuangqin Yan
    Ting Zeng
    Fenghua Zhang
    Jie Gao
    Qing Yue
    Scott Rozelle
    BMC Public Health, 23