Evaluation of an integrated graphical display to promote acute change detection in ICU patients

被引:40
作者
Anders, Shilo [1 ,2 ,3 ]
Albert, Robert [8 ]
Miller, Anne [1 ,2 ,4 ]
Weinger, Matthew B. [1 ,2 ,3 ,7 ]
Doig, Alexa K. [6 ]
Behrens, Michael [5 ]
Agutter, Jim [5 ,8 ]
机构
[1] Vanderbilt Univ, Sch Med, Ctr Res & Innovat Syst Safety, Nashville, TN 37212 USA
[2] Vanderbilt Univ, Sch Med, Dept Anesthesiol, Nashville, TN 37212 USA
[3] Vanderbilt Univ, Sch Med, Dept Biomed Informat, Nashville, TN 37212 USA
[4] Vanderbilt Univ, Sch Med, Sch Nursing, Nashville, TN 37212 USA
[5] Univ Utah, Dept Anesthesiol, Salt Lake City, UT USA
[6] Univ Utah, Coll Nursing, Salt Lake City, UT 84112 USA
[7] Vet Affairs Tennessee Valley Healthcare Syst, Geriatr Res Educ & Clin Ctr, Nashville, TN USA
[8] Medvis LLC, Salt Lake City, UT USA
关键词
Medical informatics; Human engineering; Man-machine systems; Intensive care; CARDIOVASCULAR DISPLAY; SYSTEM; PERFORMANCE; SIMULATOR;
D O I
10.1016/j.ijmedinf.2012.04.004
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: The purpose of this study was to evaluate ICU nurses' ability to detect patient change using an integrated graphical information display (IGID) versus a conventional tabular ICU patient information display (i.e. electronic chart). Design: Using participants from two different sites, we conducted a repeated measures simulator-based experiment to assess ICU nurses' ability to detect abnormal patient variables using a novel IGID versus a conventional tabular information display. Patient scenarios and display presentations were fully counterbalanced. Measurements: We measured percent correct detection of abnormal patient variables, nurses' perceived workload (NASA-TLX), and display usability ratings. Results: 32 ICU nurses (87% female, median age of 29 years, and median ICU experience of 2.5 years) using the IGID detected more abnormal variables compared to the tabular display [F(1, 119) = 13.0, p < 0.05]. There was a significant main effect of site [F(1, 119) = 14.2], with development site participants doing better. There were no significant differences in nurses' perceived workload. The IGID display was rated as more usable than the conventional display [F(1, 60) = 31.7]. Conclusion: Overall, nurses reported more important physiological information with the novel IGID than tabular display. Moreover, the finding of site differences may reflect local influences in work practice and involvement in iterative display design methodology. Information displays developed using user-centered design should accommodate the full diversity of the intended user population across use sites. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:842 / 851
页数:10
相关论文
共 22 条
[1]   Evaluation of graphic cardiovascular display in a high-fidelity simulator [J].
Agutter, J ;
Drews, F ;
Syroid, N ;
Westneskow, D ;
Albert, R ;
Strayer, D ;
Bermudez, J ;
Weinger, MB .
ANESTHESIA AND ANALGESIA, 2003, 97 (05) :1403-1413
[2]   A simulation-based evaluation of a graphic cardiovascular display [J].
Albert, Robert W. ;
Agutter, James A. ;
Syroid, Noah D. ;
Johnson, Ken B. ;
Loeb, Robert G. ;
Westenskow, Dwayne R. .
ANESTHESIA AND ANALGESIA, 2007, 105 (05) :1303-1311
[3]  
[Anonymous], 2001, Statistical Methods for Psychology
[4]  
[Anonymous], ADV PSYCHOL, DOI DOI 10.1016/S0166-4115(08)62386-9
[5]   Some unintended consequences of information technology in health care: The nature of patient care information system-related errors [J].
Ash, JS ;
Berg, M ;
Coiera, E .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2004, 11 (02) :104-112
[6]   A graphical object display improves anesthesiologists' performance on a simulated diagnostic task [J].
Blike, GT ;
Surgenor, SD ;
Whalen, K .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (01) :37-44
[7]   Comparison of four different display designs of a novel anaesthetic monitoring system, the 'integrated monitor of anaesthesia (IMA™)' [J].
Charabati, S. ;
Bracco, D. ;
Mathieu, P. A. ;
Hemmerling, T. M. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) :670-677
[8]  
Christensen C.M., 2009, INNOVATORS PRESCRIPT
[9]  
Clason D.L., 1994, Journal of Agricultural Education, V35, P4, DOI [10.5032/jae.1994.04031, DOI 10.5032/JAE.1994.04031]
[10]  
Clayton J.M., 1997, ED PSYCHOL, V17, P373, DOI [DOI 10.1080/0144341970170401, 10.1080/0144341970170401]