The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector

被引:151
作者
Gundacker, Stefan [1 ,2 ]
Heering, Arjan [3 ]
机构
[1] UniMIB, Piazza Ateneo Nuovo 1, I-20126 Milan, Italy
[2] CERN, Esplanade Particules 1, CH-1211 Meyrin, Switzerland
[3] Univ Notre Dame, Notre Dame, IN 46556 USA
关键词
SiPM; SPAD; Geiger mode avalanche; timing; TOF-PET; HEP; solid state photon detector; TIME-OF-FLIGHT; POSITRON-EMISSION-TOMOGRAPHY; TIMING RESOLUTION; AVALANCHE PHOTODIODES; DETECTION EFFICIENCY; PET/MRI INSERT; DIGITAL SIPM; HV CMOS; PET; SCINTILLATOR;
D O I
10.1088/1361-6560/ab7b2d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The silicon photomultiplier (SiPM) is an established device of choice for a variety of applications, e.g. in time of flight positron emission tomography (TOF-PET), lifetime fluorescence spectroscopy, distance measurements in LIDAR applications, astrophysics, quantum-cryptography and related applications as well as in high energy physics (HEP). To fully utilize the exceptional performances of the SiPM, in particular its sensitivity down to single photon detection, the dynamic range and its intrinsically fast timing properties, a qualitative description and understanding of the main SiPM parameters and properties is necessary. These analyses consider the structure and the electrical model of a single photon avalanche diode (SPAD) and the integration in an array of SPADs, i.e. the SiPM. The discussion will include the front-end readout and the comparison between analog-SiPMs, where the array of SPADs is connected in parallel, and the digital SiPM, where each SPAD is read out and digitized by its own electronic channel. For several applications a further complete phenomenological view on SiPMs is necessary, defining several SiPM intrinsic parameters, i.e. gain fluctuation, afterpulsing, excess noise, dark count rate, prompt and delayed optical crosstalk, single photon time resolution (SPTR), photon detection effieciency (PDE) etc. These qualities of SiPMs influence directly and indirectly the time and energy resolution, for example in PET and HEP. This complete overview of all parameters allows one to draw solid conclusions on how best performances can be achieved for the various needs of the different applications.
引用
收藏
页数:30
相关论文
共 156 条
  • [81] A prototype MR insertable brain PET using tileable GAPD arrays
    Hong, Key Jo
    Choi, Yong
    Jung, Jin Ho
    Kang, Jihoon
    Hu, Wei
    Lim, Hyun Keong
    Huh, Yoonsuk
    Kim, Sangsu
    Jung, Ji Woong
    Kim, Kyu Bom
    Song, Myung Sung
    Park, Hyun-wook
    [J]. MEDICAL PHYSICS, 2013, 40 (04)
  • [82] Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System
    Hsu, David F. C.
    Ilan, Ezgi
    Peterson, William T.
    Uribe, Jorge
    Lubberink, Mark
    Levin, Craig S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (09) : 1511 - 1518
  • [83] Avalanche Current Measurements in SPADs by Means of Hot-Carrier Luminescence
    Ingargiola, Antonino
    Assanelli, Mattia
    Rech, Ivan
    Gulinatti, Angelo
    Ghioni, Massimo
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2011, 23 (18) : 1319 - 1321
  • [84] Measurement of photon correlations with multipixel photon counters [Invited]
    Kalashnikov, Dmitry
    Krivitsky, Leonid
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2014, 31 (10) : B25 - B33
  • [85] Modeling and fabrication of Geiger mode avalanche photodiodes
    Kindt, WJ
    van Zeijl, HW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 715 - 719
  • [87] Study of TOF PET using Cherenkov light
    Korpar, S.
    Dolenec, R.
    Krizan, P.
    Pestotnik, R.
    Stanovnik, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 654 (01) : 532 - 538
  • [88] Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction
    Kratochwil, Nicolaus
    Gundacker, Stefan
    Lecoq, Paul
    Auffray, Etiennette
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (11)
  • [89] Bismuth germanate coupled to near ultraviolet silicon photomultipliers for time-of-flight PET
    Kwon, Sun Il
    Gola, Alberto
    Ferri, Alessandro
    Piemonte, Claudio
    Cherry, Simon R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18) : L38 - L47
  • [90] ON THE BREMSSTRAHLUNG ORIGIN OF HOT-CARRIER-INDUCED PHOTONS IN SILICON DEVICES
    LACAITA, AL
    ZAPPA, F
    BIGLIARDI, S
    MANFREDI, M
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (03) : 577 - 582