In vivo evaluation of occlusalcontact area and maximum bite force in patients with various types of implant-supported prostheses

被引:17
作者
Baca, Emrah [1 ]
Yengin, Esengn [1 ]
Gokcen-Rohlig, Bilge [1 ]
Sato, Suichi [2 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, TR-34390 Istanbul, Turkey
[2] Tohoku Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Sendai, Miyagi 980, Japan
关键词
bite force; implant; prosthesis; CONTACT AREA;
D O I
10.3109/00016357.2012.757360
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To determine the effects of various implant retained and/or supported prostheses on number of occlusal contacts (NOC), occlusal contact area (OCA) and maximum bite force (BF). Patients and methods: In total, 56 patients were included in the study; five test groups and two control groups. The patients in the treatment groups received implant-supported/retained prosthesis; over-dentures retained with two individual attachments in occlusion with complete denture, with four individual attachments in occlusion with complete denture, with four individual attachments in occlusion with fixed partial dentures or natural dentition, 6-implant retained fixed bridges in occlusion with natural dentition and 8-implant retained fixed bridges in occlusion with natural dentition. The patients in control group 1 were wearing conventional complete maxillary and mandibular dentures, whereas in control group 2 they had fixed full-arch porcelain-fused to metal restorations prostheses for both arches. Dental Pre-scale was used measure the NOC, BF and OCA. Results. There was no statistically significant difference between the treatment and control groups, among the groups with regards to NOC. OCA demonstrated different results among the removable and fixed reconstruction groups. With regards to BF, removable dentures supported with four implants showed higher bite force values than controls and two implant over-dentures. Also, a fixed reconstruction using eight implants showed higher BF values than a fixed reconstruction using six implants. Conclusion. Use of implants for removable dentures and fixed reconstructions improve occlusal contact area and bite force.
引用
收藏
页码:1181 / 1187
页数:7
相关论文
共 29 条
  • [1] Food selection and perceptions of chewing ability following provision of implant and conventional prostheses in complete denture wearers
    Allen, F
    McMillan, A
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 320 - 326
  • [2] A novel approach to bite force measurements in a porcine model in vivo
    Bousdras, V. A.
    Cunningham, J. L.
    Ferguson-Pell, M.
    Bamber, M. A.
    Sindet-Pedersen, S.
    Blunn, G.
    Goodship, A. E.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (07) : 663 - 667
  • [3] Brunski J B, 1988, Int J Oral Maxillofac Implants, V3, P85
  • [4] Feine J S, 2002, Gerodontology, V19, P3
  • [5] An overview of complete artificial fixed dentition supported by endosseous implants
    Flanagan, D
    [J]. ARTIFICIAL ORGANS, 2005, 29 (01) : 73 - 81
  • [6] Fontijn-Tekamp FA, 1998, J DENT RES, V77, P1832
  • [7] Hadjieva H, 2005, J INT MED ASS BULGAR, V2, P50
  • [8] BITE FORCE AND STATE OF DENTITION
    HELKIMO, E
    CARLSSON, GE
    HELKIMO, M
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1977, 35 (06) : 297 - 303
  • [9] Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure
    Hidaka, O
    Iwasaki, M
    Saito, M
    Morimoto, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1999, 78 (07) : 1336 - 1344
  • [10] Hotta Patrícia Tiemy Hirono, 2008, Braz. Dent. J., V19, P354