Performance of United States Serologic Assays in the Diagnosis of Lyme Borreliosis Acquired in Europe

被引:55
作者
Branda, John A. [1 ]
Strle, Franc [4 ]
Strle, Klemen [3 ]
Sikand, Nikhil [3 ]
Ferraro, Mary Jane [1 ,2 ]
Steere, Allen C. [2 ,3 ]
机构
[1] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Med, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Ctr Immunol & Inflammatory Dis, Div Rheumatol Allergy & Immunol, Boston, MA 02114 USA
[4] Univ Med Ctr Ljubljana, Dept Infect Dis, Ljubljana, Slovenia
关键词
Lyme; Borrelia burgdorferi; VlsE; C6; diagnosis; BURGDORFERI SENSU-LATO; LINKED IMMUNOSORBENT ASSAYS; STANDARDIZED WESTERN BLOTS; VARIABLE SURFACE-ANTIGEN; C6 PEPTIDE ELISA; INTERPRETATION CRITERIA; ANTIBODY-RESPONSE; ERYTHEMA MIGRANS; DISEASE; VLSE;
D O I
10.1093/cid/cit235
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Physicians in the United States sometimes need to evaluate a patient for suspected Lyme borreliosis (LB) who may have acquired the infection in Europe. Using serum samples from European LB patients, we compared the performance of European and US serodiagnostic tests, including newer-generation assays containing Vmp-like sequence, expressed or its C6 peptide. Methods. The sensitivity of each assay was determined using 64 serum samples from LB patients with early or late disease manifestations who acquired the infection in Europe. Specificity was measured using 100 sera from healthy subjects from a nonendemic area. Results. For the detection of European-acquired infection, conventional 2-tiered testing (enzyme-linked immunosorbent assay [ ELISA] followed by immunoblotting) using US assays had an overall sensitivity and specificity of 52% and 100%, compared with 81% (P = .0007) and 99% (P = 1.00) using analogous European tests. The sensitivity of a US C6 ELISA used as a stand-alone test (88% overall) was statistically comparable to that of conventional 2-tiered testing using European tests (P = .47) and was 100% specific. Similarly, an alternative 2-tiered algorithm using a standard US ELISA followed by a C6 ELISA was comparably sensitive (84% overall) compared with conventional 2-tiered testing using European assays (P = .82), and specificity remained 100%. Conclusions. European assays outperformed analogous US assays in a conventional 2-tiered testing algorithm. However, a C6 ELISA used as a stand-alone test or in the second tier of a 2-tiered algorithm performed comparably to conventional 2-tiered testing using European assays, and can be used for evaluation of any patient, regardless of travel history.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 40 条
  • [1] ANTIGENICALLY VARIABLE BORRELIA-BURGDORFERI ISOLATED FROM COTTONTAIL RABBITS AND IXODES-DENTATUS IN RURAL AND URBAN AREAS
    ANDERSON, JF
    MAGNARELLI, LA
    LEFEBVRE, RB
    ANDREADIS, TG
    MCANINCH, JB
    PERNG, GC
    JOHNSON, RC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (01) : 13 - 20
  • [2] [Anonymous], 1995, MMWR MORB MORTAL WKL, V44, P590
  • [3] [Anonymous], QUALITATSSTANDARDS M
  • [4] Serodiagnosis of Lyme disease by kinetic enzyme-linked immunosorbent assay using recombinant VlsE1 or peptide antigens of Borrelia burgdorferi compared with 2-tiered testing using whole-cell lysates
    Bacon, RM
    Biggerstaff, BJ
    Schriefer, ME
    Gilmore, RD
    Philipp, MT
    Steere, AC
    Wormser, GP
    Marques, AR
    Johnson, BJB
    [J]. JOURNAL OF INFECTIOUS DISEASES, 2003, 187 (08) : 1187 - 1199
  • [5] USE OF AN AUTOLOGOUS ANTIGEN IN THE SEROLOGIC TESTING OF PATIENTS WITH ERYTHEMA MIGRANS OF LYME-DISEASE
    BERGER, BW
    MACDONALD, AB
    BENACH, JL
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1988, 18 (06) : 1243 - 1246
  • [6] Two-Tiered Antibody Testing for Lyme Disease With Use of 2 Enzyme Immunoassays, a Whole-Cell Sonicate Enzyme Immunoassay Followed by a VlsE C6 Peptide Enzyme Immunoassay
    Branda, John A.
    Linskey, Katy
    Kim, Yeowon A.
    Steere, Allen C.
    Ferraro, Mary Jane
    [J]. CLINICAL INFECTIOUS DISEASES, 2011, 53 (06) : 541 - 547
  • [7] 2-Tiered Antibody Testing for Early and Late Lyme Disease Using Only an Immunoglobulin G Blot with the Addition of a VlsE Band as the Second-Tier Test
    Branda, John A.
    Aguero-Rosenfeld, Maria E.
    Ferraro, Mary Jane
    Johnson, Barbara J. B.
    Wormser, Gary P.
    Steere, Allen C.
    [J]. CLINICAL INFECTIOUS DISEASES, 2010, 50 (01) : 20 - 26
  • [8] VARIABLE SERUM IMMUNOGLOBULIN RESPONSES AGAINST DIFFERENT BORRELIA-BURGDORFERI SENSU LATE SPECIES IN A POPULATION AT RISK FOR AND PATIENTS WITH LYME-DISEASE
    BUNIKIS, J
    OLSEN, B
    WESTMAN, G
    BERGSTROM, S
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (06) : 1473 - 1478
  • [9] Centers for Disease Control and Prevention (CDC), REP CAS LYM DIS YEAR
  • [10] Subjective Symptoms after Treatment of Early Lyme Disease
    Cerar, Dasa
    Cerar, Tjasa
    Ruzic-Sabljic, Eva
    Wormser, Gary P.
    Strle, Franc
    [J]. AMERICAN JOURNAL OF MEDICINE, 2010, 123 (01) : 79 - 86