Highly k-t-Space-Accelerated Phase-Contrast MRI

被引:73
作者
Jung, Bernd [1 ]
Honal, Matthias [1 ]
Ullmann, Peter [1 ]
Hennig, Juergen [1 ]
Markl, Michael [1 ]
机构
[1] Univ Hosp, Dept Diagnost Radiol, Freiburg, Germany
关键词
parallel MRI; GRAPPA; dynamic imaging; phase contrast; flow;
D O I
10.1002/mrm.21764
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to combine a recently introduced spatiotemporal parallel imaging technique, PEAK-GRAPPA (parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisition), with two-dimensional (213) cine phase-contrast velocity mapping. Phase-contrast MRI was applied to measure the blood flow in the thoracic aorta and the myocardial motion of the left ventricle. To evaluate the performance of different reconstruction methods, fully acquired k-space data sets were used to compare conventional parallel imaging using GRAPPA with reduction factors of R = 2-6 and PEAK-GRAPPA as well as sliding window reconstruction with reduction factors R = 2-12 (net acceleration factors up to 5.2). PEAK-GRAPPA reconstruction resulted in improved image quality with considerably reduced artifacts, which was also supported by error analysis. To analyze potential blurring or low-pass filtering effects of spatiotemporal PEAK-GRAPPA, the velocity time courses of aortic flow and myocardial tissue motion were evaluated and compared with conventional image reconstructions. Quantitative comparisons of blood flow velocities and pixel-wise correlation analysis of velocities highlight the potential of PEAK-GRAPPA for highly accelerated dynamic phase-contrast velocity mapping. Magn Reson Med 60: 1169-1177, 2008. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:1169 / 1177
页数:9
相关论文
共 20 条
[1]   Accelerating cine phase-contrast flow measurements using k-t BLAST and k-t SENSE [J].
Baltes, C ;
Kozerke, S ;
Hansen, MS ;
Pruessmann, KP ;
Tsao, J ;
Boesiger, P .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1430-1438
[2]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[3]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[4]   Analysis of myocardial motion based on velocity measurements with a black blood prepared segmented gradient-echo sequence: Methodology and applications to normal volunteers and patients [J].
Hennig, J ;
Schneider, B ;
Peschl, S ;
Markl, M ;
Krause, T ;
Laubenberger, J .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :868-877
[5]   k-t GRAPPA:: A k-space implementation for dynamic MRI with high reduction factor [J].
Huang, F ;
Akao, J ;
Vijayakumar, S ;
Duensing, GR ;
Limkeman, M .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1172-1184
[6]  
JUNG B, J MAGN RESO IN PRESS
[7]   Detailed analysis of myocardial motion in or volunteers and patients using high-temporal-resolution MR tissue phase mapping [J].
Jung, Bernd ;
Foell, Daniela ;
Boettler, Petra ;
Petersen, Steffen ;
Hennig, Jurgen ;
Markl, Michael .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1033-1039
[8]  
LEW C, 2007, P 15 ANN M ISMRM BER, P254
[9]   Time-resolved 3-dimensional velocity mapping in the thoracic aorta - Visualization of 3-directional blood flow patterns in healthy volunteers and patients [J].
Markl, M ;
Draney, MT ;
Hope, MD ;
Levin, JM ;
Chan, FP ;
Alley, MT ;
Pelc, NJ ;
Herfkens, RJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) :459-468
[10]   Time-resolved three-dimensional phase-contrast MRI [J].
Markl, M ;
Chan, FP ;
Alley, MT ;
Wedding, KL ;
Draney, MT ;
Elkins, CJ ;
Parker, DW ;
Wicker, R ;
Taylor, CA ;
Herfkens, RJ ;
Pelc, NJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (04) :499-506