Visual Acuity During Direct Laryngoscopy at Different Illuminance Levels

被引:8
作者
Baker, Paul A. [1 ]
Raos, Amy S. [1 ]
Thompson, John M. D. [2 ]
Jacobs, Robert J. [3 ]
机构
[1] Starship Childrens Hlth, Dept Paediat Anaesthesia, Auckland, New Zealand
[2] Univ Auckland, Dept Paediat, Auckland 1142, New Zealand
[3] Univ Auckland, Dept Optometry & Vis Sci, New Zealand Natl Eye Ctr, Auckland 1142, New Zealand
关键词
LIGHT-INTENSITY; DIFFICULT INTUBATION; BLADES; ANESTHESIA; MANNEQUIN; MINIMUM; VISION; AIRWAY;
D O I
10.1213/ANE.0b013e318273f397
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Adequate light is essential for vision during direct laryngoscopy. The ISO 7376:2009 standard specifies the minimal illuminance for laryngoscopes. No studies have objectively examined the relationship between laryngoscope illumination and visual acuity during laryngoscopy. METHODS: We measured the near visual performance of 50 anesthesiologists during direct laryngoscopy using near vision charts located at the larynx of 4 manikins. A variable voltage supply adjusted the illuminance from the laryngoscope to 50 lux, 200 lux, 700 lux, and 2000 lux. Participants also rated their experience regarding brightness of the laryngoscope, clarity of view, visual performance, and suitability and adequacy of the light, before proceeding to the next manikin with a different light level. The distance visual performance of the participants was also measured using standard letter acuity wall charts at the same light levels. RESULTS: Visual acuity in manikins and on wall charts was associated with an increasing lux level (P < 0.0001). Visual acuity was lower at 50 lux and 200 lux compared with 700 lux by significantly more than the clinically discernible 0.1 logMAR. No statistically significant improvement in visual acuity occurred when illuminance was increased to 2000 lux. The mean (standard deviation) logMAR scores at the 4 chosen lux levels on the manikin charts were: 50 lux 0.05 (0.13), 200 lux 0.06 (0.10), 700 lux -0.05 (0.11), and 2000 lux -0.07 (0.11). This result was unaffected by age, seniority, subspecialty, history of difficulty focusing, or use of lenses for laryngoscopy. Subjective rating of laryngoscope brightness favored 2000 lux for clarity of view, suitability of the light for laryngoscopy, and visual performance. The average observation distance for direct laryngoscopy was 32 cm. CONCLUSIONS: Visual acuity improves as the laryngoscope illuminance increases up to 700 lux. No statistically significant improvement was measured by increasing the illuminance up to 2000 lux. Subjectively, anesthesiologists favor illuminance of 2000 lux for direct laryngoscopy. (Anesth Analg 2013;116:343-50)
引用
收藏
页码:343 / 350
页数:8
相关论文
共 23 条
  • [1] [Anonymous], 1922, BRONCHOSCOPY ESOPHAG
  • [2] BAILEY IL, 1991, INVEST OPHTH VIS SCI, V32, P422
  • [3] Equipment to manage a difficult airway during anaesthesia
    Baker, P. A.
    Flanagan, B. T.
    Greenland, K. B.
    Morris, R.
    Owen, H.
    Riley, R. H.
    Runciman, W. B.
    Scott, D. A.
    Segal, R.
    Smithies, W. J.
    Merry, A. F.
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (01) : 16 - 34
  • [4] An audit of laryngoscopes and application of a new ISO standard
    Baker, Paul A.
    McQuoid, Shane
    Thompson, John M. D.
    Jacobs, Robert J.
    [J]. PEDIATRIC ANESTHESIA, 2011, 21 (04) : 428 - 434
  • [5] The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes
    Bucx, MJL
    de Gast, HM
    Veldhuis, J
    Hassing, LH
    Meulemans, A
    Kammeyer, A
    [J]. ANAESTHESIA, 2003, 58 (05) : 461 - 465
  • [6] A new practical classification of laryngeal view
    Cook, TM
    [J]. ANAESTHESIA, 2000, 55 (03) : 274 - 279
  • [7] An assessment of the luminance and light field characteristics of used direct laryngoscopes
    Crosby, E
    Cleland, M
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (08): : 792 - 796
  • [8] Elliott DB., 2007, Clinical Procedures in Primary Eye Care, DOI DOI 10.1016/B978-0-7506-8896-3.50010-9
  • [9] Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    Henderson, JJ
    Popat, MT
    Latto, IP
    Pearce, AC
    [J]. ANAESTHESIA, 2004, 59 (07) : 675 - 694
  • [10] The reliability of laryngoscope lights
    Howes, BW
    [J]. ANAESTHESIA, 2006, 61 (05) : 488 - 491