The Fate of Nontargeted Endocardial Leads during the Extraction of One or More Targeted Leads in Pediatrics and Congenital Heart Disease

被引:14
作者
McCanta, Anthony C. [1 ]
Tanel, Ronn E. [2 ]
Gralla, Jane [1 ,3 ]
Runciman, David Martin [1 ]
Collins, Kathryn K. [1 ]
机构
[1] Univ Colorado Denver Sch Med, Childrens Hosp Colorado, Dept Pediat, Aurora, CO 80045 USA
[2] Univ Calif San Francisco, Dept Pediat, UCSF Benioff Childrens Hosp, San Francisco, CA USA
[3] Univ Colorado Denver Sch Publ Hlth, Dept Biostat & Informat, Aurora, CO USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2014年 / 37卷 / 01期
关键词
lead extraction; pediatrics; congenital heart disease; YOUNG-ADULTS; CHILDREN; PERFORMANCE; MANAGEMENT; SHEATH;
D O I
10.1111/pace.12282
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionExtraction of targeted endocardial leads can lead to inadvertent damage or dislodgement of nontargeted leads, though the frequency of this has not been reported in pediatrics and congenital heart disease (CHD). MethodsThis is a retrospective review of lead extraction procedures from 2002 to 2010 from two pediatric and CHD centers evaluating unplanned interventions on nontargeted leads during the extraction of one or more targeted leads. ResultsNontargeted leads were present in the 22 lead extraction procedures performed on 20 patients with median age 15 years (interquartile range, 11.5-18.5 years): 11 (55%) with structurally normal hearts and nine (45%) with CHD. Twenty of 23 targeted leads (86%) were extracted with complete success. Of the 22 nontargeted leads, including 17 atrial leads and five ventricular leads, seven (32%) required further intervention including: five extracted due to damage, dislodgement, or change in device location; one abandoned due to damage; and one dislodged requiring a second procedure for repositioning. The remaining 15 nontargeted leads (68%) were unharmed. Nontargeted leads requiring further intervention had a shorter lead duration in situ (median 2 years, interquartile range 0.5-3.5 years) than unharmed nontargeted leads (median 6.6 years, interquartile range 4.1-9.1 years; P= 0.01). Age at extraction, CHD, implantable cardioverter defibrillator leads, atrial lead position, or primary extraction modality did not predict further intervention for nontargeted leads. Major complications occurred in one procedure (4.5%) with no deaths. ConclusionsIn pediatrics and CHD, nontargeted leads are frequently damaged or dislodged during the extraction of targeted leads. The risk of lead damage or dislodgement has implications for procedural planning and counseling for patients and families of pediatric and CHD patients requiring lead extraction.
引用
收藏
页码:104 / 108
页数:5
相关论文
共 14 条
[1]   Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study [J].
Atallah, Joseph ;
Erickson, Christopher C. ;
Cecchin, Frank ;
Dubin, Anne M. ;
Law, Ian H. ;
Cohen, Mitchell I. ;
LaPage, Martin J. ;
Cannon, Bryan C. ;
Chun, Terrence U. H. ;
Freedenberg, Vicki ;
Gierdalski, Marcin ;
Berul, Charles I. .
CIRCULATION, 2013, 127 (24) :2393-2402
[2]   Lead Extraction in Pediatric and Congenital Heart Disease Patients [J].
Cecchin, Frank ;
Atallah, Joseph ;
Walsh, Edward P. ;
Triedman, John K. ;
Alexander, Mark E. ;
Berul, Charles I. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (05) :437-444
[3]   Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management [J].
Cooper, JM ;
Stephenson, EA ;
Berul, CI ;
Walsh, EP ;
Epstein, LM .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) :344-349
[4]   Transvenous Extraction Performance of Expanded Polytetrafluoroethylene Covered ICD Leads in Comparison to Traditional ICD Leads in Humans [J].
Di Cori, Andrea ;
Bongiorni, Maria Grazia ;
Zucchelli, Giulio ;
Segreti, Luca ;
Viani, Stefano ;
Paperini, Luca ;
Soldati, Ezio .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (11) :1376-1381
[5]   Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease [J].
Fortescue, EB ;
Berul, CI ;
Cecchin, F ;
Walsh, EP ;
Triedman, JK ;
Alexander, ME .
HEART RHYTHM, 2004, 1 (02) :150-159
[6]   Effectiveness of implantable cardioverter-defibrillator lead coil treatments in facilitating ease of extraction [J].
Hackler, Joseph W. ;
Sun, Zhiyuan ;
Lindsay, Bruce D. ;
Wilkoff, Bruce L. ;
Niebauer, Mark J. ;
Tchou, Patrick J. ;
Chung, Mina K. .
HEART RHYTHM, 2010, 7 (07) :890-897
[7]   Initial experience with the Evolution mechanical dilator sheath for lead extraction: Safety and efficacy [J].
Hussein, Ayman A. ;
Wilkoff, Bruce L. ;
Martin, David O. ;
Karim, Saima ;
Kanj, Mohamed ;
Callahan, Thomas ;
Baranowski, Bryan ;
Saliba, Walid I. ;
Wazni, Oussama M. .
HEART RHYTHM, 2010, 7 (07) :870-873
[8]   Laser lead extraction in adult congenital heart disease [J].
Khairy, Paul ;
Roux, Jean-Francois ;
Dubuc, Marc ;
Thibault, Bernard ;
Guerra, Peter G. ;
Macle, Laurent ;
Mercier, Lise-Andree ;
Dore, Annie ;
Roy, Denis ;
Talajic, Mario ;
Page, Pierre .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (05) :507-511
[9]   Laser Lead Extraction in Congenital Heart Disease: A Case-Controlled Study [J].
McCanta, Anthony C. ;
Kong, Melissa H. ;
Carboni, Michael P. ;
Greenfield, Ruth A. ;
Hranitzky, Patrick M. ;
Kanter, Ronald J. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (03) :372-380
[10]   Pediatric and Adult Congenital Endocardial Lead Extraction or Abandonment Decision (PACELEAD) Survey of Lead Management [J].
McCanta, Anthony C. ;
Schaffer, Michael S. ;
Collins, Kathryn K. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (12) :1621-1627