Comparison of Intraocular Pressure Measurements between Icare Pro Rebound Tonometer and Tono-Pen XL Tonometer in Supine and Lateral Decubitus Body Positions

被引:9
作者
Lee, Tae-Eun [1 ]
Yoo, Chungkwon [1 ]
Hwang, Jin-Young [1 ]
Lin, Shan [2 ]
Kim, Yong Yeon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Ophthalmol, Seoul 136705, South Korea
[2] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
关键词
Body position; Icare tonometer; intraocular pressure; lateral decubitus; rebound tonometer; supine; tono-pen tonometer; CENTRAL CORNEAL THICKNESS; CURVATURE;
D O I
10.3109/02713683.2014.964416
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare intraocular pressure (IOP) measurements obtained using the Icare Pro rebound tonometer and Tono-Pen XL tonometer in supine and lateral decubitus body positions. Methods: One-hundred eyes of 50 subjects (normal volunteers or glaucoma suspects) were enrolled in this prospective observational study. IOP was measured in both eyes using the Icare Pro and Tono-Pen XL in the sitting position and the recumbent positions including supine, right lateral decubitus and left lateral decubitus. IOP was measured five minutes after assuming each of the recumbent postures in a randomized sequence. The eye on the lower side in the lateral decubitus position was termed as the dependent eye. Agreement of IOP readings between the Icare Pro and Tono-Pen was assessed in all recumbent positions. Differences of IOP readings (Delta IOP) between the two tonometers and their correlations with ocular parameters were also assessed in all positions. Results: The IOP readings obtained using Icare Pro and Tono-Pen showed good correlations in supine and lateral decubitus positions (all r>0.7, p<0.005), although Icare Pro readings were higher than Tono-Pen readings (all p<0.001) in all positions. The DIOP showed a weakly positive correlation with central corneal thickness in both eyes, whereas such a positive correlation was found only in the dependent eye in the lateral decubitus positions (r=0.307-0.531, all p<0.005). Both the spherical equivalents and axial lengths were not correlated with Delta IOP in all positions. Conclusion: IOP readings obtained with Tono-Pen and Icare Pro tonometers showed good agreement in supine as well as in lateral decubitus positions, although Icare readings were higher than Tono-Pen readings in all positions. Such differences in IOP readings between the different tonometers need to be considered when measuring IOPs in various body positions.
引用
收藏
页码:923 / 929
页数:7
相关论文
共 43 条
[21]   Intradevice and Interdevice Agreement Between a Rebound Tonometer, Icare PRO, and the Tonopen XL and Kowa Hand-held Applanation Tonometer When Used in the Sitting and Supine Position [J].
Nakakura, Shunsuke ;
Mori, Etsuko ;
Yamamoto, Minami ;
Tsushima, Yuuri ;
Tabuchi, Hitoshi ;
Kiuchi, Yoshiaki .
JOURNAL OF GLAUCOMA, 2015, 24 (07) :515-521
[22]   Agreement between diurnal variations of intraocular pressure by Tono-Pen and Goldmann applanation tonometer in patients on topical anti-glaucoma medication [J].
Gupta, Shikha ;
Sinha, Gautam ;
Sharma, Reetika ;
Nayak, Bhagabat ;
Patil, Bharat ;
Kashyap, Bibhuti ;
Shameer, Abdul ;
Dada, Tanuj .
INTERNATIONAL OPHTHALMOLOGY, 2016, 36 (01) :9-15
[23]   Agreement between diurnal variations of intraocular pressure by Tono-Pen and Goldmann applanation tonometer in patients on topical anti-glaucoma medication [J].
Shikha Gupta ;
Gautam Sinha ;
Reetika Sharma ;
Bhagabat Nayak ;
Bharat Patil ;
Bibhuti Kashyap ;
Abdul Shameer ;
Tanuj Dada .
International Ophthalmology, 2016, 36 :9-15
[24]   Comparison of the Intraocular Pressure Measured Using the New Rebound Tonometer Icare ic100 and Icare TA01i or Goldmann Applanation Tonometer [J].
Nakakura, Shunsuke ;
Mori, Etsuko ;
Fujio, Yuki ;
Fujisawa, Yasuko ;
Matsuya, Kanae ;
Kobayashi, Yui ;
Tabuchi, Hitoshi ;
Asaoka, Ryo ;
Kiuchi, Yoshiaki .
JOURNAL OF GLAUCOMA, 2019, 28 (02) :172-177
[25]   Intraocular pressure measurement using ICare rebound tonometer in different positions of eye and different locations on cornea [J].
Wongwanwatana, Sirada ;
Treesit, Isaraporn ;
Funarunart, Panrapee ;
Iemsomboon, Wallop ;
Choontanom, Raveewan .
MEDICINE, 2023, 102 (36) :E34874
[26]   Intraocular pressure measurements with the Tono-Pen XL® and Perkins® applanation tonometers in horses and cattle [J].
Andrade, Silvia Franco ;
Palozzi, Rodrigo de Jesus ;
Rolim, Rodrigo Duarte ;
Cecilio Junqueira, Jose Ricardo ;
do Valle, Heloisa Ferreira ;
da Silva, Marcelo Kurak ;
Maia, Marcelo Augusto ;
Zampiere, Rodrigo Augusto .
CIENCIA RURAL, 2013, 43 (05) :865-870
[27]   Comparison of intraocular pressure in healthy brachycephalic and nonbrachycephalic cats using the Icare® TONOVET Plus rebound tonometer [J].
Kerdchuchuen, Kamolchanok ;
Samathayanon, Kingkarn ;
Phientong, Pitchapa ;
Chattraphirat, Suprapha ;
Jaturakan, Orapun ;
Tuntivanich, Nalinee .
VETERINARY OPHTHALMOLOGY, 2021, 24 (05) :484-490
[28]   A comparison of postural and diurnal variations in intraocular pressure using the iCare rebound tonometer and Perkins applanation tonometer in admitted adults in Kenya [J].
Chikasirimobi, Timothy G. ;
Ndinyo, Mercy ;
Ondieki, Maxine N. ;
Miti, Isaac ;
Ejiochi-Iyoke, Ndidi J. ;
Osuagwu, Uchechukwu L. ;
Zeried, Ferial M. ;
Agho, Kingsley ;
Ogbuehi, Kelechi C. ;
Mashige, Khathutshelo P. .
AFRICAN VISION AND EYE HEALTH JOURNAL, 2021, 80 (01)
[29]   Comparison of Intraocular Pressures at Different Points in Human's Cornea before and after Laser in situ Keratomileusis with Tono-Pen Tonometer [J].
李新宇 ;
李贵刚 ;
刘磊 ;
栗静 .
Current Medical Science, 2011, (01) :128-130
[30]   Comparison of Intraocular Pressure Measurements with Goldmann Applanation Tonometry, iCare, and Tono-Pen in Young Children with Anterior Segment Abnormalities Under General Anesthesia [J].
Studer, Matias K. ;
Iliev, Milko ;
Tappeiner, Christoph ;
Frueh, Beatrice E. ;
Fraenkl, Stephan A. .
JOURNAL OF CLINICAL MEDICINE, 2025, 14 (10)