Blood flow imaging -: A new real-time, 2-D flow imaging technique

被引:29
|
作者
Lovstakken, L [1 ]
Bjærum, S
Martens, D
Torp, H
机构
[1] NTNU, Dept Circulat & Med Imaging, Trondheim, Norway
[2] GE Vingmed Ultrasound, Horten, Norway
关键词
D O I
10.1109/TUFFC.2006.1593367
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents a new method for the visualization of two-dimensional (2-D) blood flow in ultrasound imaging systems called blood flow imaging (BFI). Conventional methods of color flow imaging (CFI) and power Doppler (PD) techniques are limited as the velocity component transversal to the ultrasound beam cannot be estimated from the received Doppler signal. The BFI relies oil the preservation and display of the speckle pattern originating from the blood flow scatterer signal, and it provides qualitative information of the blood flow distribution and movement in any direction of the image. By displaying speckle pattern images acquired with a high frame rate in slow motion, the blood flow movement can be visually tracked from frame to frame. The BFI is easily combined with conventional CFI and PD methods, and the resulting display modes have been shown to have several advantages compared to CFI or PD methods alone. Two different display modes have been implemented: one combining BFI with conventional CFI, and one combining BFI with PD. Initial clinical trials have been performed to assess the clinical usefulness of BFI. The method especially has potential in vascular imaging, but it also shows potential in other clinical applications.
引用
收藏
页码:289 / 299
页数:11
相关论文
共 50 条
  • [1] Real-time blood motion imaging a 2D blood flow visualization technique
    Loevstakken, L
    Bjaerum, S
    Martens, D
    Torp, H
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 602 - 605
  • [2] Real-Time 2-D Phased Array Vector Flow Imaging
    Holbek, Simon
    Hansen, Kristoffer Lindskov
    Fogh, Nikolaj
    Moshavegh, Ramin
    Olesen, Jacob Bjerring
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) : 1205 - 1213
  • [3] 2-D REAL-TIME FLOW IMAGING OF PROSTHETIC HEART-VALVES
    BOMMER, WJ
    TAM, K
    EHRET, R
    REBECK, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 526 - 526
  • [4] Real-Time 2-D Temperature Imaging Using Ultrasound
    Liu, Dalong
    Ebbini, Emad S.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 12 - 16
  • [5] Blood motion imaging -: A new technique to visualize 2D blood flow
    Bjærum, S
    Martens, D
    Kristoffersen, K
    Torp, H
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1507 - 1510
  • [6] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTOCORRELATION TECHNIQUE
    KASAI, C
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 94 - 94
  • [7] ASSESSMENT OF MYOCARDIAL BLOOD-FLOW BY REAL-TIME INFRARED IMAGING
    ADACHI, H
    BECKER, LC
    AMBROSIO, G
    TAKEDA, K
    DIPAULA, AF
    BAUMGARTNER, WA
    BORKON, AM
    REITZ, BA
    JOURNAL OF SURGICAL RESEARCH, 1987, 43 (01) : 94 - 102
  • [8] The flow design of real-time ISAR imaging
    Li Shi-guo
    Li Chong-yi
    2007 1ST ASIAN AND PACIFIC CONFERENCE ON SYNTHETIC APERTURE RADAR PROCEEDINGS, 2007, : 811 - 814
  • [9] STUDY OF LEFT-VENTRICULAR FLOW DYNAMICS IN DILATED CARDIOMYOPATHY BY REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING-SYSTEM (2-D DOPPLER)
    KUDO, T
    SAKURAI, N
    MIKAMI, T
    AKUTSU, M
    SAKAMOTO, S
    YASUDA, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (03): : 299 - 299
  • [10] Optimization of real-time high frequency ultrasound for blood flow imaging in the microcirculation
    Kruse, D
    Silverman, R
    Erickson, S
    Coleman, DJ
    Ferrara, K
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1461 - 1464