Pure component selectivity analysis of multivariate calibration models from near-infrared spectra

被引:36
|
作者
Arnold, MA [1 ]
Small, GW
Xiang, D
Qui, J
Murhammer, DW
机构
[1] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Chem & Biochem Engn, Iowa City, IA 52242 USA
[4] Ohio Univ, Ctr Intelligent Chem Insttumentat, Athens, OH 45701 USA
[5] Ohio Univ, Dept Chem & Biochem, Clippinger Labs, Athens, OH 45701 USA
关键词
D O I
10.1021/ac035516q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.
引用
收藏
页码:2583 / 2590
页数:8
相关论文
共 50 条
  • [31] A weighted multiscale regression for multivariate calibration of near infrared spectra
    Liu, Zhichao
    Cai, Wensheng
    Shao, Xueguang
    ANALYST, 2009, 134 (02) : 261 - 266
  • [32] Application of Fourier transform to multivariate calibration of near-infrared data
    Pasti, L
    Jouan-Rimbaud, D
    Massart, DL
    de Noord, OE
    ANALYTICA CHIMICA ACTA, 1998, 364 (1-3) : 253 - 263
  • [34] Calibration model transfer for near-infrared spectra based on canonical correlation analysis
    Fan, Wei
    Liang, Yizeng
    Yuan, Dalin
    Wang, Jiajun
    ANALYTICA CHIMICA ACTA, 2008, 623 (01) : 22 - 29
  • [35] Multivariate calibration of on-line enrichment near-infrared (NIR) spectra and determination of trace lead in water
    Huang, Zixia
    Tao, Wei
    Fang, Juanjuan
    Wei, Xuemei
    Du, Yiping
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2009, 98 (02) : 195 - 200
  • [36] Alleviating the Effects of Light Scattering in Multivariate Calibration of Near-Infrared Spectra by Path Length Distribution Correction
    Leger, Marc N.
    APPLIED SPECTROSCOPY, 2010, 64 (03) : 245 - 254
  • [37] PREDICTION OF FORAGE DIGESTIBILITY BY PRINCIPAL COMPONENT ANALYSIS OF NEAR-INFRARED REFLECTANCE SPECTRA
    ROBERT, P
    BERTRAND, D
    DEMARQUILLY, C
    ANIMAL FEED SCIENCE AND TECHNOLOGY, 1986, 16 (03) : 215 - 224
  • [38] Principal component analysis of near-infrared spectra of alteration products in calcareous samples
    Bacci, M
    Porcinai, S
    Radicati, B
    APPLIED SPECTROSCOPY, 1997, 51 (05) : 700 - 706
  • [39] Net Analyte Signal Calculation in Near-Infrared Spectra Calibration
    Liu, Weiling
    Liu, Libing
    Yu, Qilian
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 205 - +
  • [40] Spectral simulation methodology for calibration transfer of near-infrared spectra
    Sulub, Yusuf
    Small, Gary W.
    APPLIED SPECTROSCOPY, 2007, 61 (04) : 406 - 413