Pure component selectivity analysis of multivariate calibration models from near-infrared spectra

被引:36
|
作者
Arnold, MA [1 ]
Small, GW
Xiang, D
Qui, J
Murhammer, DW
机构
[1] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Chem & Biochem Engn, Iowa City, IA 52242 USA
[4] Ohio Univ, Ctr Intelligent Chem Insttumentat, Athens, OH 45701 USA
[5] Ohio Univ, Dept Chem & Biochem, Clippinger Labs, Athens, OH 45701 USA
关键词
D O I
10.1021/ac035516q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.
引用
收藏
页码:2583 / 2590
页数:8
相关论文
共 50 条
  • [41] Quality control of pharmaceutical aspirin powder by near-infrared reflectance spectra and multivariate analysis
    Ren, YL
    Zhang, ZY
    Ren, YQ
    Li, W
    Liu, SD
    SPECTROSCOPY LETTERS, 1997, 30 (08) : 1699 - 1711
  • [42] Application of principal component analysis in calibration sample selection of near-infrared quantitative model
    Li Yan-Zhou
    Min Shun-Geng
    Liu Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (09) : 1331 - 1334
  • [43] Ensemble of extreme learning machines for multivariate calibration of near-infrared spectroscopy
    Chen, Hui
    Tan, Chao
    Lin, Zan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 229
  • [44] Optical coefficient-based multivariate calibration on near-infrared spectroscopy
    Shi, Zhenqi
    Cogdill, Robert P.
    Martens, Harald
    Anderson, Carl A.
    JOURNAL OF CHEMOMETRICS, 2010, 24 (5-6) : 288 - 299
  • [45] CLASSIFICATION OF BRAZILIAN COFFEE USING NEAR-INFRARED SPECTROSCOPY AND MULTIVARIATE CALIBRATION
    Santos, Klecia M.
    Moura, Maria F. V.
    Azevedo, Francisco G.
    Lima, Kassio M. G.
    Raimundo, Ivo M., Jr.
    Pasquini, C.
    ANALYTICAL LETTERS, 2012, 45 (07) : 774 - 781
  • [46] An adaptive wavelet algorithm used to multivariate calibration of near infrared spectra
    Wu, RH
    Shao, XG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 1010 - 1012
  • [47] A new ensemble modeling method for multivariate calibration of near infrared spectra
    Wang, Kaiyi
    Bian, Xihui
    Tan, Xiaoyao
    Wang, Haitao
    Li, Yankun
    ANALYTICAL METHODS, 2021, 13 (11) : 1374 - 1380
  • [48] Mineralogical analysis of the Eos family from near-infrared spectra
    Mothe-Diniz, T.
    Carvano, J. M.
    Bus, S. J.
    Duffard, R.
    Burbine, T. H.
    ICARUS, 2008, 195 (01) : 277 - 294
  • [49] Multivariate calibration methods in near infrared spectroscopic analysis
    Shao, Xueguang
    Bian, Xihui
    Liu, Jingjing
    Zhang, Min
    Cai, Wensheng
    ANALYTICAL METHODS, 2010, 2 (11) : 1662 - 1666
  • [50] Accurate wavelength calibration in the near-infrared for multielement analysis without the need for reference spectra
    Asimellis, George
    Giannoudakos, Aggelos
    Kompitsas, Michael
    APPLIED OPTICS, 2006, 45 (35) : 8855 - 8862