Thermal parameters estimation by heating and cooling and thermographic measurement

被引:6
作者
Bison, PG [1 ]
Muscio, A [1 ]
Grinzato, E [1 ]
机构
[1] Ist Tecn Freddo, Consiglio Nazl Ric, I-35127 Padua, Italy
来源
THERMOSENSE XXI | 1999年 / 3700卷
关键词
thermography; diffusivity measurement; Peltier device;
D O I
10.1117/12.342308
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The use of a Peltier device in thermal contact with a specimen can provide heat source and sink. The utilization of this equipment is experimented, applying successive heating and cooling stages on various specimens and measuring the temperature outside of the contact area, Oscillating temperature in time and space can provide indication on the thermal diffusivity. The appealing ability of sourcing and sinking heat, with average null effect on temperature, may represent an innovative approach with respect to traditional stimulation technique. A simple analytical model is exploited fur recovering the inversion equations. Numerical simulation allows to better understand the real process on the sample.