Midline or long peripheral catheters in difficult venous access conditions? A comparative study in patients with acute cardiovascular diseases

被引:13
|
作者
Fabiani, Adam [1 ]
Eletto, Valentina [1 ]
Dreas, Lorella [1 ]
Beltrame, Daria [1 ]
Sanson, Gianfranco [2 ]
机构
[1] Azienda Sanitaria Univ Integrata, Cardiothorac Vasc Dept, Str Fiume 447, Trieste, Italy
[2] Univ Trieste, Dept Med Surg & Hlth Sci, Str Fiume 447, I-34148 Trieste, Italy
关键词
Catheter-related thrombosis; Catheter-related blood stream infection; Complication; Catheter survival; Incidence; Indwelling time; BLOOD-STREAM INFECTION; COMPLICATION RATES; RISK-FACTORS; POLYURETHANE; GUIDELINES; SILICONE; THROMBOSIS; DEVICES; PICC;
D O I
10.1016/j.ajic.2019.12.025
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Midline catheters (MCs) are commonly inserted in patients with difficult venous access (DVA) needing peripheral access. Recently, the alternative placement of ultrasound-guided long peripheral catheters (LPCs) has spread. However, no study has compared the reliability of the 2 devices. This study aims to compare the safety and reliability of MCs and LPCs in DVA patients. Methods: A retrospective cohort study was conducted, enrolling 184 DVA patients. Polyurethane MCs and 2 lengths of polyethylene LPCs (8/10 cm and 18 cm) were compared. The independent effect of catheter type on uncomplicated catheter survival was determined through a Cox regression analysis. Results: The relative incidences of overall catheter-related complications (CRCs) were 15.84 of 1,000, 10.64 of 1,000, and 6.27 of 1,000 catheter-days for 8/10 cm-LPCs, 18 cm-LPCs, and MCs, respectively. The relative incidences of catheter-related bloodstream infections were 0.72 of 1,000 for both length LPCs and 0.48 of 1,000 catheter-days for MCs. Compared to MCs, a significant increase in CRC risk for 8/10 cm LPCs (hazard ratio [HR] 5.328; 95% confidence interval [CI] 2.118-13.404; P < 0.001) was found, along with a nonsignificant trend toward an increased risk for 18 cm-LCPs (HR 2.489; 95% CI 0.961-6.448; P= 0.060). Conclusion: MCs allow for longer uncomplicated indwelling times than LPCs. The decision regarding which catheter to use should consider the planned duration of intravenous therapy, the patient's clinical condition, and the cost of the device. (C) 2020 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1158 / 1165
页数:8
相关论文
共 37 条
  • [1] Ultrasound-Guided Peripheral Intravenous Catheter Insertion Training Reduces Use of Midline Catheters in Hospitalized Patients With Difficult Intravenous Access
    Amick, Ashley E.
    Feinsmith, Sarah E.
    Sell, Jordan
    Davis, Evan M.
    Wayne, Diane B.
    Feinglass, Joseph
    Barsuk, Jeffrey H.
    JOURNAL OF PATIENT SAFETY, 2022, 18 (03) : E697 - E703
  • [2] Central venous catheters as access for acute and long-term dialysis
    Hollenbeck, M.
    Niehuus, A.
    Wozniak, G.
    Hennigs, S.
    CHIRURG, 2012, 83 (09): : 801 - +
  • [3] Ultrasound-guided deep-arm veins insertion of long peripheral catheters in patients with difficult venous access after cardiac surgery
    Fabiani, Adam
    Dreas, Lorella
    Sanson, Gianfranco
    HEART & LUNG, 2017, 46 (01): : 46 - 53
  • [4] The longer the catheter, the lower the risk of complications: Results of the HERITAGE study comparing long peripheral and midline catheters
    Fabiani, Adam
    Aversana, Nicola
    Santoro, Marilena
    Calandrino, Dario
    Liotta, Paolo
    Sanson, Gianfranco
    AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (11) : 1289 - 1295
  • [5] Comparison of 12-cm versus 6-cm long peripheral catheters in patients with difficult intravenous access (DIVA)
    Pavelkova, Katerina
    Lisova, Katerina
    Blahova, Petra
    Mokra, Dana
    Hloch, Ondrej
    Charvat, Jiri
    JOURNAL OF VASCULAR ACCESS, 2022, 23 (01) : 94 - 97
  • [6] Central or Peripheral Catheters for Initial Venous Access of ICU Patients: A Randomized Controlled Trial
    Ricard, Jean-Damien
    Salomon, Laurence
    Boyer, Alexandre
    Thiery, Guillaume
    Meybeck, Agnes
    Roy, Carine
    Pasquet, Blandine
    Le Miere, Eric
    Dreyfuss, Didier
    CRITICAL CARE MEDICINE, 2013, 41 (09) : 2108 - 2115
  • [7] The catheter-to-vein ratio at the tip level, not the catheter type, as a risk factor for a catheter failure. A retrospective comparative study of polyurethane midline and long peripheral catheters
    Fabiani, Adam
    Santoro, Marilena
    Sanson, Gianfranco
    HEART & LUNG, 2023, 60 : 39 - 44
  • [8] The performance and complications of long peripheral venous catheters: A retrospective single-centre study
    Krath, Julie
    Fredskilde, Jesper
    Christensen, Simone Krogh
    Baltsen, Cecilie Dahl
    Valentin, Kamilla
    Offersen, Ryan
    Juhl-Olsen, Peter
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2024, 68 (10) : 1463 - 1470
  • [9] Contemporary Insertion of Central Venous Access Catheters in Pediatric Patients: A Retrospective Record Review Study of 538 Catheters in a Single Center
    van Gent, Max B.
    van der Made, Wendeline J.
    Marang-van de Mheen, Perla J.
    van der Bogt, Koen E.
    SURGICAL INFECTIONS, 2017, 18 (02) : 105 - 111
  • [10] Complications of long and intemiediate term venous catheters in cystic fibrosis patients: A multicenter study
    May, Teresa L.
    Gifford, Alex H.
    Lahiri, Thomas
    Black, Adam
    Trang, Janet
    Cornell, Alexandra G.
    Gonzalez, Karyll
    Morin, Scott
    Napier, Mark
    Duarte, Christine W.
    Zuckerman, Jonathan B.
    JOURNAL OF CYSTIC FIBROSIS, 2018, 17 (01) : 96 - 104