Improvement of separation performance by fluid motion in the membrane module with a helical baffle

被引:22
作者
Akagi, Takaaki [1 ]
Horie, Takafumi [1 ,2 ]
Masuda, Hayato [3 ]
Matsuda, Keigo [4 ]
Matsumoto, Hideyuki [5 ]
Ohmura, Naoto [1 ]
Hirata, Yushi [6 ]
机构
[1] Kobe Univ, Grad Sch Engn, Dept Chem Sci & Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Kobe Univ, Grad Sch Engn, Ctr Membrane & Film Technol, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[3] Univ Shizuoka, Sch Food & Nutr Sci, 52-1 Yada, Shizuoka 4228526, Japan
[4] Yamagata Univ, Grad Sch Sci & Engn, Dept Chem & Chem Engn, 4-3-16 Jonan, Yonezawa, Yamagata 9928510, Japan
[5] Natl Inst Adv Ind Sci & Technol, Renewable Energy Res Ctr, 2-2-9 Machiikedai, Koriyama, Fukushima 9630298, Japan
[6] Osaka Univ, Grad Sch Engn Sci, 1-3 Machikaneyama, Toyonaka, Osaka 5608531, Japan
关键词
Ultrafiltration; Water purification; Swirling flow; Helical coil; Process intensification; WIRE COIL INSERTS; CFD; FILTRATION; FLOW; SIMULATION; LAMINAR; WATER;
D O I
10.1016/j.seppur.2017.07.012
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Pressure-driven membrane filtration processes such as microfiltration and ultrafiltration are still hindered by concentration polarization and membrane fouling. Generally in these filtration processes, concentration polarization causes decline of permeate flux and rejection, and fouling leads to permeate flux decline with the increase of rejection. The use of high shear stress for cross flow filtrations has long been considered one of the most efficient methods for overcoming these problems. However, circumferential fluid motion of the hollow fiber membrane surface is also important to avoid formation of a high concentration layer on the surface. In this study, ultrafiltration of humic acid aqueous solution using a polyethersulfone hollow fiber membrane was selected as a model case, and a membrane module with a helical baffle installed around the membrane was used. With the insertion of the baffle, normalized permeate flux and rejection became higher than those without the baffle at the wide range of the feed flow rate. In order to identify the cause of the improvement, CFD simulation was conducted for different baffle geometries. Swirling flow motion generated by the helical baffle around the membrane became more dominant with the lower aperture ratio of the cross sectional area, and there existed the optimum value for the swirling flow generation in terms of the variation of the helical baffle pitch length. The intensity of this fluid motion was characterized by Swirl number and it was found out that high separation performance was obtained at the high Swirl number. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 50 条
  • [41] Performance improvement of continuous horizontal fluidised bed dryer based on computational fluid dynamics
    Handayani, Sri Utami
    Yohana, Eflita
    Tauviqirrahman, Mohammad
    Rahman, Aldian Ghani
    Yulianto, Mohamad Endy
    Choi, Kwang-Hwan
    RESULTS IN ENGINEERING, 2023, 17
  • [42] Design of membrane separation plants using a module data base
    Gunther, R
    Hapke, J
    DESALINATION, 1996, 104 (1-2) : 119 - 128
  • [43] Hydraulic optimization of membrane bioreactor via baffle modification using computational fluid dynamics
    Yan, Xiaoxu
    Xiao, Kang
    Liang, Shuai
    Lei, Ting
    Liang, Peng
    Xue, Tao
    Yu, Kaichang
    Guan, Jing
    Huang, Xia
    BIORESOURCE TECHNOLOGY, 2015, 175 : 633 - 637
  • [44] An analysis of performance on trisection helical baffles heat exchangers with diverse inclination angles and baffle structures
    Dong, Cong
    Zhou, Xin-Fa
    Dong, Rui
    Zheng, You-Qu
    Chen, Ya-Ping
    Hu, Gui-Lin
    Xu, You-Sheng
    Zhang, Zhi-Guo
    Guo, Wen-Wen
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 121 : 421 - 430
  • [45] Performance simulation on unilateral ladder type helical baffle heat exchanger in half cylindrical space
    Yang, Shifan
    Chen, Yaping
    Wu, Jiafeng
    Gu, Huaduo
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 134 - 147
  • [46] Unsteady-state membrane gas separation by novel pulsed retentate mode for improved membrane module performance: Modelling and experimental verification
    Trubyanov, Maxim M.
    Drozdov, Pavel N.
    Atlaskin, Artem A.
    Battalov, Stanislav V.
    Puzanov, Egor S.
    Vorotyntsev, Andrey V.
    Petukhov, Anton N.
    Vorotyntsev, Vladimir M.
    Vorotyntsev, Ilya V.
    JOURNAL OF MEMBRANE SCIENCE, 2017, 530 : 53 - 64
  • [47] Experimental simulation of membrane module performance in direct contact membrane distillation
    Okabe, Kazuhiro
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 172
  • [48] Membrane Module Design of Multieffect Plate Membrane Distillation and Computational Fluid Dynamics Simulation
    Zhao, Xiaoyue
    Wang, Xin
    Cheng, Fang
    Yuan, Hongying
    Wu, Zhi
    Jia, Weichen
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2024, 63 (12) : 5326 - 5338
  • [49] Multicomponent water-alcohol mixtures separation in helical membrane device
    Gorbenko, O.O.
    Doktorov, D.V.
    Trifonov, S.A.
    Mushtaev, V.I.
    Khimicheskoe I Neftegazovoe Mashinostroenie, 2002, (04): : 40 - 44
  • [50] THE EFFECT OF PTFE MEMBRANE PROPERTIES ON VACUUM MEMBRANE DISTILLATION MODULE PERFORMANCE
    Usta, Mustafa
    Krysko, Robert M.
    Anqi, Ali E.
    Alshwairekh, Ahmed M.
    Oztekin, Alparsian
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 7, 2019,