Pulmonary arterial resistance: Noninvasive measurement with indexes of pulmonary flow estimated at velocity-encoded MR imaging - Preliminary experience

被引:89
|
作者
Mousseaux, E
Tasu, JP
Jolivet, O
Simonneau, G
Bittoun, J
Gaux, JC
机构
[1] Hop Broussais, Dept Cardiovasc Radiol, F-75014 Paris, France
[2] CHU Pitie Salpetriere, INSERM, U494, Paris, France
[3] Hop Bicetre, Ctr Luter Etab Resonance Magnet, CNRS, URA 2212, Le Kremlin Bicetre, France
[4] Hop Antoine Beclere, Dept Resp Dis, Clamart, France
关键词
hypertension; pulmonary; magnetic resonance (MR); phase imaging; pulmonary arteries; abnormalities; flow dynamics;
D O I
10.1148/radiology.212.3.r99au21896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac output and pulmonary vascular resistance (PVR) were measured in 19 patients by means of catheterization of the right side of the heart. Results were compared with the cardiac output and indexes of pulmonary arterial blood flow estimated with velocity-encoded magnetic resonance (MR) imaging. Correlations were good between estimates with right-sided heart catheterization and those with velocity-encoded MR imaging. By providing accurate pulmonary arterial blood flow measurements, velocity-encoded MR imaging allowed distinction of patients with high PVR from subjects with normal PVR.
引用
收藏
页码:896 / 902
页数:7
相关论文
共 15 条
  • [1] PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING
    KONDO, C
    CAPUTO, GR
    MASUI, T
    FOSTER, E
    OSULLIVAN, M
    STULBARG, MS
    GOLDEN, J
    CATTERJEE, K
    HIGGINS, CB
    RADIOLOGY, 1992, 183 (03) : 751 - 758
  • [2] Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
    Sakuma, H
    Blake, LM
    Amidon, TM
    OSullivan, M
    Szolar, DH
    Furber, AP
    Bernstein, MA
    Foo, TKF
    Higgins, CB
    RADIOLOGY, 1996, 198 (03) : 745 - 750
  • [3] Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
    Varaprasathan, GA
    Araoz, PA
    Higgins, CB
    Reddy, GP
    RADIOGRAPHICS, 2002, 22 (04) : 895 - 905
  • [4] Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Arheden, H
    Ståhlberg, F
    Higgins, CB
    Saeed, M
    RADIOLOGY, 2000, 217 (02) : 487 - 493
  • [5] Assessment of Pulmonary Arterial Pressure by Velocity-Encoded Cine Magnetic Resonance Imaging in Children With Congenital Heart Disease
    Sugimoto, Masaya
    Kajino, Hiroki
    Kajihama, Aya
    Nakau, Kouichi
    Murakami, Noboru
    Azuma, Hiroshi
    CIRCULATION JOURNAL, 2013, 77 (12) : 3015 - 3022
  • [6] COMPARISON OF VELOCITY-ENCODED MR IMAGING AND FLUID DYNAMIC MODELING OF STEADY AND DISTURBED FLOW
    SUN, Y
    HEARSHEN, DO
    RANKIN, GW
    HAGGAR, AM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 443 - 452
  • [7] 3-DIMENSIONAL MR IMAGING OF THE PULMONARY VASCULATURE - PRELIMINARY EXPERIENCE
    WIELOPOLSKI, PA
    HAACKE, EM
    ADLER, LP
    RADIOLOGY, 1992, 183 (02) : 465 - 472
  • [8] PULMONARY ANGIOGRAPHY WITH MR-IMAGING - PRELIMINARY CLINICAL-EXPERIENCE
    GRIST, TM
    SOSTMAN, HD
    MACFALL, JR
    FOO, TK
    SPRITZER, CE
    WITTY, L
    NEWMAN, GE
    DEBATIN, JF
    TAPSON, V
    SALTZMAN, HA
    RADIOLOGY, 1993, 189 (02) : 523 - 530
  • [9] FLOW PATTERN-ANALYSIS IN THE ABDOMINAL-AORTA WITH VELOCITY-ENCODED CINE MR-IMAGING
    MOSTBECK, GH
    DULCE, MC
    CAPUTO, GR
    PROCTOR, E
    HIGGINS, CB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 617 - 623
  • [10] Chronic heart failure: Global left ventricular perfusion and coronary flow reserve with velocity-encoded cine MR imaging: Initial results
    Lund, GK
    Watzinger, N
    Saeed, M
    Reddy, GP
    Yang, M
    Araoz, PA
    Curatola, D
    Bedigian, M
    Higgins, CB
    RADIOLOGY, 2003, 227 (01) : 209 - 215