Response of liquid xenon to Compton electrons down to 1.5 keV

被引:34
|
作者
Baudis, L. [1 ]
Dujmovic, H. [1 ]
Geis, C. [1 ,2 ]
James, A. [1 ]
Kish, A. [1 ]
Manalaysay, A. [1 ]
Undagoitia, T. Marrodan [1 ]
Schumann, M. [1 ]
机构
[1] Univ Zurich, Inst Phys, CH-8057 Zurich, Switzerland
[2] Tech Hsch Mittelhessen, Friedberg, Germany
来源
PHYSICAL REVIEW D | 2013年 / 87卷 / 11期
基金
瑞士国家科学基金会;
关键词
DARK-MATTER; DETECTORS; ENERGY; ARGON;
D O I
10.1103/PhysRevD.87.115015
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axionlike particles, as opposed to weakly interacting massive particles which are predicted to scatter with atomic nuclei. Recently, liquid-xenon scintillation light has been observed from electronic recoils down to 2.1 keV, but without applied electric fields that are used in most xenon dark-matter searches. Applied electric fields can reduce the scintillation yield by hindering the electron-ion recombination process that produces most of the scintillation photons. We present new results of liquid xenon's scintillation emission in response to electronic recoils as low as 1.5 keV, with and without an applied electric field. At zero field, a reduced scintillation output per unit deposited energy is observed below 10 keV, dropping to nearly 40% of its value at higher energies. With an applied electric field of 450 V/cm, we observe a reduction of the scintillation output to about 75% relative to the value at zero field. We see no significant energy dependence of this value between 1.5 and 7.8 keV. With these results, we estimate the electronic-recoil energy thresholds of ZEPLIN-III, XENON10, XENON100, and XMASS to be 2.8, 2.5, 2.3, and 1.1 keV, respectively, validating their excellent sensitivity to low-energy electronic recoils.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Detection of energy deposition down to the keV region using liquid xenon scintillation
    Benetti, P.
    Calligarich, E.
    Dolfini, R.
    Gigli Berzolari, A.
    Mauri, F.
    Mazzone, L.
    Montanari, C.
    Piazzoli, A.
    Rappoldi, A.
    Raselli, G.L.
    Scannicchio, D.
    Bettini, A.
    Casagrande, F.
    Casoli, P.
    Centro, S.
    Dainese, B.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A327 (01) : 203 - 206
  • [2] DETECTION OF ENERGY DEPOSITION DOWN TO THE KEV REGION USING LIQUID XENON SCINTILLATION
    BENETTI, P
    CALLIGARICH, E
    DOLFINI, R
    BERZOLARI, AG
    MAURI, F
    MAZZONE, L
    MONTANARI, C
    PIAZZOLI, A
    RAPPOLDI, A
    RASELLI, GL
    SCANNICCHIO, D
    BETTINI, A
    CASAGRANDE, F
    CASOLI, P
    CENTRO, S
    DAINESE, B
    DEVECCHI, C
    GASPARINI, F
    MURATORI, G
    PEPATO, A
    PIETROPAOLO, F
    ROSSI, P
    SUZUKI, S
    VENTURA, S
    CASTAGNOLI, C
    MANNOCCHI, G
    PERIALE, L
    CAVANNA, F
    MORTARI, GP
    CENNINI, P
    CITTOLIN, S
    RUBBIA, C
    CHENG, M
    CLINE, D
    OTWINOWSKI, S
    ZHOU, M
    FORTSON, L
    PICCHI, P
    WANG, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (01): : 203 - 206
  • [3] Scintillation efficiency of liquid xenon for nuclear recoils with the energy down to 5 keV
    Chepel, V.
    Solovov, V.
    Neves, F.
    Pereira, A.
    Mendes, P. J.
    Silva, C. P.
    Lindote, A.
    da Cunha, J. Pinto
    Lopes, M. I.
    Kossionides, S.
    ASTROPARTICLE PHYSICS, 2006, 26 (01) : 58 - 63
  • [4] Scintillation efficiency and ionization yield of liquid xenon for monoenergetic nuclear recoils down to 4 keV
    Manzur, A.
    Curioni, A.
    Kastens, L.
    McKinsey, D. N.
    Ni, K.
    Wongjirad, T.
    PHYSICAL REVIEW C, 2010, 81 (02):
  • [5] MPGDs in Compton imaging with liquid-xenon
    Duval, S.
    Breskin, A.
    Carduner, H.
    Cussonneau, J. -P.
    Lamblin, J.
    Le Ray, P.
    Morteau, E.
    Oger, T.
    Stutzmann, J. -S.
    Thers, D.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [6] Simulation of Compton reconstruction in liquid xenon PET
    Bryman, Douglas
    Kurchaninov, Leonid
    Lu, Philip
    Retiere, Fabriece
    Sossi, Vesna
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4419 - +
  • [7] XEMIS : A new Compton camera with liquid xenon
    Masbou, J.
    Cussonneau, J. -P.
    Donnard, J.
    Manzano, L. Gallego
    Leray, O. Lemaire P.
    Hadi, A. -F. Mohamed
    Morteau, E.
    Lavina, L. Scotto
    Stutzmann, J. -S.
    Thers, D.
    Bassetto, S.
    Briend, P.
    Gorski, M.
    Beaupere, N.
    Carlier, T.
    Cherel, M.
    Kraeber-Bodere, F.
    PROCEEDINGS OF THE 2014 IEEE 18TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL 2014), 2014,
  • [8] A Compton coincidence study of liquid scintillator response to low-energy electrons
    Peron, MN
    Cassette, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 344 - 347
  • [9] COMPTON DEFECT IN AMMONIA AS OBSERVED USING 35 KEV INCIDENT ELECTRONS
    LAHMAMBENNANI, A
    DUGUET, A
    WELLENSTEIN, HF
    CHEMICAL PHYSICS LETTERS, 1979, 60 (03) : 411 - 413
  • [10] A liquid xenon TPC for a medical imaging Compton telescope
    Oger, T.
    Chen, W. -T.
    Cussonneau, J. -P.
    Donnard, J.
    Duval, S.
    Lamblin, J.
    Lemaire, O.
    Hadi, A. F. Mohamad
    Leray, P.
    Morteau, E.
    Lavina, L. Scotto
    Stutzmann, J. -S.
    Thers, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 125 - 128