Itemizing the bundle: Achieving and maintaining "zero" central line-associated bloodstream infection for over a year in a tertiary care hospital in Saudi Arabia

被引:0
|
作者
Khalid, Imran [1 ]
Al Salmi, Hanadi [2 ]
Qushmaq, Ismael [1 ]
Al Hroub, Mohammed [2 ]
Kadri, Mazen [1 ]
Qabajah, Mohammad R. [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Med, Jeddah, Saudi Arabia
[2] King Faisal Specialist Hosp & Res Ctr, Dept Infect Control, Jeddah, Saudi Arabia
关键词
CLABSI; Zero; Intensive care unit; Asia; UNITS; RATES; SURVEILLANCE; MICHIGAN; IMPACT; RISK;
D O I
10.1016/j.ajic.2013.05.028
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: "Zero" central line-associated bloodstream infections (CLABSI) have not been reported from Asian countries, which usually have predominance of difficult to curtail gram negative infections. It also remains unclear whether lowering CLABSI rates below National Healthcare Safety Network (NHSN) benchmarks in such countries is even possible. In this study, we evaluated effects of a quality improvement initiative to achieve "Zero CLABSI" in our intensive care unit. Methods: A root cause analysis in February 2010 identified problems with clinical practice, environment, and products. Extensive education sessions were followed by implementation of strategies in the form of "itemized" bundles derived from practice guidelines, with complete enforcement starting August 2010. Results were benchmarked against NHSN data. Data were analyzed in a preintervention (1 year) and postintervention (2 years) fashion, using Poisson regression analysis to generate incidence-rate ratio (IRR). Results: In the preintervention period, CLABSI rate was 6.9/1,000 catheter-days (CDs) (35 CLABSI/5,083 CDs). In the postintervention year 1, rate was 1.06/1,000 CDs (4 CLABSI/3,787 CDs) with IRR of 0.15 (95% confidence interval: 0.04-0.44, P < .001) and reduction of 85%. In postintervention year 2, rate was 0.35/1,000 CDs (1/2,860 CDs) with IRR of 0.05 (95% confidence interval: 0.001-0.31, P < .001). There was a period of "Zero CLABSI" for 15 consecutive months, surpassing NHSN benchmarks. Conclusion: : CLABSIs can be eliminated in any intensive care unit regardless of the location and type of organism. NHSN data should be a realistic CLABSI benchmarking target for developing countries. Copyright (C) 2013 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1209 / 1213
页数:5
相关论文
共 50 条
  • [1] Assessing the effect of implementing a central line care bundle on central line-associated bloodstream infections in a tertiary hospital in Saudi Arabia
    Alhumaidan, Ohoud
    Alkudmani, Zeina
    Alnafee, Khaled
    Alshuhri, Sabah
    Alrashid, Bandar
    Alkahtany, Jalwa
    Almazrua, Afnan
    Alghamdi, Salem
    ITALIAN JOURNAL OF MEDICINE, 2024, 18 (04)
  • [2] Length of Stay in Patients With Central Line-Associated Bloodstream Infection at a Tertiary Hospital in the Kingdom of Saudi Arabia
    Alotaibi, Naif H.
    Barri, Abdulrahman
    Elahi, Muhammad A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [3] Risk of central line-associated bloodstream infections during COVID-19 pandemic in intensive care patients in a tertiary care centre in Saudi Arabia
    Alshamrani, Majid M.
    El-Saed, Aiman
    Aldayhani, Omar
    Alhassan, Abdulaziz
    Alhamoudi, Abdullah
    Alsultan, Mohammed
    Alrasheed, Mohammed
    Othman, Fatmah
    EPIDEMIOLOGY & INFECTION, 2024, 152
  • [4] Achieving Zero Central Line-associated Bloodstream Infection Rates in Your Intensive Care Unit
    Sagana, Rommel
    Hyzy, Robert C.
    CRITICAL CARE CLINICS, 2013, 29 (01) : 1 - +
  • [5] Incidence of Central Line-Associated Bloodstream Infection in a Tertiary Care Hospital in Northern India: A Prospective Study
    Maqbool, Safia
    Sharma, Rajni
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [6] Achieving a Zero Central Line-Associated Bloodstream Infection Rate in 4 Critical Care Units in Lebanon
    Jamous, Sabath
    Kouatly, Iman
    Zaatari, Rafika
    Badr, Lina Kurdahi
    JOURNAL OF INFUSION NURSING, 2019, 42 (05) : 249 - 253
  • [7] Beyond the bundle - journey of a tertiary care medical intensive care unit to zero central line-associated bloodstream infections
    Exline, Matthew C.
    Ali, Naeem A.
    Zikri, Nancy
    Mangino, Julie E.
    Torrence, Kelly
    Vermillion, Brenda
    St Clair, Jamie
    Lustberg, Mark E.
    Pancholi, Preeti
    Sopirala, Madhuri M.
    CRITICAL CARE, 2013, 17 (02):
  • [8] Effectiveness of a care bundle to reduce central line-associated bloodstream infections
    Entesari-Tatafi, Damoon
    Orford, Neil
    Bailey, Michael J.
    Chonghaile, Martina N. I.
    Lamb-Jenkins, Jill
    Athan, Eugene
    MEDICAL JOURNAL OF AUSTRALIA, 2015, 202 (05) : 247 - +
  • [9] The impact of central line insertion bundle on central line-associated bloodstream infection
    Tang, Hung-Jen
    Lin, Hsin-Lan
    Lin, Yu-Hsiu
    Leung, Pak-On
    Chuang, Yin-Ching
    Lai, Chih-Cheng
    BMC INFECTIOUS DISEASES, 2014, 14
  • [10] Central line-associated bloodstream infections among critically-ill patients in the era of bundle care
    Lin, Kuan-Yin
    Cheng, Aristine
    Chang, Yu-Ching
    Hung, Mei-Chuan
    Wang, Jann-Tay
    Sheng, Wang-Huei
    Hseuh, Po-Ren
    Chen, Yee-Chun
    Chang, Shan-Chwen
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2017, 50 (03) : 339 - 348