Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery

被引:59
作者
Chen, Xiaoyun [1 ]
Gu, Xiaoxun [1 ]
Wang, Wei [1 ]
Xiao, Wei [1 ]
Jin, Guangming [1 ]
Wang, Lanhua [1 ]
Dai, Ye [1 ]
Zhang, Enen [1 ]
Ruan, Xiaoting [1 ]
Liu, Zhenzhen [1 ]
Luo, Lixia [1 ]
Liu, Yizhi [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
CAPSULAR BAG PERFORMANCE; ROTATIONAL STABILITY; ABERRATION; POSITION; 1-PIECE; SIZE;
D O I
10.1097/j.jcrs.0000000000000219
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the characteristics and factors associated with intraocular lens (IOL) bit and decentration after uneventful phacoemulsification with IOL implantation. Setting: Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Cross-sectional study. Methods: All patients underwent a general ophthalmologic examination and anterior segment photography. IOL tilt and decentration were measured with a second-generation anterior segment optical coherence tomography (Casia2). Univariate and multivariate regression analyses were performed to assess the association between IOL bit and decentration with ocular biometric and systemic parameters, and the visual acuity. Results: A total of 196 eyes of 196 patients were enrolled in this study. IOLs showed a mean tilt of 4.8 degrees toward the inferotemporal direction, and the mean decentration was 0.21 mm. Both eyes presented a mirror symmetry relationship. Twenty-two eyes (11.22%) had a tilt greater than 7 degrees, and 21 eyes (10.72%) had a decentration more than 0.4 mm. Multivariate regression analysis showed previous pars plane vitrectomy (PPV) and short axial length (AL) were associated with greater IOL tilt (P = .014 and P < .001). In addition, long AL, thicker lens, and less capsulorhexis-OL overlap were positively correlated with decentration (P < .001, P = .029, and P = .026). Corrected cstanoe visual acuity did not directly correlate with IOL tilt and decentration (P = .417 and P = .550). Conclusions: PPV history and short AL were associated with greater IOL tilt, whereas longer AL, thicker lens, and overlarge capsulorhexis contribute to greater decentration. Implantation of toric and multifocal IOLs in these patients should be cautious. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1126 / 1131
页数:6
相关论文
共 26 条
  • [1] Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic Intraocular lenses with 6-mm optics in an intraindividual comparison
    Baumeister, M
    Neidhardt, B
    Strobel, J
    Kohnen, T
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (06) : 1051 - 1058
  • [2] Assessment of long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery
    Burgmueller, Michael
    Mihaltz, Kata
    Schuetze, Christopher
    Angermann, Bernhard
    Vecsei-Marlovits, Veronika
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 256 (12) : 2361 - 2367
  • [3] Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging - Validation study
    de Castro, Alberto
    Rosales, Patricia
    Marcos, Susana
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) : 418 - 429
  • [4] Effect of manual capsulorhexis size and position on intraocular lens tilt, centration, and axial position
    Findl, Oliver
    Hirnschall, Nino
    Draschl, Petra
    Wiesinger, Joerg
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07) : 902 - 908
  • [5] Capsular bag performance of a hydrophobic acrylic 1-piece intraocular lens
    Findl, Oliver
    Hirnschall, Nino
    Nishi, Yutaro
    Maurino, Vincenzo
    Crnej, Alia
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) : 90 - 97
  • [6] Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye
    Fujikado, Takashi
    Saika, Makoto
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 2415 - 2423
  • [7] Posterior capsule opacification and capsular bag performance of a microincision intraocular lens
    Gangwani, Vinod
    Hirnschall, Nino
    Koshy, John
    Crnej, Alja
    Nishi, Yutaro
    Maurino, Vincenzo
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 1988 - 1992
  • [8] GUYTON DL, 1990, OPHTHALMOLOGY, V97, P1259
  • [9] Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography
    Hirnschall, Nino
    Buehren, Tobias
    Bajramovic, Ferid
    Trost, Michael
    Teuber, Tanja
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) : 732 - 736
  • [10] Holladay JT, 2002, J REFRACT SURG, V18, P683